/W Display Port Parameters (Who)

Displays detailed configuration information for an individual port. Ports with User Level command capability cannot display parameters for other ports. If you have logged into command mode using a port and password that permit Supervisor Mode, the /W command can display information for any APS-8/16M port. However, if you have logged into command mode using a port or password that do not permit Supervisor Mode, the /W command will only display information for your resident port. For more information, please refer to Section 7.3.

Availability: Supervisor Mode / Non-Supervisor Mode

Format: /W [x] [Enter]

Where x is the Port number or name. If the "x" argument is omitted, parameters for your resident port will be displayed.

Response: Displays port parameters.

Example: To display parameters for a port named "SERVER", access the Command Mode from a port with Supervisor Level command capability, and type /W SERVER [Enter].

/X Exit Command Mode

Exits command mode. When issued at the Net Port, also ends the telnet session. Note that exiting from command mode will not terminate port connections.

Any-to-Any Mode: Exits command mode.

Modem Mode: Disconnects and resets modem, hang-up message is sent, hardware line to modem drops for 500 ms, and modem reset string is sent.

Availability: Supervisor Mode / Non-Supervisor Mode

Format: /X [Enter]

Response: Disconnected

11-10

Image 70
Contents User’s Guide Models CoveredPage Input Supply Secure RackingGrounding Disconnect Power Shock Hazard Do Not EnterTable of Contents List of Figures Introduction APS-8M and APS-16M Units Configuration BackupModem Communication Typographic ConventionsUnit Description Front Panel Power Switch Back PanelGetting Started Hardware InstallationConnect your Equipment to the Serial Ports Access Command Mode Communicating with the APS-8/16MPort Status Screen Model APS-8M Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide AC Powered Units Hardware InstallationConnecting Power to the APS Unit DC Powered UnitsConnecting Devices to the APS Serial Ports Connect a Telco Line to the Modem PortConfiguration Access to the APS-8/16M Command ModeSystem SetUp Ports Password FunctionsSystem Parameters Menu System Parameters Menu /F Password Directory Edit Password DirectoryAdding Passwords Editing and Deleting Passwords Deleting the Entire Password Directory Dial Back FunctionDial Back Example Add Name/Password MenuSystem Parameters Menu Port Configuration Configuration ConventionsPort Modes 3. RS232 Port Configuration Menus RTS/CTSConfiguration Port Parameters Menu Modem Mode Port 3 Shown Configuration APS-8M / APS-16M Asynchronous Port Switches User’s Guide Invalid Access Lockout Feature Copying Parameters to All Ports Copy Port ParametersSave User Selected Parameters APS-8M / APS-16M Asynchronous Port Switches User’s Guide Internal Modem Communicating with the Internal ModemCommand Function/Options Common AT CommandsDial String Modifiers Data Terminal Ready DTR Control Command Function/Options Status Screens Port Status Screen /SPort Diagnostics Screen /SD Port Diagnostics Screen Model APS-8M Defaults Shown Password Directory Screen /V Port Parameters Screens /WPassword Directory Screen Sample Values Shown APS-8M / APS-16M Asynchronous Port Switches User’s Guide Operation Any-to-Any ModePort Connection and Disconnection Disconnecting Ports EnterThree Characters Uses the format EnterLLLEnter, where Defining Hunt Groups Server EnterHunt Group Example Passive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersOperation APS-8M / APS-16M Asynchronous Port Switches User’s Guide Saving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading APS-8/16M Firmware 10-110-2 Command Conventions Command Reference Guide11-1 Command Response 11-2Command Summary 11-3Terse Command SetFormat Response 11-4Format /CP Enter Format /C x x Enter11-5 Format /E/Y x x Enter Format /D/Y x x Enter2 Enter or /D/Y 3 Enter 11-6Format /I/Y Enter Format /F EnterFormat /H Enter 11-7Format /SD Enter Format /P x EnterFormat /S Enter 11-8Format /UL Enter Format /U EnterFormat /UF Enter Format /V EnterFormat /X Enter Format /W x Enter11-10 RS232 Port Interface Apx-1RS232 Port Interface SpecificationsPower Stop Bits 1 orCustomer Service Apx-3Trademarks Used in this Manual Trademark and Copyright InformationApx-4 Regulatory Statements Apx-5EMC, Safety, and R&TTE Directive Compliance Apx-6Index Index-1Index-2 Index-3 IndexIndex-4 Page Sterling Irvine California 949 586-9950 Toll Free