Seagate ST9500432SS, ST9500430SS, ST9500431SS Start/stop time, General performance characteristics

Page 19

5.2.2Format command execution time for 512-byte sectors (minutes) ST9500430SS, ST9500431SS & ST9500432SS

Maximum (with verify)

216

Maximum (without verify)

108

Note. There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity.

5.2.3General performance characteristics

Minimum sector interleave

1 to 1

Data buffer to/from disc media (one 512-byte logical block)*

75 to 142 MBytes/sec

Sustained transfer rate

95 to 100 Mbytes/sec

SAS Interface maximum instantaneous transfer rate

600 Mbytes/sec* per port

 

(dual port = 1200 Mbytes/sec*)

Logical block sizes

 

512 (default), 520 or 528.

 

Read/write consecutive sectors on a track

Yes

Flaw reallocation performance impact (for flaws reallocated at format time using the

Negligible

spare sectors per sparing zone reallocation scheme.)

 

Average rotational latency

4.16 msec

*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.

5.3Start/stop time

The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied.

If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.

The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec- onds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch on the drive.

Constellation SAS Product Manual, Rev. E

11

Image 19
Contents SED Fips 140-2 Model ST9500430SSST9500431SSST9500432SS Standard Model Self-Encrypting Drive ModelRevision history Contents Interface requirements Defect and error managementInstallation About Fips About self-encrypting drivesPower Constellation SAS Product Manual, Rev. E GB model current profiles List of FiguresConstellation SAS Product Manual, Rev. E Seagate Online Support and Services Seagate Technology support servicesScope Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityKorean KCC Electromagnetic complianceElectromagnetic compliance for the European Union Australian C-TickEuropean Union Restriction of Hazardous Substances RoHS Reference documentsGeneral description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesFactory-installed options Access time Performance characteristicsInternal drive characteristics Seek performance characteristicsStart/stop time General performance characteristicsCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsReporting control 4 S.M.A.R.TControlling S.M.A.R.T Performance impactPredictive failures Temperature Log Page 0Dh Parameter Code DescriptionThermal monitor Implementation State of the drive prior to testingDrive Self Test DST DST failure definitionLog page entries Short and extended testsShort test Function Code 001b Extended test Function Code 010bShipping Product warrantyProduct repair and return information PowerChoiceTM power management Physical/electrical specificationsPowerChoice modes DC power requirements AC power requirementsPage Power sequencing General DC power requirement notesConducted noise immunity GB model current profiles Current profilesST9500430SS, ST9500431SS and ST9500432SS in 3 Gbit operation Power dissipationST9500430SS, ST9500431SS and ST9500432SS in 6 Gbit operation Environmental limits Temperature a. OperatingShock Relative humidityEffective altitude sea level a. Operating Shock and vibrationPage Recommended mounting Vibration a. Operating-normal Air cleanlinessCorrosive environment Acoustics Mounting configuration dimensions Mechanical specificationsPurpose About FipsLevel 2 security Data encryption Controlled accessAdmin SP About self-encrypting drivesData bands Default passwordRandom number generator RNG Drive lockingCryptographic erase Authenticated firmware downloadPower requirements Supported commandsDrive internal defects/errors Defect and error managementDrive error recovery procedures SAS system errors Media Pre-Scan Background Media ScanDeferred Auto-Reallocation Idle Read After Write Drive orientation InstallationAir flow CoolingGrounding Drive mountingInterface requirements SAS featuresDual port support Supported commands Scsi commands supportedSupported commands Supported commands Supported commands Inquiry data Mode Sense dataConstellation inquiry data Page Mode Data Header Miscellaneous features Miscellaneous operating features and conditionsMiscellaneous status SAS physical interface Datum B Section C C Section a a Pin descriptions Physical characteristicsConnector requirements Electrical descriptionReady LED Out Signal characteristicsPower SAS transmitters and receiversGeneral interface characteristics SAS-2 Specification ComplianceLED drive signal Differential signalsConstellation SAS Product Manual, Rev. E Numerics IndexKCC Msid Mtbf See also cooling Page Constellation SAS Product Manual, Rev. E Page Seagate Technology LLC