7.5.4.1Shock
a.
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding:
•40 Gs at a maximum duration of 11ms (half sinewave)
•25 Gs at a maximum duration of 2ms (half sinewave)
Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.
b.
The limits of
The drive subjected to nonrepetitive shock not exceeding the three values below, shall not exhibit device damage or performance degradation.
•80 Gs at a maximum duration of 11ms (half sinewave)
•400 Gs at a maximum duration of 2ms (half sinewave)
•300 Gs at a maximum duration of 0.5ms (half sinewave)
Shock may be applied in the X, Y, or Z axis.
Savvio 10K.4 SAS Product Manual, Rev. E | 33 |