9.3.1Inquiry data
Table 16 lists the Inquiry command data that the drive should return to the initiator per the format given in the Fibre Channel Interface Manual.
Table 16: | Savvio 10K.4 FC inquiry data |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bytes | Data (hex) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00 | 00 |
| xx** | 12 | 8B | 00 | PP | 02 | 53 | 45 | 41 | 47 | 41 | 54 | 45 | 20 | Vendor ID | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[53 | 54 |
| 39 | 36 | 30 | 30 | 32 | 30 | 34 | 46 | 43]1 | 20 | 20 | 20 | 20 | 20 | Product ID | |
R# | R# |
| R# | R# | S# | S# | S# | S# | S# | S# | S# | S# | 00 | 00 | 00 | 00 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00 | 00 |
| 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00 | 00 |
| 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00 | 00 |
| 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00 | 43 |
| 6F | 70 | 79 | 72 | 69 | 67 | 68 | 74 | 20 | 28 | 63 | 29 | 20 | 32* | *Copyright | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30* | 30* |
| 39* | 20 | 53 | 65 | 61 | 67 | 61 | 74 | 65 | 20 | 41 | 6C | 6C | 20 | notice | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
72 | 69 |
| 67 | 68 | 74 | 73 | 20 | 72 | 65 | 73 | 65 | 72 | 76 | 65 | 64 | 20 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Copyright year (changes with actual year).
**SCSI Revision support. Refer to the appropiate SPC release documentation for definitions.
PP50 = Inquiry data for an Inquiry command received on Port A. 70 = Inquiry data for an Inquiry command received on Port B.
R# | Four ASCII digits representing the last four digits of the product firmware release number. | |||||||||||
S# | Eight ASCII digits representing the eight digits of the product serial number. |
| ||||||||||
[ ] | Bytes 16 through 26 reflect model of drive. The table above shows the hex values for model ST9600204FC. | |||||||||||
| Bytes 16 through 26 values for other models are shown below: |
|
|
| ||||||||
| ST9450404FC | 53 | 54 | 39 | 34 | 35 | 30 | 34 | 30 | 34 | 46 | 43 |
| ST9600204FC | 53 | 54 | 39 | 36 | 30 | 30 | 32 | 30 | 34 | 46 | 43 |
9.3.2Mode Sense data
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The drive maintains four sets of mode parameters:
1.Default values
Default values are
2.Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that are allowed to be changed can be changed by this method. Parameters in the saved values list that are not changeable by the Mode Select command get their values from default values storage.
When power is applied to the drive, it takes saved values from the media and stores them as current val- ues in volatile memory. It is not possible to change the current values (or the saved values) with a Mode Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a “Check Condition” status.
On drives requiring unique saved values, the required unique saved values are stored into the saved val- ues storage location on the media prior to shipping the drive. Some drives may have unique firmware with unique default values also.
Savvio 10K.4 FC Product Manual, Rev. A | 53 |