Word | Description | Value |
|
|
|
59 | Number of sectors transferred during a Read Multiple or Write Multiple | xxxxH |
| command |
|
|
|
|
Total number of | ST94011A = 78,140,160 | |
| (see Section 2.2 for related information) | ST92011A = 39,070,080 |
| ST94811A = 78,140,160 | |
|
| |
|
| ST92811A = 39,070,080 |
|
|
|
62 | Retired | 0000H |
|
|
|
63 | Multiword DMA active and modes supported (see note following this table) | xx07H |
|
|
|
64 | Advanced PIO modes supported (modes 3 and 4 supported) | 0003H |
|
|
|
65 | Minimum multiword DMA transfer cycle time per word (120 nsec) | 0078H |
|
|
|
66 | Recommended multiword DMA transfer cycle time per word (120 nsec) | 0078H |
|
|
|
67 | Minimum PIO cycle time without IORDY flow control (240 nsec) | 00F0H |
|
|
|
68 | Minimum PIO cycle time with IORDY flow control (120 nsec) | 0078H |
|
|
|
0000H | ||
|
|
|
75 | Queue depth | 0000H |
|
|
|
0000H | ||
|
|
|
80 | Major version number | 007EH |
|
|
|
81 | Minor version number | 0000H |
|
|
|
82 | Command sets supported | 346BH |
|
|
|
83 | Command sets supported | 7D09H |
|
|
|
84 | Command sets support extension | 4003H |
|
|
|
85 | Command sets enabled | 34xxH |
|
|
|
86 | Command sets enabled | 3xxxH |
|
|
|
87 | Command sets enable extension | 4003H |
|
|
|
88 | Ultra DMA support and current mode | xx3FH |
| (see note following this table) |
|
|
|
|
89 | Security erase time | 0000H |
90 | Enhanced security erase time | 0000H |
91 | Advanced power management value | 0040H |
92 | Master password revision code | FFFEH |
93 | Hardware reset value (see description following this table) | xxxxH |
94 | Auto acoustic management setting | xxxxH |
0000H | ||
128 | Security status | 0001H |
129– | xxxxH | |
159 |
|
|
|
|
|
160– | 0000H | |
254 |
|
|
|
|
|
255 | Integrity word | xxA5H |
|
|
|
24 | Momentus 5400.1 Product Manual, Rev. F |