(master and slave screens, continued)
| FORMAT: | [option] |
|
| OPTIONS: | Disabled | DIsables the feature. |
|
| Standard | Standard is 1 sector per |
|
|
| block. |
|
| 2 sectors | Number of sectors trans- |
|
| 4 sectors | ferred per block. |
|
| 8 sectors |
|
|
| 16 sectors |
|
|
|
| |
| NOTES: | All options are dependent on the drive. | |
|
|
|
|
| FORMAT: | [option] |
|
| OPTIONS: | Disabled / Enabled | Enabling LBA causes logi- |
LBA Mode Control |
|
| cal block addressing to be |
|
| used in place of Cylin- | |
|
|
| ders, Heads, and Sectors. |
|
|
| |
| NOTES: | All options are dependent on the drive. | |
|
|
|
|
| FORMAT: | [option] |
|
| OPTIONS: | Disabled / Enabled | Enables |
|
|
| cation between CPU and |
|
| IDE card. Requires PCI or | |
|
|
| local bus. |
|
|
| |
| NOTES: | All options are dependent on the drive. | |
|
|
|
|
| FORMAT: | [option] |
|
| OPTIONS: | Standard | Selects the method for |
|
| Fast PIO 1 | transferring data between |
|
| Fast PIO 2 | the HDD and system |
Transfer Mode |
| Fast PIO 3 | memory. |
|
| Fast PIO 4 |
|
|
|
| |
| NOTES: | The Setup menu only lists those options sup- | |
|
| ported by the drive and platform. | |
|
|
|
|
| FORMAT: | [option] |
|
| OPTIONS: | Disabled / Enabled | |
|
|
| Reporting Technology, |
SMART Monitoring |
|
| which monitors condition |
|
|
| of the HDD and reports |
|
|
| when a catastrophic IDE |
|
|
| failure is about to happen. |
|
|
|
|
Tiger MP S2460