Western Telematic APS-16M, APS-8M Operation, Any-to-Any Mode, Port Connection and Disconnection

Page 47

8. Operation

8.1. Any-to-Any Mode

Any-to-Any Mode Ports can be connected to other Any-to-Any, Passive, Buffer, or Modem Mode Ports by accessing command mode and issuing the /C Command. All ports can be configured for the Any-to-Any Mode.

8.1.1.Port Connection and Disconnection

The APS-8/16M provides communication between devices without the requirement that both devices use the same communication parameters. This allows you to connect devices that use dissimilar baud rates, parity, handshake, and etc. The APS-8/16M converts data rates and other parameters, eliminating the need to select common parameters for all connected devices.

8.1.1.1. Connecting Ports

Two different types of connections can be made between APS-8/16M ports; Resident Connections and Third Party Connections.

Resident Connections: Your resident port issues a /C command to connect to a second port. For example, Port 4 issues the /C command to connect to Port 5.

Third Party Connections: (Supervisor Mode Only) Your resident port issues a /C command to create a connection between two other ports. For example, Port 1 is your resident port, and Port 1 issues a command to connect Port 2 to Port 3.

Notes:

Third Party Connections can only be initiated by ports and passwords that permit access to Supervisor Mode.

If a port has accessed command mode using a password that does not permit Supervisor Mode, then that port will only be able to connect to the ports that are specifically allowed by the password definition.

8-1

Image 47
Contents Models Covered User’s GuidePage Grounding Secure RackingInput Supply Shock Hazard Do Not Enter Disconnect PowerTable of Contents List of Figures Introduction Typographic Conventions Configuration BackupModem Communication APS-8M and APS-16M UnitsFront Panel Unit DescriptionBack Panel  Power SwitchConnect your Equipment to the Serial Ports Hardware InstallationGetting Started Communicating with the APS-8/16M Access Command ModePort Status Screen Model APS-8M Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide DC Powered Units Hardware InstallationConnecting Power to the APS Unit AC Powered UnitsConnect a Telco Line to the Modem Port Connecting Devices to the APS Serial PortsAccess to the APS-8/16M Command Mode ConfigurationPassword Functions System SetUp PortsSystem Parameters Menu System Parameters Menu /F Edit Password Directory Password DirectoryAdding Passwords Editing and Deleting Passwords Dial Back Function Deleting the Entire Password DirectorySystem Parameters Menu Add Name/Password MenuDial Back Example Configuration Conventions Port ConfigurationPort Modes RTS/CTS 3. RS232 Port Configuration MenusConfiguration Port Parameters Menu Modem Mode Port 3 Shown Configuration APS-8M / APS-16M Asynchronous Port Switches User’s Guide Invalid Access Lockout Feature Copy Port Parameters Copying Parameters to All PortsSave User Selected Parameters APS-8M / APS-16M Asynchronous Port Switches User’s Guide Communicating with the Internal Modem Internal ModemDial String Modifiers Common AT CommandsCommand Function/Options Data Terminal Ready DTR Control Command Function/Options Port Status Screen /S Status ScreensPort Diagnostics Screen /SD Port Diagnostics Screen Model APS-8M Defaults Shown Port Parameters Screens /W Password Directory Screen /VPassword Directory Screen Sample Values Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide Port Connection and Disconnection Any-to-Any ModeOperation Enter Disconnecting PortsThree Characters Uses the format EnterLLLEnter, where Server Enter Defining Hunt GroupsHunt Group Example Buffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeOperation APS-8M / APS-16M Asynchronous Port Switches User’s Guide Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters 10-1 Upgrading APS-8/16M Firmware10-2 11-1 Command Reference GuideCommand Conventions 11-2 Command Response11-3 Command Summary11-4 Command SetFormat Response Terse11-5 Format /C x x EnterFormat /CP Enter 11-6 Format /D/Y x x Enter2 Enter or /D/Y 3 Enter Format /E/Y x x Enter11-7 Format /F EnterFormat /H Enter Format /I/Y Enter11-8 Format /P x EnterFormat /S Enter Format /SD EnterFormat /V Enter Format /U EnterFormat /UF Enter Format /UL Enter11-10 Format /W x EnterFormat /X Enter Apx-1 RS232 Port InterfaceStop Bits 1 or SpecificationsPower RS232 Port InterfaceApx-3 Customer ServiceApx-4 Trademark and Copyright InformationTrademarks Used in this Manual Apx-5 Regulatory StatementsApx-6 EMC, Safety, and R&TTE Directive ComplianceIndex-1 IndexIndex-2 Index Index-3Index-4 Page Sterling Irvine California 949 586-9950 Toll Free