Table 1: | Specifications |
|
|
|
|
|
|
|
|
|
|
| |
Drive specification | ST94011A |
| ST94811A | ST92011A | ST92811A | |
|
|
|
|
| ||
22 (typical); 26 (max) |
|
| ||||
|
|
|
|
| ||
Seek power (typical) | 2.4 watts |
|
|
| ||
|
|
|
|
| ||
Read/write power (typical) | 2.4 watts |
|
|
| ||
|
|
|
|
| ||
Idle mode (typical) | 1.2 watts |
|
|
| ||
|
|
|
|
| ||
Standby mode |
| 0.36 watts (typical)** |
|
| ||
|
|
|
|
| ||
Sleep mode |
| 0.36 watts (typical)** |
|
| ||
|
|
|
|
| ||
Voltage tolerance (including noise) | 5V ± 5% |
|
|
| ||
|
|
|
| |||
Ambient temperature | 5° to 55°C (operating) |
|
| |||
|
|
|
| |||
|
|
|
|
| ||
Temperature gradient (°C per hour max) | 20°C (operating) |
|
|
| ||
|
| 30°C (nonoperating) |
|
| ||
|
|
|
| |||
Relative humidity (noncondensing) | 5% to 90% (operating) |
|
| |||
|
| 5% to 95% (nonoperating) |
|
| ||
|
|
|
|
| ||
Relative humidity gradient | 30% per hour max |
|
|
| ||
|
|
|
|
| ||
Wet bulb temperature (°C max) | 33°C (operating) |
|
|
| ||
|
| 40°C (nonoperating) |
|
| ||
|
|
| ||||
Altitude, operating |
| |||||
|
|
| ||||
Altitude, nonoperating (below mean sea level, max) |
| |||||
|
|
|
|
|
| |
Shock, operating (Gs max at 2 msec) | 225 |
|
|
|
| |
|
|
|
|
|
| |
Shock, nonoperating (Gs max at 2 msec) | 800 |
|
|
|
| |
|
|
|
|
|
| |
Shock, nonoperating (Gs max at 1 msec) | 800 |
|
|
|
| |
|
|
|
|
|
| |
Shock, nonoperating (Gs max at 0.5 msec) | 400 |
|
|
|
| |
|
|
|
| |||
Vibration, operating (max displacement may apply below | 1.0 Gs (0 to peak, |
|
| |||
10 hz) |
|
|
|
|
|
|
|
|
|
| |||
Vibration, nonoperating (max displacement may apply | 5.0 Gs (0 to peak, |
|
| |||
below 22 hz) |
|
|
|
|
|
|
|
|
|
|
|
| |
Drive acoustics, sound power (bels) |
|
|
|
|
| |
Idle* |
| 2.3 (typical) |
|
|
| |
|
| 2.5 (max) |
|
|
| |
Quiet seek |
| 2.5 (typical) |
|
|
| |
|
| 2.7 (max) |
|
|
| |
Performance seek | 3.0 (typical) |
|
|
| ||
|
| 3.2 (max) |
|
|
| |
|
|
|
| |||
Nonrecoverable read errors | 1 per 1014 bits read |
|
| |||
Mean time between failures | 330,000 at 25°C |
|
|
| ||
|
| Max case temperature: 60°C |
|
| ||
|
|
|
|
|
| |
Load/Unload (U/UL) cycles |
|
|
|
|
| |
25°C, 50% relative humidity | 300,000 |
| ||||
|
| 20,000 hard power on/off cycles |
|
| ||
32°C, 80% relative humidity | 100,000 |
| ||||
5°C, 80% relative humidity | 20,000 hard power on/off cycles |
|
| |||
5°C, 10% relative humidity |
|
|
|
|
| |
55°C, 16% relative humidity |
|
|
|
|
| |
|
|
|
|
|
| |
Service life |
| 5 Years |
|
|
| |
|
|
|
|
|
| |
Warranty |
| 1 Year |
|
|
| |
|
|
|
|
|
|
|
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
**Typical notebooks will pull power to the drive when entering S3 and S4; while in the S3 and S4 states, drive sleep and drive standby modes will not contribute to battery power consumption.
4 | Momentus 5400.1 Product Manual, Rev. F |