Omron Healthcare VARISPEEDF7 specifications User Parameter, EN-18

Page 19

User Parameter

Param-

 

 

eter

Name

Description

Num-

 

 

ber

 

 

Initialize Data

 

 

Language

0:English

 

selection for

 

2:German

 

Digital Opera-

A1-00

3:French

tor dis-

4:Italian

 

 

play(JVOP-

5:Spanish

 

6:Portuguese

 

160-OY only)

 

 

 

 

 

 

 

0:Monitoring only (Monitoring drive

 

 

mode and setting A1-01 and A1-04.)

 

 

1:Used to select user parameters (Only

 

Parameter

parameters set in A2-01 to A2-32 can

A1-01

be read and set.)

access level

2:Advanced

 

 

 

(Parameters can be read and set in

 

 

both, quick programming mode (Q)

 

 

and advanced programming mode

 

 

(A).

 

 

 

 

Control method

0:V/f control

A1-02

1:V/f control with PG

selection

2:Open loop vector control

 

 

 

3:Closed loop vector control

 

 

 

 

 

0: No initializing

 

 

1110:Initializes using the user

 

 

parameters

A1-03

Initialize

2220:Initializes using a two-wire

sequence. (Initializes to the factory

 

 

 

 

setting.)

 

 

3330: Initializes using a three-wire

 

 

sequence.

 

 

 

Sequence / Reference Source

 

 

Sets the frequency reference input

 

Reference

method.

b1-01

source selec-

0:Digital Operator

 

tion

1:Control circuit terminal (analog input)

 

2:Serial communication (RS422 / 485)

 

 

 

 

3:Option Card

 

 

 

 

RUN com-

Sets the run command input method.

 

0:Digital Operator

b1-02

mand source

1:Control circuit terminal (digital inputs)

 

selection

2:Serial communication (RS422 / 485)

 

 

3:Option Card

 

 

 

 

 

Selects the stopping method when the

 

 

Run signal is removed

 

Stopping

0:Deceleration to stop

b1-03

method selec-

1:Coast to stop

 

tion

2:DC injection to stop

 

3:Coast to stop with timer (New Run

 

 

 

 

commands are disregarded while

 

 

coasting.)

 

 

 

 

 

0:Reverse enabled

 

Prohibition of

1:Reverse disabled

b1-04

reverse opera-

2:Output Phase Rotation (both rota-

tional directions are enabled)

 

tion

 

3:Output Phase Rotation with Reverse

 

 

disabled.

 

 

 

Acceleration / Deceleration Settings

C1-

Acceleration/

Sets the time to accelerate/decelerate

Deceleration

from 0 Hz to the maximum output fre-

††

 

times

quency.

 

 

 

S-Curve Settings

 

C2-

S-curve char-

Sets the S-curve characteristic at accel-

acteristic time

††

eration start and end.

 

at acceleration

 

Param-

 

 

eter

Name

Description

Num-

 

 

ber

 

 

 

 

 

Motor Slip Compensation (not available in V/f with PG)

 

 

Used to improve speed accuracy

C3-01

Slip compensa-

• Increase if output frequency is too low

tion gain

• Decrease if output frequency is too

 

 

high.

 

 

 

 

Slip compensa-

Sets the slip compensation delay time

 

tion delay time

• Increase if output frequency is not

C3-02

stable

 

(only available

• Decrease setting when slip compen-

 

in V/f and OLV)

 

sation responsiveness is low.

 

 

 

 

 

Speed Control (ASR) (only available in V/f with PG and CLV)

C5-01

ASR propor-

Sets the proportional gain of the speed

 

tional gain 1

loop (ASR)

 

 

 

 

 

C5-02

ASR integral

Sets the integral time of the speed loop

 

time 1

(ASR)

 

 

C5-03

ASR propor-

P,I

 

 

 

 

P = C5-01

 

tional gain 2

 

 

I = C5-02

 

 

 

 

P = C5-03

 

 

 

 

 

ASR integral

 

 

I = C5-04

C5-04

 

 

 

time 2

0

E1-04

Motor

 

 

 

 

speed (Hz)

 

 

 

 

 

C5-06

ASR delay time

Sets the ASR filter time constant.

(only CLV)

 

 

 

 

ASR switching

Sets the frequency for switching

C5-07

frequency

between ASR gain 1, 2 and ASR integral

 

(only CLV)

time 1, 2

 

 

 

 

 

 

 

 

ASR integral

Sets the limit for the integral part of the

C5-08

limit

ASR controller.

