Western Telematic APS-16M, APS-8M manual Command Summary, 11-3

Page 63

Command Reference Guide

11.3. Command Summary

 

 

Command Availability

Function

Command Syntax

Supervisor

Non-Supervisor

Enter Command Mode

[Enter]

X

X

Exit Command Mode

/X [Enter]

X

X

Help Menu

/H [Enter]

X

X

Display Site ID

/J [Enter]

X

X

Display Port Status

/S [Enter]

X

X

Display Port Diagnostics

/SD [Enter]

X

X

Display Port Parameters

/W [n] [Enter]

X

X

(Who)

 

 

 

Display Password

/V [Enter]

X

 

Directory

 

 

 

Set System Parameters

/F [Enter]

X

 

Set RS232 Port

/P <x> [Enter]

X

 

Parameters

 

 

 

Copy RS232 Port

/CP [Enter]

X

 

Parameters

 

 

 

Connect

/C <x> [x] [Enter]

X

X

Resident Disconnect

^X

X

X

Third Party Disconnect

/D[/Y] <x> [x] [Enter]

X

 

 

/D[/Y] * [Enter]

 

 

Unlock All Ports (Invalid

/UL [Enter]

X

 

Access)

 

 

 

Erase Buffer

/E[/Y] <x> [x] [Enter]

X

 

 

/E[/Y] * [Enter]

 

 

Default & Test

/I[/Y] [Enter]

X

 

Save Parameters

/U [Enter]

X

 

Upgrade Firmware

/UF [Enter]

X

 

Supervisor Mode displays parameters for all ports; Non-Supervisor Mode only displays parameters for ports allowed by Port Password.

Ports and passwords that do not permit access to Supervisor Mode can only view parameters for the ports that are specifically allowed by the password entered at log in.

Ports and passwords that do not permit access to Supervisor Mode are not allowed to perform a Third Party Connect.

Resident Disconnect: Disconnects your resident port from another port. Note that the Resident Disconnect Sequence can be redefined via the Port Configuration Menus.

Third Party Disconnect: Disconnects two or more nonresident ports. Must be issued from a third port where Supervisor Mode is active.

11-3

Image 63
Contents Models Covered User’s GuidePage Secure Racking Input SupplyGrounding Shock Hazard Do Not Enter Disconnect PowerTable of Contents List of Figures Introduction Typographic Conventions Configuration BackupModem Communication APS-8M and APS-16M UnitsFront Panel Unit DescriptionBack Panel  Power SwitchHardware Installation Getting StartedConnect your Equipment to the Serial Ports Communicating with the APS-8/16M Access Command ModePort Status Screen Model APS-8M Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide DC Powered Units Hardware InstallationConnecting Power to the APS Unit AC Powered UnitsConnect a Telco Line to the Modem Port Connecting Devices to the APS Serial PortsAccess to the APS-8/16M Command Mode ConfigurationPassword Functions System SetUp PortsSystem Parameters Menu System Parameters Menu /F Edit Password Directory Password DirectoryAdding Passwords Editing and Deleting Passwords Dial Back Function Deleting the Entire Password DirectoryAdd Name/Password Menu Dial Back ExampleSystem Parameters Menu Configuration Conventions Port ConfigurationPort Modes RTS/CTS 3. RS232 Port Configuration MenusConfiguration Port Parameters Menu Modem Mode Port 3 Shown Configuration APS-8M / APS-16M Asynchronous Port Switches User’s Guide Invalid Access Lockout Feature Copy Port Parameters Copying Parameters to All PortsSave User Selected Parameters APS-8M / APS-16M Asynchronous Port Switches User’s Guide Communicating with the Internal Modem Internal ModemCommon AT Commands Command Function/OptionsDial String Modifiers Data Terminal Ready DTR Control Command Function/Options Port Status Screen /S Status ScreensPort Diagnostics Screen /SD Port Diagnostics Screen Model APS-8M Defaults Shown Port Parameters Screens /W Password Directory Screen /VPassword Directory Screen Sample Values Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide Any-to-Any Mode OperationPort Connection and Disconnection Enter Disconnecting PortsThree Characters Uses the format EnterLLLEnter, where Server Enter Defining Hunt GroupsHunt Group Example Buffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeOperation APS-8M / APS-16M Asynchronous Port Switches User’s Guide Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters 10-1 Upgrading APS-8/16M Firmware10-2 Command Reference Guide Command Conventions11-1 11-2 Command Response11-3 Command Summary11-4 Command SetFormat Response TerseFormat /C x x Enter Format /CP Enter11-5 11-6 Format /D/Y x x Enter2 Enter or /D/Y 3 Enter Format /E/Y x x Enter11-7 Format /F EnterFormat /H Enter Format /I/Y Enter11-8 Format /P x EnterFormat /S Enter Format /SD EnterFormat /V Enter Format /U EnterFormat /UF Enter Format /UL EnterFormat /W x Enter Format /X Enter11-10 Apx-1 RS232 Port InterfaceStop Bits 1 or SpecificationsPower RS232 Port InterfaceApx-3 Customer ServiceTrademark and Copyright Information Trademarks Used in this ManualApx-4 Apx-5 Regulatory StatementsApx-6 EMC, Safety, and R&TTE Directive ComplianceIndex-1 IndexIndex-2 Index Index-3Index-4 Page Sterling Irvine California 949 586-9950 Toll Free