Omega Vehicle Security OM-550 manual Statistics

Page 21

2.4.2 STATISTICS

When the STOP key pressed after a data run, the Statistics are then printed. This printout shows the date, time, number of samples taken (N), and the minimum, average, and maximum values (by channel) of the data presently stored in the cache:

Figure 2-15

If "******" appears on the tape, as shown in Figure 2-15, the value stored in cache memory is not printable.

If the selected Log Interval was shorter than the time required to log (or log and print) the data, the Statistics will include a warning (refer to section 4.6 LOG INTERVAL for more information).

LOG INTERVAL WARNING

Figure 2-16

If no samples were taken, no data has been written to the cache. In this case, N=0 and there will be no statistics to print.

OM-550

u16u

Image 21
Contents Table of Contents Date Time ∙ The OM-550 Datalogger may be referred to as Logger IntroductionProduct Usage Warnings Operator Safety InformationFor protection of the OM-550 itself, observe the following Unpacking Features OM-550 FeaturesOM-550 features Activity LED & Horn Keypad ∙ ON-OFF ∙ RUN ∙ Stop ∙ PROG/EXIT∙ OK Channel Connectors ∙ Optional ConnectorsApplication To remove the Viewing Window Printer WindowThermal Paper Battery CoverDC Jack Serial Data PortTilt Stand Gain AdjustPower Supplies Voltage Transducer Inputs Inputs Probes Probe SETType Thermocouple InputsData Cache Programmed FeaturesStatistics POWER-SAVE Mode LOW Battery OperationBattery Check Battery Installation Power ConnectionConnecting the DC Power Cable Connecting the AC Power AdapterPaper Installation PIN Adapter Data Port Connection∙ Programming outline 1. Select Channel ProgrammingProgramming Keys Position Print FormattingVoltage Channels Temperature ChannelsMath PSEUDO-CHANNEL LOG Interval This Interval Overrun can be avoided in two waysNot Printing Operation AT Full Cache Recording Time Rejection Frequency Temperature UnitsTo return to Normal mode Calibration ModeTadjust Matching Transducers to the OM-550 Voltage Input ScalingMatching a Voltage Transducer R1 = 2 R2 = V-2Matching a Current Transducer = 2.0000 VDC = R1R1 = 2 Data Scaling mX + b calculation Matching and Scaling a Voltage Transducer VDC Example Matching and Scaling a Current TransducerU38u Unit Labels Programmed Information OperationLog Interval Time Temperature Units Enter a Tadjust value, or press OK to finish programming U44u Appendix a Calibration ∙ Manual Reset Manual Reset programs the OM-550 as follows∙ Performing a Manual Reset Setup ∙ Calibration Procedure∙ Thermocouple Adjustment Procedure ∙ Voltage Adjustment ProcedureTo return to normal operation ∙ Exiting CAL ModeAppendix B Specifications Voltage Measurement InputsAccuracy Paper Life PrinterDigital Interface RS-232 ConversionBattery Life POWER/CURRENT RequirementsPhysical Dimensions ConnectorsOM-550 DOS Software Table of Contents Introduction How to Use This ManualFonts Used in this Manual Printer CPU, RAM, Hardware∙ Hard Drive Installation Software InstallationTo start the program Starting the ProgramMaster Menu Reading Data from the OM-550 To load a LOG file Load Existing LOG FilesModify Software Configuration U6u To list data List Data on MonitorSave Text File Print Data on PrinterTo print data To save data as textTo edit a plot label Edit Plot LabelsHOT Plot Status BAR To Magnify a portion of the Data Graph Magnify ToolMagnify MAP Magnified Area Axis Labels To select a channel to graph Channel DataTo link plot lines Channels 4 & 5 After Linking Data Graph ∙ Data Plots ∙ X-Data Cursors∙ X-Cursor Data Table To activate the Help menu Help MenuList Existing LOG Files on Printer To list log filesTo quit Appendix a KEY Functions