6.Reboot the system and enter the FastBuild Utility main menu.
7.Select 5 to rebuild the array.
FastBuild ™ Utility 1.xx ©
[Rebuild Array Menu]
Array No | RAID Mode | Total Drv | Capacity (MB) | Status | |||
Array 1 | Mirror | 2 |
| 16126 |
| Critical | |
Array 2 |
|
|
| ||||
Array 3 |
|
|
| ||||
Array 4 |
|
|
| ||||
|
|
|
| [Keys Available] |
|
| |
|
| [− ] Up | [↓] Down | [ESC] Exit | [Enter] Select |
8.Highlight the array with “Critical” status and press Enter.
FastBuild ™ Utility 1.xx ©
[Rebuild Array Menu]
Array No | RAID Mode | Total Drv | Status |
Array 2 | Mirror | 2 | Critical |
Stripe Block: Not Available |
|
| |
| [Select Drive for Rebuild] | ||
Channel:ID | Drive Model | Capacity (MB) | |
1: Slave | QUANTUMCR8.4A | 8063 |
|
|
| [Keys Available] |
|
| [− ] Up [↓] Down | [ESC] Exit | [Enter] Select |
9.Highlight the replacement drive under [Select Drive for Rebuild] .
10.Press Enter. All existing data on the replacement drive will be written over with mirrored information from the array drive. A progress bar will appear on the screen.
11.Reboot the system when the process is completed.
52