2.0Standards, compliance and reference documents

The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achieve opti- mum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regu- lation. In particular, the drive must be securely mounted in order to guarantee the specified performance char- acteristics. Mounting by bottom holes must meet the requirements of Section 8.4.

2.1Standards

The Savvio 10K.4 FC family complies with Seagate standards as noted in the appropriate sections of this man- ual and the Seagate Fibre Channel Interface Manual, part number 100293070.

The drives are recognized in accordance with UL 60950-1 and CSA 60950-1 as tested by UL and EN60950-1 as tested by TUV.

The security features of Savvio 10K.4 FC SED models are based on the “TCG Storage Architecture Core Specification” and the “TCG Storage Workgroup Security Subsystem Classs: Enterprise_A” specification with additional vendor-unique features as noted in this product manual.

2.1.1Electromagnetic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. As such the drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communica- tions.

The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. As such, the drive is capable of meeting the Class B limits of the FCC Rules and Regula- tions of the Canadian Department of Communications when properly packaged. However, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host con- troller.

2.1.1.1Electromagnetic susceptibility

As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Table 2, DC power requirements.

2

Savvio 10K.4 FC Product Manual, Rev. A

Image 8
Contents Savvio 10K.4 FC ST9600204FC ST9450404FCRevision history Rev. a 03/26/10 Initial releaseContents Installation Seagate Technology support services Savvio 10K.4 FC Product Manual, Rev. a Scope Standards, compliance and reference documents StandardsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-19General description Standard features Media descriptionFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsUser-installed accessories Performance characteristics Internal drive characteristicsAccess time Seek performanceFormat command execution time minutes General performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T Reporting control Determining ratePredictive failures Thermal monitorState of the drive prior to testing Temperature Log Page 0DhDrive Self Test DST DST failure definitionInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortPowerChoice modes Physical/electrical specificationsPowerChoiceTM power management AC power requirements DC power requirements DC power requirements for ST9600204FC model 2Gb 4Gb AmpsDC power requirements for ST9450404FC model 2Gb 4Gb Amps Conducted noise immunity General DC power requirement notesPower sequencing Current profiles Savvio 10K.4 FC Product Manual, Rev. a Power dissipation ST9600204FCST9450404FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Package size Packaged/product weight Drop height Recommended mountingAir cleanliness Vibration a. Operating-normalAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Mounting configuration dimensionsDrive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Deferred Auto-Reallocation Idle Read After WriteInstallation Drive ID/option selectionDrive orientation CoolingDrive mounting Air flowGrounding FC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Savvio 10K.4 FC Product Manual, Rev. a Temperature page 0Dh Savvio 10K.4 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header 34 65 f8 70 00 00 02 Miscellaneous operating features and conditions Supported Feature or conditionPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesAlpa SEL ID Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Web Seagate Technology support servicesWarranty Support Direct.seagate.com Spp.seagate.com Technical Support Warranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Presales SupportSavvio 10K.4 FC Product Manual, Rev. a Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC