Seagate ST19171N, ST19171DC, ST19171WD, ST19171WC manual Other applicable jumper options

Page 37

Barracuda 9 Installation Guide, Rev. B

35

N drives

Other applicable jumper options

Several other jumper options are available as illustrated.

Drive with

 

 

 

 

 

 

 

 

 

HDA up, PCB

 

 

 

 

 

 

 

 

 

down, viewed

 

 

 

 

Pin 1

from front

HDA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J6

 

 

 

 

 

 

 

 

 

 

 

 

L

R

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved E

E

E A

2

A

1

A

0

 

 

 

D

S

S

 

 

 

J2

Reserved

Delay Motor Start option (valid only if the Enable Motor Start jumper is not connected)

Pin 1

Reserved

 

 

11

 

 

Remote

 

 

LED

 

CATH

12

 

Shipped with cover installed.

 

Do not remove.

 

 

Do not install jumpers

 

on these four positions.

 

Drive Front

J6

J6

Jumper Type

 

 

 

(enlarged to

 

 

show detail)

 

 

Pin 1

 

 

End

 

J2

 

 

 

Pin 1

DC Power

 

 

Connector

 

 

 

J1

 

SCSI I/O

J2 Jumper Type

Connector

 

(enlarged to

show detail)

Disable the Delay Motor Start option (default).

Motor start delay equal to the SCSI ID multiplied by 12 seconds. For example, if the SCSI ID = 2, the drive starts in 24 seconds.

Motor Start option

Disable motor start (default). The drive starts according to the Delay Motor Start option.

Enable motor start. The drive waits for the Start Unit command from the host before starting the spindle motor.

Write Protect option

Write protect = Off (enables writing – default).

Write protect = On (disables writing).

Parity Check option

Enable parity check of SCSI bus (default).

Disable parity check.

Figure 8. Additional jumper options

Image 37
Contents ST19171N/W/WD/WC/DC Contents Electrostatic discharge protection PrefaceImportant safety information and precautions Page Wichtige Sicherheitshinweise Barracuda 9 Installation Guide, Rev. B Barracuda 9 Installation Guide, Rev. B Page Electromagnetic susceptibility Regulatory agency complianceElectromagnetic compliance for the European Union Online services Seagate technical support servicesSeagate CompuServe forum SeaFAX FAX servicesSeagate technical support Direct-support servicesManufacturer’s representatives Customer service centersGeneral description Characteristics ST19171 OD DC Barracuda 9 Installation Guide, Rev. B Page General information Drive modelsDrive termination Scsi ID jumpersScsi bus termination Circuits and data path widths Terminator powerProviding adequate cooling Barracuda 9 Installation Guide, Rev. B Kühlung des Systems Suggested air flow Abbildung 3. Empfohlener Luftstromverlauf Installation des Laufwerkes und Anschluß der Kabel Mounting the drive and connecting cablesBarracuda 9 Installation Guide, Rev. B DC power connector Abbildung 4. Gleichstromanschluß Hinweis Quick reference desktop system notes Formatting the drive Drives Setting the Scsi ID jumpersTerminating the drive Terminating the driveSetting terminator power jumpers Several other jumper options are available as illustrated Other applicable jumper optionsWD drives Using the J1 auxiliary jumper block Terminating the drive ST19171W shown ST19171W Other option jumpers are available as illustrated below WC/DC drives Option jumpers are available as illustrated below Applicable jumper optionsPage Page