5.0Reliability specifications

The following reliability specifications assume correct host and drive operational interface, including all inter- face timings, power supply voltages, environmental requirements and drive mounting constraints.

Seek error rate:

Read Error Rates1

Recovered Data

Unrecovered Data

Miscorrected Data

Interface error rate:

Mean Time Between Failures (MTBF) Annualized Failure Rate (AFR): Preventive maintenance:

Less than 10 errors in 108 seeks

Less than 10 sectors in 1012 bits transferred (OEM default settings) Less than 1 sector in 1016 bits transferred

Less than 1 sector in 1021 bits transferred

Less than 1 error in 1012 bits transferred with minimum receive eye. Less than 1 error in 1014 bits transferred with typical receive eye. See Section 9.6.4, "FC Differential input." on page 66 2,000,000 hours

0.44%

None required

1.Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.

5.1Error rates

The error rates stated in this manual assume the following:

The drive is operated in accordance with this manual using DC power as defined in Section 6.3

Errors caused by host system failures are excluded from error rate computations.

Assume random data.

Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write retries and full retry time.

5.1.1Recoverable Errors

Recovereable errors are those detected and corrected by the drive, and do not require user intervention.

Recoverable Data errors will use Error Correction when needed.

Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a read, and using write bits transferred for recoverable errors occurring during a write.

5.1.2Unrecoverable Errors

Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 1016 bits trans- ferred. Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block.

Savvio 10K.4 FC Product Manual, Rev. A

13

Image 19
Contents ST9600204FC ST9450404FC Savvio 10K.4 FCRev. a 03/26/10 Initial release Revision historyContents Installation Seagate Technology support services Savvio 10K.4 FC Product Manual, Rev. a Scope Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-19 Reference documentsGeneral description Media description Standard featuresReliability PerformanceFormatted capacities User-installed accessories Factory-installed optionsProgrammable drive capacity Seek performance Performance characteristicsInternal drive characteristics Access timePrefetch/multi-segmented cache control Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact Thermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingTemperature Log Page 0Dh Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bAbort Product warrantyPowerChoiceTM power management Physical/electrical specificationsPowerChoice modes AC power requirements DC power requirements for ST9600204FC model 2Gb 4Gb Amps DC power requirementsDC power requirements for ST9450404FC model 2Gb 4Gb Amps Power sequencing General DC power requirement notesConducted noise immunity Current profiles Savvio 10K.4 FC Product Manual, Rev. a ST9600204FC Power dissipationST9450404FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Package size Packaged/product weight Drop heightCorrosive environment Air cleanlinessVibration a. Operating-normal AcousticsChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsDrive internal defects/errors Defect and error managementDrive error recovery procedures 77.87 Background Media Scan FC-AL system errorsMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Savvio 10K.4 FC Product Manual, Rev. a Temperature page 0Dh Inquiry data Mode Sense dataSavvio 10K.4 FC inquiry data Bytes Data hex Page Mode Data Header 34 65 f8 70 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Warranty Support Direct.seagate.com Spp.seagate.com Seagate Technology support servicesWeb Presales Support Technical Support Warranty ServiceData Recovery Services Authorized Service Centers Data Recovery Services Call Center Toll-free Direct dialSavvio 10K.4 FC Product Manual, Rev. a Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC