If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made avail- able for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.

If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.

If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be gen- erated.

The Synchronize Cache command may be used to force the drive to write all cached write data to the medium. Upon completion of a Synchronize Cache command, all data received from previous write commands will have been written to the medium. Table 9 shows the mode default settings for the drive.

5.5.2Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disc immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buf- fer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.

To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch.

The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).

When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disc when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur.

Savvio 10K.4 SAS Product Manual, Rev. E

13

Image 21
Contents ST9600004SS ST9450204SS ST9600204SSST9600104SS ST9450404SSST9450304SSStandard Models Self-Encrypting Drive Models SED Fips 140-2 ModelsRevision history Contents Installation Defect and error managementAbout Fips About self-encrypting drives Interface requirementsPage Savvio 10K.4 SAS Product Manual, Rev. E List of Figures Page Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance for the European Union Electromagnetic complianceAustralian C-Tick Korean KCCEuropean Union Restriction of Hazardous Substances RoHS Reference documentsGeneral description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityFactory-installed options Internal drive characteristics Performance characteristicsSeek performance characteristics Access timeStart/stop time General performance characteristicsPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact Reporting controlTemperature Log Page 0Dh Parameter Code Description Predictive failuresThermal monitor Drive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entriesProduct warranty ShippingProduct repair and return information Physical/electrical specifications PowerChoiceTM power managementPowerChoice modes DC power requirements AC power requirementsPage 450GB standard model DC power requirements 0Gb mode Amps General DC power requirement notes Power sequencingConducted noise immunity Current profiles for 600GB models Current profilesCurrent profiles for 450GB models GB models in 3Gb operation Power dissipation600GB models in 6Gb operation 450GB models in 3Gb operation Temperature a. Operating Environmental limits450GB models in 6Gb operation Relative humidity Effective altitude sea level a. OperatingShock and vibration Shock Recommended mounting Air cleanliness Vibration a. Operating-normalCorrosive environment Acoustics Mounting configuration dimensions Mechanical specificationsAbout Fips PurposeLevel 2 security Admin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseDefect and error management Drive internal defects/errorsDrive error recovery procedures SAS system errors Background Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Setting and determining the current Type LevelProtection Information PI Levels of PIIdentifying a Protection Information drive Drive orientation InstallationAir flow CoolingGrounding Drive mountingInterface requirements SAS featuresDual port support Supported commands Scsi commands supportedSupported commands Supported commands Supported commands Mode Sense data Inquiry dataSavvio inquiry data Page Mode Pages Mode Sense data for 600GB drivesMode Sense values for 450GB drives Miscellaneous operating features and conditions Miscellaneous featuresMiscellaneous status SAS physical interface Datum B Section C C Section a a Connector requirements Physical characteristicsElectrical description Pin descriptionsPower Signal characteristicsSAS transmitters and receivers Ready LED OutLED drive signal SAS-2 Specification complianceDifferential signals General interface characteristicsNumerics IndexKCC Msid Mtbf See also cooling Page Savvio 10K.4 SAS Product Manual, Rev. E Page Seagate Technology LLC