Omega 3200ST, 3400ST manual Connections For The 9 Pin D Sub Connector

Page 11

d)Connections For The 9 Pin D Sub Connector

Using a suitable mating connector the pins of the integrated connector should be wired as follows:

Connecting To The Integrated 9 Pin Connector

Pin Out of Integrated

Connector

PIN 3 should be connected to the Positive of the power source.

PIN 4 should be connected to the Negative ( Ground ) of the power source.

PIN 2 provides the signal output and should be connected to the positive terminal of the display, data acquisition system or voltmeter.

PIN 8 is the signal negative (ground) and should be connected to the negative (Ground) terminal of the display, data acquisition system or voltmeter.

Pin 6 is the input signal and should be connected to the positive terminal of the voltage source. The (0-5VDC) voltage control signal should be supplied from a low impedance source.

Pin 7 is the input signal negative (ground) and should be connected to the negative (Ground) terminal of the voltage source.

Pins 1, 5, and 9 are not used.

Caution: Avoid high voltage static discharges to the input signal connection. Do not short the input/output signal pins or allow them to contact the power connections at any time. DAMAGE WILL RESULT!

M-4271/0707, pg. 11 of 26

Image 11
Contents Page Page General Product Overview and Principle of Operation IntroductionUnpacking General Considerations Installation4271/0707, pg Tubing Connections Mounting the Flow ControllerElectrical Connections Overview Connecting The 6 Pin Mini Din Connector Connecting The 6 Pin Mini Din Connector & FMA 3000C Cable Connections For The 9 Pin D Sub Connector Connections For The 15 D Sub Connector Using a 0-5VDC Input / Output Power Adapter Package Flow Readings OperationWarm Up Verification of ZeroQ1 / Q2 = K1 / K2 Changing The Flow Rate Set-Point FMA3400/3400ST Series Only Power Save ModeChanging the Calibration Gas FMA 3400/3400ST Series Only Zero AdjustmentsRecalibration Returning Units for Repair or Recalibration Maintenance and Product CareGeneral Series FMA FMA 3200ST FMA 3400ST SpecificationsDimensions FMA 3400/3400ST Series 1/4 Stainless Fittings Shown Gas Chemical Gas K FactorsSymptom Possible Cause Method of Correction Troubleshooting GuideSymptom Possible Cause Method of Correction 4271/0707, pg 4271/0707, pg