| Performance | Reference |
Test | Description | level | standard |
|
|
|
|
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV | B | EN |
|
|
|
|
Radiated RF immunity | 80 to 2,000 MHz, 10 V/m, | A | EN |
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
| 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz |
|
|
|
|
|
|
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on external I/O | B | EN |
|
|
|
|
Surge immunity | ± 1 kV differential, ± 2 kV common, AC mains | B | EN |
|
|
|
|
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz | A | EN |
| sine |
|
|
|
|
|
|
Power Frequency | 1 A/m, 50Hz/60Hz, 3 axes | A | EN |
immunity |
|
|
|
|
|
|
|
Voltage dips, interrupts | 30% Reduction for 25 cycles | C | EN |
| >95% Reduction for 250 cycles | C |
|
| >95%, 0.5 cycles | B |
|
|
|
|
|
16 | Momentus 7200 FDE.1 SATA Product Manual, Rev. A |