As shown in Figure 5.5 and Figure 5.6, the Serial Parameters Menus allow you to define the following parameters:

Baud Rate: Baud Rate for the IPS COM Port. (Default = 9600 bps.)

Note: When this setting is changed, the new baud rate will not be applied until the user exits and then re-enters command mode.

Data: The Data Bits setting for the IPS COM Port. (Default = 8 Bits.)

Parity: The parity setting for the IPS COM Port. (Default = None.)

Stop: The Stop Bits setting for the IPS COM Port. (Default = 1 Bit.)

Port Mode: Sets up the serial COM / RS232 Port for use with either a local PC or an external modem. Note that when the Port Mode is set to "Modem" the modem initialization string will be sent every 15 minutes. (Default = Console.)

Modem Initialization String: Defines a command string (up to

32 characters long) which can be sent out the serial COM Port to initialize an external modem. If the Port Mode is set to "Console", the modem initialization string will not be sent. For more information on initialization commands, please refer to the user’s guide for your modem. (Default = ATE0M0Q1&C1&D2S0=1)

Notes:

The Modem Initialization String cannot begin with a forward slash (/) or backslash (\) character.

The Modem Initialization String cannot include non printable characters or quotation marks.

5-10

Image 28
Contents IPS-800CE-D16 IPS-1600CE-D16 User’s GuidePage Installation Instructions EMC, Safety, and R&TTE Directive Compliance Table of Contents List of Figures Introduction IPS-800CE-D16 and IPS-1600CE-D16 Units Typographic ConventionsUnit Description IPS-800CE-D16 Back Panel 8-Plug UnitIPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Apply Power to the IPS Hardware InstallationQuick Start Communicating with the IPS Connect your PC to the IPSText Interface Text Interface Type /X and press Enter Power Supply Connection InstallationInstalling the Cable Keepers Connection to Switched Outlets Serial COM / RS232 Port ConnectionConnecting a Local PC Connecting the Network CableConnecting an External Modem IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Configuration System Mode and User ModeAccessing the Web Browser Interface Plug Status Screen Web Browser Interface IPS-800CE-D16 ShownAccessing the Text Interface $ telnet 192.168.168.168 Enter Configuration Menus General Parameters Menus General Parameters Menu Web Browser InterfaceGeneral Parameters Menu Text Interface IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Serial Parameters Menu Serial ParametersIPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Plug Parameters Menus Plug #1 ParametersPlug Passwords and Co-Location Features Reboot Cycles Network Parameters Menu Web Browser Interface Network Parameters Menus IP Security Feature Confi guration Telnet Parameters Menus 12 Telnet Parameters Menu Web Browser InterfaceWeb Server Parameters Menus 14 Web Server Parameters Menu Web Browser InterfaceSave Configuration Parameters Operation via the Web Browser Interface OperationPlug Status Screen Web Browser Interface Plug Status Menu Web Browser Interface IPS-800CE-D16 Shown Operation via the Text Interface Plug Status Screen Text InterfaceSwitching and Reboot Commands Text Interface IPS Help Screen Text InterfaceBoot 1 or /BO Atmswtch Logging Out of Command Mode Applying Commands to Several Plugs Text InterfaceAutomated Mode Manual Operation Saving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading the IPS Firmware IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Serial COM / RS232 Port Interface Interface DescriptionApx-1 Specifications Apx-2Customer Service Apx-3Trademark and Copyright Information Apx-4Index Index-1Index-2 IPS-800/1600-D20 Series User’s GuidePage Sterling Irvine California 949 586-9950 Toll Free