Ethernet Ports

Two Ethernet ports are located next to USB0/1 on the IO backplane. In addition, an IPMI Dedicated LAN is located above USB0/1. These ports accept RJ45 type cables. See the table on the right for pin definitions.

Note 1: Please refer to the LED Indicator Section for LAN LED information.

LAN Ports

Pin Definitions

Pin#

Definition

Pin#

Definition

1

P2V5SB

10

SGND

2

TD0+

11

Act LED

3

TD0-

12

P3V3SB

4

TD1+

13

Link 100 LED

 

 

 

(Yellow, +3V3SB)

5

TD1-

14

Link 1000 LED

 

 

 

(Yellow, +3V3SB)

6

TD2+

15

Ground

7

TD2-

16

Ground

8

TD3+

17

Ground

9

TD3-

88

Ground

(NC: No Connection)

InfiniBand Connection (X8DTT-HIBXF+/ HIBQF+)

InfiniBand

Pin Definitions

The onboard InfiniBand connector is located on the backplane on the serverboard. This switch is primarily used for High-performance computing. See the table on the right for pin definitions.

S2 S3

S5

S7

S10 S11 S12 S13 S14

S15 S16

S1

S4

S6

S8 S9

 

G1

G2

G3

G4

G5

G6

G7

G8

G9

Pin # Definition

S1 Input

Pair0:Pos

S2 Input

Pair0:Neg

S3 Input

Pair1:Pos

S4 Input Pair1:Neg

S5 Input

Pair2:Pos

S6 Input

Pair2:Neg

S7 Input

Pair3:Pos

S8 Input

Pair3:Neg

Pin # Definition

S9 Output

Pair3:Pos

S10 Output

Pair3:Neg

S11 Output

Pair2:Pos

S12 Output

Pair2:Neg

S13 Output

Pair1:Pos

S14 Output

Pair1:Neg

S15 Output

Pair0:Pos

S16 Output

Pair0:Neg

InfiniBand Ground Pins (G1~G9) Pin Definitions

Pin# Definitions

G1~G9

Ground

 

 

5-14

Image 48
Contents Super Manual Revision Release Date November 16 Preface About This ManualManual Organization System Safety Advanced Serverboard SetupAdvanced Chassis Setup BiosPreface Table of Contents System Interface Appendix a Bios Error Beep Codes Chapter Introduction OverviewServerboard Features Processors MemorySerial ATA PCI Expansion SlotsOther Features Onboard Controllers/PortsGraphics Controller InfiniBandIntel 5520 Chipset System Block Diagram Server Chassis Features 2U Twin System Notes GPU SubsystemNodes Sata Backplane/DrivesContacting Supermicro HeadquartersEurope Asia-PacificPage Chapter Server Installation Preparing for SetupUnpacking the System Choosing a Setup Location Ambient Operating Temperature Rack Mounting ConsiderationsRemoving the Protective Film Removing the Protective FilmRail Assembly Rack Mounting InstructionsSeparating the Sections of the Rack Rails Separating the Inner and Outer RailsInstalling the Inner Rail Extensions Installing the Inner RailsInstalling the Outer Rails to the Rack Outer Rack RailsInstalling Into the Rack Installing the Chassis into a RackChecking the Serverboard Setup Accessing the Inside of a Node FigureChecking the Components and Setup Preparing to Power On Providing PowerChecking the Sata drives Checking the AirflowRemoving a Node from the System Page Power Chapter System InterfaceControl Panel Buttons Control Panel LEDs Sata Drive Carrier LEDsOverheat/Fan Fail Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup Handling the ServerboardI/O Ports I/O PortsProcessor and Heatsink Installation Installing LGA1366 ProcessorsCPU Installing a CPU Heatsink Removing the Heatsink Installing Memory Installing Memory ModulesMemory Support Dimm Installation Notch Front ViewPCI Card Installation Adding PCI CardsPCI Express Slot Serverboard Details LE2Connector Description Serverboard Quick ReferenceJumper Description Connector Definitions Front Panel Accessible Add-on Card Header JF2NMI Header Internal BuzzerVideo Connector Fan HeaderUniversal Serial Bus USB Ethernet Ports InfiniBand Connection X8DTT-HIBXF+/ HIBQF+System Reset Unit Identifier SwitchesSerial Ports Jumper Settings Cmos ClearTo Clear Cmos LAN1/LAN2 Enable/Disable Watch Dog Enable/DisableVGA Enable/Disable Onboard Indicators InfiniBand LED Indicators LEB1/LEB2Onboard Power LED LAN1/LAN2 LEDsSerial ATA Ports BMC Activity LED LE2Rear UID LED LE4 Serial ATA ConnectionsInstalling Additional Drivers 12 Configuring Supero Doctor Page Chapter Advanced Chassis Setup Control Panel System FansFan Configuration System Fan FailureChanging a System Fan Hard Drive Installation/Removal Installing and Removing Hard DrivesInstalling a Hard Drive into the Drive Carrier OverviewInstalling/Removing Hot-swap Drives Removing a Dummy Drive TrayNode a Node B Node Installation/Removal Removing a NodeRemoving a System Node Installing the Air Shrouds Power SupplyInstalling an Air Shroud Removing/Replacing the Power Supply FigureRemoving the Power Supply Release Tab Starting Bios Setup Utility How To Change the Configuration DataChapter IntroductionMain Setup Starting the Setup UtilitySystem Overview System Time/System DateBios Build Date AMI Bios Core VersionProcessor CPU TypeAdvanced Setup Configurations Xboot FeaturesXPower Configuration XProcessor and Clock OptionsHardware Prefetcher Available when supported by the CPU C1E SupportActive Processor Cores Intel Eist TechnologyXAdvanced Chipset Control Xcpu Bridge ConfigurationMemory Mode Memory ECC Error ThresholdQPI L0s and L1 Memory FrequencyHysteresis Temperature Guardband TemperatureInlet Temperature Temperature RiseXNorth Bridge Configuration XSouthBridge ConfigurationXIDE/SATA Configuration LBA/Large Mode PIO ModeSATA#2 Configuration TypeDMA Mode XPCI/PnP Configuration XRemote Access Configuration XSuper IO Device ConfigurationSredir Memory Display Delay CPU Overheat AlarmXHardware Health Monitor Terminal TypeCPU Temperature/System Temperature CPU TemperatureAcpi Version Features Acpi Apic Support Xacpi ConfigurationFan Speed Control Monitor Fan1 ~ Fan 4 ReadingXGeneral Whea Configuration Xipmi Configuration X8DTT-HF/-HIBXF/-HIBQF OnlyXView BMC System Event Log XSet LAN ConfigurationXIP Address Configuration Parameter SelectorXmac Address Configuration XSubnet Mask ConfigurationXGateway Address Configuration Subnet MaskCurrent Subnet Mask in BMC Gateway AddressSecurity Settings Xdmi Event LogBoot Configuration XBoot Device PriorityPassword Check Boot Sector Virus ProtectionXHard Disk Drives XRemovable DrivesXCD/DVD Drives Bios Recovery Exit OptionsHow to Recover the Amibios Image the Main Bios Block Boot Sector Recovery from a USB DeviceBoot Sector Recovery from a Serial Port Serial Flash How to use Serial Flash for Boot Sector RecoveryPage Page Appendix a Bios Error Beep Codes Bios Error Beep CodesBios Error Beep Codes Page Appendix B Installing Windows Installing Windows for a RAID SystemInstalling Windows for a Non-RAID System Bios Appendix C System SpecificationsChassis Regulatory Compliance