 

 

 

(only CLV)

 

 

 

 

 

 

 

 

 

 

 

Carrier

Frequency

 

 

 

 

Heavy/Normal

0:Heavy Duty

 

 

C6-01

1:Normal Duty 1

 

 

 

duty selection

2:Normal Duty 2

 

 

 

 

 

 

 

 

 

 

 

Selects the carrier frequency (factory

 

 

setting depends on Inverter

capacity)

 

Carrier fre-

0: Low noise, low carrier

 

 

1: 2.0 kHz

 

 

C6-02

quency selec-

2: 5.0 kHz

 

 

 

tion

3: 8.0 kHz

 

 

 

4: 10.0 kHz

 

 

 

 

 

 

 

 

5: 12.5 kHz

 

 

 

 

6: 15.0 kHz

 

 

 

 

F: Programmable pattern

 

 

 

 

 

 

Speed

Settings

 

 

 

d1-01

Multi speed

 

 

 

to

references 1 to

 

 

 

d1-16

16

Sets the multi-step speed references.

 

 

 

 

 

d1-17

Jog frequency

 

 

 

reference

 

 

 

 

 

 

 

 

 

 

 

Torque

Control (only

available in CLV)

 

d5-01

Torque control

0:Speed control

 

 

selection

1:Torque control

 

 

 

 

 

 

 

 

 

Speed/torque

Sets the delay from inputting a “speed/

 

torque control change” signal (by digital

d5-06

control switch

input) until the control is acutally

 

over timer

 

changed

 

 

 

 

 

 

 

 

 

 

 

V/f Pattern Settings

 

 

 

E1-01

Input voltage

This setting is used as a reference value

setting

for protection functions.

 

 

 

 

 

 

 

 

EN-18

Image 19
Contents VARISPEED F7 F7Z Quick Start Guide Table of Contents EN-2 EN-3 ‹ Safety Precautions and Instructions„ Notes EN-4‹ EMC Compatibility „ Electrical Connection„ Laying Cables EN-5Earthing the cable shield with metal clips „ Unpacking the Inverter ‹ Mechanical Installation„ Checking the Installation Site EN-6„ Installation of Inverters and EMC filters „ Installation OrientationEN-7 Wiring Diagram ‹ Electrical Connection „Wiring the InverterEN-8 „Main Circuit Terminals EN-9„Control Circuit Terminals During run no Closed during Run Function EN-10Flywheel Diode Connection EN-11 „ Sinking/Sourcing Mode NPN/PNP SelectionSinking / Sourcing Mode and Input Signals External Power Source Sinking Mode NPNEN-12 ‹ Wiring Main Circuit InputsInput Fuse Selection EN-13 „Wiring the Output Side of the Main Circuit„Control Circuit Wiring Precautions Ground Wiring‹ Digital Operator Display optional EN-14„Digital Operator Keys EN-15 ‹ Start Up Procedure„ Setting the Autotuning Mode ‹ Before Power Up‹ Display after Power Up ‹ AutotuningEN-17 „Other Alarms and Faults During AutotuningEN-18 User ParameterVbase EN-19Fmax VmaxLimit only OLV and CLV EN-20EN-21 ‹ General Faults and AlarmsOL2 EN-22OH1 OL1EN-23 ‹ Operator Programming ErrorsEN-24 ‹ Autotuning FaultsOPE08

VARISPEEDF7 specifications

The Omron Healthcare VARISPEEDF7 is an innovative and advanced medical device designed to provide effective therapy for various health conditions. This cutting-edge device is part of Omron’s commitment to enhancing healthcare solutions and promoting patient well-being through technology. The VARISPEEDF7 is particularly notable for its versatility and effectiveness in various therapeutic applications.

One of the main features of the VARISPEEDF7 is its adjustable speed settings. This allows healthcare professionals to customize the therapy according to the specific needs of each patient. The ability to vary speed enhances treatment effectiveness, as different conditions may require different intensities. The device is designed to accommodate a wide range of therapeutic needs, making it a valuable tool in clinical and home healthcare settings alike.

The VARISPEEDF7 integrates several advanced technologies, including its proprietary motor control system. This system provides smooth and consistent operation, minimizing disruptions during therapy sessions. The technology ensures precise speed control, enabling healthcare providers to maintain optimal conditions for therapy.

In addition to its speed control, the VARISPEEDF7 is equipped with a user-friendly interface. The display provides clear information about settings and progress, making it easy for both healthcare professionals and patients to monitor treatment sessions. The intuitive design reduces the learning curve and enhances the overall user experience.

Another significant characteristic of the VARISPEEDF7 is its portability. The compact design allows for easy transport and storage, making it ideal for patients who require therapy at home or on the go. This feature is particularly beneficial for individuals with mobility issues or those who enjoy an active lifestyle.

Durability is also a hallmark of the VARISPEEDF7. It is built with high-quality materials that ensure longevity and reliability, even with frequent use. This commitment to durability highlights Omron’s dedication to providing healthcare solutions that practitioners and patients can trust.

In summary, the Omron Healthcare VARISPEEDF7 represents a significant advancement in therapeutic technology. With its adjustable speed settings, advanced motor control system, user-friendly interface, portability, and durability, the VARISPEEDF7 is designed to meet the diverse needs of patients and healthcare providers. It stands out as a versatile solution that enhances patient care and promotes effective treatment outcomes. As healthcare continues to evolve, the VARISPEEDF7 exemplifies how innovative technologies can make a substantial impact on health and well-being.