6.2. Common AT Commands

This section lists some of the most commonly used AT commands for the APS-8/16M’s internal modem. For a complete listing of all available AT Commands and S-Registers, please refer to the "MT5634 Modem AT Command Set" document at http://www.wti.com/guides/guidarch.htm.

Notes:

Type commands in either upper or lower case. Do not use a combination of upper and lower case characters.

Use the Backspace key to delete errors.

All commands begin with the AT prefix, and are invoked by pressing [Enter]. The only exceptions are A/ (Repeat Previous Command) and +++ (Exit to on-line command mode).

The maximum command length is 40 characters. This does not include the AT Prefix, Carriage Returns, or spaces.

Default settings are marked with an asterisk (*).

Command Function/Options

Zn Reset Modem. Resets modem parameters to default values. Z0 Reset modem to profile saved by the last

&W command.

Z1 Same as Z0

Ds Dials telephone number s. Where s may be up to 40 characters long and may include the numbers 0-9, *, #, B, C, and D characters and the L, P, T, V, W, S, comma (,), semicolon (;), !, @, ^ and $ dial string modifiers.

Dial String Modifiers:

LRedial last number. (Must be placed immediately after ATD.)

PPulse-dial following numbers in command line.

T Tone Dial following numbers in command line.

W Wait for a new dial tone before continuing to dial

(X2, X4, X5, X6 or X7 must be selected.)

, (Comma) Pause during dialing for time set in Register S8.

; Return to command mode after dialing. (Place at end of dial string.)

! Hook Flash. Causes modem to go on-hook for one half second, then off hook again.

@ Wait for quiet answer. Causes modem to wait for a ringback, then 5 seconds of silence, before processing the next part of the command. If silence is not detected, the modem returns a NO ANSWER code.

6-2

Image 38
Contents User’s Guide Models CoveredPage Grounding Secure RackingInput Supply Disconnect Power Shock Hazard Do Not EnterTable of Contents List of Figures Introduction APS-8M and APS-16M Units Configuration BackupModem Communication Typographic ConventionsUnit Description Front Panel Power Switch Back PanelConnect your Equipment to the Serial Ports Hardware InstallationGetting Started Access Command Mode Communicating with the APS-8/16MPort Status Screen Model APS-8M Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide AC Powered Units Hardware InstallationConnecting Power to the APS Unit DC Powered UnitsConnecting Devices to the APS Serial Ports Connect a Telco Line to the Modem PortConfiguration Access to the APS-8/16M Command ModeSystem SetUp Ports Password FunctionsSystem Parameters Menu System Parameters Menu /F Password Directory Edit Password DirectoryAdding Passwords Editing and Deleting Passwords Deleting the Entire Password Directory Dial Back FunctionSystem Parameters Menu Add Name/Password MenuDial Back Example Port Configuration Configuration ConventionsPort Modes 3. RS232 Port Configuration Menus RTS/CTSConfiguration Port Parameters Menu Modem Mode Port 3 Shown Configuration APS-8M / APS-16M Asynchronous Port Switches User’s Guide Invalid Access Lockout Feature Copying Parameters to All Ports Copy Port ParametersSave User Selected Parameters APS-8M / APS-16M Asynchronous Port Switches User’s Guide Internal Modem Communicating with the Internal ModemDial String Modifiers Common AT CommandsCommand Function/Options Data Terminal Ready DTR Control Command Function/Options Status Screens Port Status Screen /SPort Diagnostics Screen /SD Port Diagnostics Screen Model APS-8M Defaults Shown Password Directory Screen /V Port Parameters Screens /WPassword Directory Screen Sample Values Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide Port Connection and Disconnection Any-to-Any ModeOperation Disconnecting Ports EnterThree Characters Uses the format EnterLLLEnter, where Defining Hunt Groups Server EnterHunt Group Example Passive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersOperation APS-8M / APS-16M Asynchronous Port Switches User’s Guide Saving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading APS-8/16M Firmware 10-110-2 11-1 Command Reference GuideCommand Conventions Command Response 11-2Command Summary 11-3Terse Command SetFormat Response 11-411-5 Format /C x x EnterFormat /CP Enter Format /E/Y x x Enter Format /D/Y x x Enter2 Enter or /D/Y 3 Enter 11-6Format /I/Y Enter Format /F EnterFormat /H Enter 11-7Format /SD Enter Format /P x EnterFormat /S Enter 11-8Format /UL Enter Format /U EnterFormat /UF Enter Format /V Enter11-10 Format /W x EnterFormat /X Enter RS232 Port Interface Apx-1RS232 Port Interface SpecificationsPower Stop Bits 1 orCustomer Service Apx-3Apx-4 Trademark and Copyright InformationTrademarks Used in this Manual Regulatory Statements Apx-5EMC, Safety, and R&TTE Directive Compliance Apx-6Index Index-1Index-2 Index-3 IndexIndex-4 Page Sterling Irvine California 949 586-9950 Toll Free