Western Telematic IPS-800CE-D16, IPS-1600CE-D16 manual Automated Mode

Page 45

Operation

6.4. The Automated Mode

The Automated Mode allows the IPS to execute switching and reboot commands, without displaying menus or generating response messages. Automated Mode is designed to allow the IPS to be controlled by a device which can generate commands to control power switching functions without human intervention.

When Automated Mode is enabled, the /ON, /OFF, /BOOT, /D and /X commands are executed without a "Sure?" confirmation prompt and without command response messages; the only reply to these commands is the "IPS>" prompt, which is displayed when the command is complete.

Note that although Automated Mode can be enabled using either the Web Browser Interface or Text Interface, Automated Mode is designed primarily for users who wish to send ASCII commands to the IPS without operator intervention, and therefore does not specifically apply to the Web Browser Interface. When Automated Mode is enabled, the Web Browser Interface can still be used to invoke On / Off / Boot commands.

Notes:

When Automated Mode is enabled, all IPS password security functions are disabled, and users are able to access System Level command functions (including the configuration menus) and control plugs without entering a password.

If you need to enable the Automated Mode, but want to restrict network access to IPS configuration menus, it is recommended to enable and configure the IP Security Function as described in Section 5.3.4.1.

To enable/disable Automated Mode, access the General Parameters menu (see Section 5.3.1,) then set the "Automated Mode" option to "On". When Automated Mode is enabled, IPS functions will change as follows:

1.All Password Security Suppressed: When a user attempts to access command mode, the password prompt will not be displayed at either the COM / RS232 Port or the Network Port. Unless specifically restricted by the IP Security Function, all users will be allowed to access both switching and configuration functions, and all commands will be immediately accepted without the requirement to enter a password.

2.Status Screen Suppressed: The status screens will not be automatically displayed after commands are successfully executed. Note however, that the /S command can still be invoked to display the status screen as needed.

6-7

Image 45
Contents User’s Guide IPS-800CE-D16 IPS-1600CE-D16Page Installation Instructions EMC, Safety, and R&TTE Directive Compliance Table of Contents List of Figures Introduction Typographic Conventions IPS-800CE-D16 and IPS-1600CE-D16 UnitsIPS-800CE-D16 Back Panel 8-Plug Unit Unit DescriptionIPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Hardware Installation Apply Power to the IPSQuick Start Connect your PC to the IPS Communicating with the IPSText Interface Text Interface Type /X and press Enter Installation Power Supply ConnectionInstalling the Cable Keepers Serial COM / RS232 Port Connection Connection to Switched OutletsConnecting the Network Cable Connecting a Local PCConnecting an External Modem IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide System Mode and User Mode ConfigurationPlug Status Screen Web Browser Interface IPS-800CE-D16 Shown Accessing the Web Browser InterfaceAccessing the Text Interface $ telnet 192.168.168.168 Enter Configuration Menus General Parameters Menu Web Browser Interface General Parameters MenusGeneral Parameters Menu Text Interface IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Serial Parameters Serial Parameters MenuIPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Plug #1 Parameters Plug Parameters MenusPlug Passwords and Co-Location Features Reboot Cycles Network Parameters Menu Web Browser Interface Network Parameters Menus IP Security Feature Confi guration 12 Telnet Parameters Menu Web Browser Interface Telnet Parameters Menus14 Web Server Parameters Menu Web Browser Interface Web Server Parameters MenusSave Configuration Parameters Operation Operation via the Web Browser InterfacePlug Status Screen Web Browser Interface Plug Status Menu Web Browser Interface IPS-800CE-D16 Shown Plug Status Screen Text Interface Operation via the Text InterfaceIPS Help Screen Text Interface Switching and Reboot Commands Text InterfaceBoot 1 or /BO Atmswtch Applying Commands to Several Plugs Text Interface Logging Out of Command ModeAutomated Mode Manual Operation Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading the IPS Firmware IPS-800CE-D16 & IPS-1600CE-D16 User’s Guide Interface Description Serial COM / RS232 Port InterfaceApx-1 Apx-2 SpecificationsApx-3 Customer ServiceApx-4 Trademark and Copyright InformationIndex-1 IndexIPS-800/1600-D20 Series User’s Guide Index-2Page Sterling Irvine California 949 586-9950 Toll Free