Seagate ST39173N/W/WD/LW/WC/LC, ST34573N/W/WD/LW/WC/LC manual Dimensions of the drive

Page 22

20

Barracuda 9LP Installation Guide, Rev. E

[5]See “Conducted noise immunity” in the Barracuda 9LP Prod- uct Manual. The specified voltage tolerance is inclusive of ripple, noise, and transient response.

[6]Operating condition is defined as random seek read opera- tions with a block count of 64.

General Notes from Tables 2a, 2b, and 2c.

1.Minimum current loading for each supply voltage is not less than 4% of the maximum operating current shown.

2.Use separate ground returns for +5V and +12V supplies.

3.Where power is provided to multiple drives from a common supply, carefully consider individual drive power require- ments. Where multiple units are powered on simultaneously, be sure the peak starting current is available to each device.

Table 3.

Dimensions of the drive

 

 

 

 

inches

mm

 

 

 

 

 

 

Height

1.00

25.4

 

 

 

Width

4.00

101.6

 

 

 

Depth

5.75

146.05

 

 

 

Weight

1.3 pounds (0.589 kilograms)

 

 

 

Image 22
Contents ST39173N/W/WD/LW/WC/LC ST34573N/W/WD/LW/WC/LC Contents Preface Electrostatic discharge protectionImportant safety information and precautions Page Wichtige Sicherheitshinweise Page Barracuda 9LP Installation Guide, Rev. E Electromagnetic susceptibility Regulatory agency complianceElectromagnetic compliance Electromagnetic compliance for the European Union Australian C-TickSeagate Technology support services Presales Support Customer Service CSO European Support Services Africa/Middle East Support Services 14Barracuda 9LP Installation Guide, Rev. E General description Drive characteristics RPMDC power requirements Amps, single-ended ST39173N/W/WC DCXDCX DC power requirements Amps, multimode ST39173LW/LC ST34573LW/LCDimensions of the drive Drive models General informationScsi ID jumpers Drive termination Terminator power Circuits and data path widthsCable characteristics for single-ended I/O circuits Cable characteristics for differential I/O circuits Fifty pin I/O connection to drive Multiple drive connection to host adapter Multiple-drive connection to host adapter Barracuda 9LP Installation Guide, Rev. E Providing adequate cooling Kühlung des Systems Suggested air flow Abbildung 4. Empfohlener Luftstromverlauf Mounting the drive and connecting cables Installation des Laufwerkes und Anschluß der KabelPage DC power connector Abbildung 5. Gleichstromanschluß Hinweis Barracuda 9LP Installation Guide, Rev. E Mounting configuration dimensions Formatting the drive Quick reference desktop system notes Setting the Scsi ID jumpers DrivesTerminating the drive Terminating the driveSetting terminator power jumpers Other applicable jumper options Additional jumper optionsSetting the Scsi ID on model W/WD drives WD/LW drivesHost Alternate WD drives Terminating the drive W model shownWD model drives Additional jumper options for W, WD, and LW drives LW drives Additional jumper option for LW drivesWC/LC drives WC drives Applicable jumper optionsLC drives Jumper options for LC drivesAdditional jumper options for LC drives Page