PRINTER

 

TYPE:

24-Column Thermal

PAPER ROLL CAPACITY:

82 ft ±1.6 ft

LINE HEIGHT:

0.150 inches per printed line

LINES PER ROLL:

6,560 ±128

PAPER LIFE

 

(Printing 5 channels every 10-min.)

Approximately 217 hours or 9 days

DIGITAL INTERFACE (RS-232)

 

COMMUNICATION FORMAT:

9600 baud, No parity, 8 data bits, 1 stop

 

bit

OUTPUT VOLTAGES:

± 9 VDC

A/D CONVERSION

 

RESOLUTION:

±20,000 counts

TECHNIQUE:

Dual slope, selectable 50/60 Hz rejection

CHANNEL CAPACITY

 

NUMBER OF INPUT CHANNELS:

5 Voltage or Thermocouple, 1 Pseudo-

 

math

INTERNAL DATA STORAGE

 

MAXIMUM CAPACITY:

28 Kbytes or 7000 data samples

ENVIRONMENTAL

 

OPERATING AND STORAGE

 

ENVIRONMENT:

Indoor use only

OPERATING TEMPERATURE RANGE:

0°C to 50°C (32ºF to 122ºF)

STORAGE TEMPERATURE RANGE:

-25°C to 75°C (-13ºF to 167ºF)

OPERATING RELATIVE HUMIDITY

 

RANGE:

Maximum 80% R.H. for temperatures up

 

to 31ºC decreasing linearly to Max. 50%

 

R.H. at 40ºC, remaining constant from

 

40ºC to 50ºC.

STORAGE RELATIVE HUMIDITY

 

RANGE:

Max. 95% R.H., non-condensing

MAINS VOLTAGE FLUCTUATION

 

RANGE:

Maximum +10%

This is the maximum fluctuation from the nominal rated input voltage for the AC

Power Adapter.

OM-550

u50u

Image 55
Contents Table of Contents Date Time ∙ The OM-550 Datalogger may be referred to as Logger IntroductionProduct Usage Warnings Operator Safety InformationFor protection of the OM-550 itself, observe the following Unpacking OM-550 Features FeaturesOM-550 features Activity LED & Horn Keypad ∙ ON-OFF ∙ RUN ∙ PROG/EXIT ∙ Stop∙ OK ∙ Optional Connectors Channel ConnectorsApplication To remove the Viewing Window Printer WindowSerial Data Port Battery CoverThermal Paper DC JackTilt Stand Gain AdjustPower Supplies Probe SET InputsVoltage Transducer Inputs ProbesType Thermocouple InputsData Cache Programmed FeaturesStatistics LOW Battery Operation POWER-SAVE ModeBattery Check Battery Installation Power ConnectionConnecting the DC Power Cable Connecting the AC Power AdapterPaper Installation PIN Adapter Data Port Connection∙ Programming outline 1. Select Channel ProgrammingProgramming Keys Position Print FormattingVoltage Channels Temperature ChannelsMath PSEUDO-CHANNEL This Interval Overrun can be avoided in two ways LOG IntervalNot Printing Operation AT Full Cache Recording Time Rejection Frequency Temperature UnitsTo return to Normal mode Calibration ModeTadjust R1 = 2 R2 = V-2 Voltage Input ScalingMatching Transducers to the OM-550 Matching a Voltage Transducer= 2.0000 VDC = R1 Matching a Current TransducerR1 = 2 Data Scaling mX + b calculation Matching and Scaling a Voltage Transducer VDC Example Matching and Scaling a Current TransducerU38u Unit Labels Programmed Information OperationLog Interval Time Temperature Units Enter a Tadjust value, or press OK to finish programming U44u Manual Reset programs the OM-550 as follows Appendix a Calibration ∙ Manual Reset∙ Performing a Manual Reset Setup ∙ Calibration Procedure ∙ Thermocouple Adjustment Procedure ∙ Voltage Adjustment ProcedureTo return to normal operation ∙ Exiting CAL ModeVoltage Measurement Inputs Appendix B SpecificationsAccuracy Conversion PrinterPaper Life Digital Interface RS-232Connectors POWER/CURRENT RequirementsBattery Life Physical DimensionsOM-550 DOS Software Table of Contents Introduction How to Use This ManualFonts Used in this Manual Printer CPU, RAM, Hardware∙ Hard Drive Installation Software InstallationTo start the program Starting the ProgramMaster Menu Reading Data from the OM-550 To load a LOG file Load Existing LOG FilesModify Software Configuration U6u To list data List Data on MonitorTo save data as text Print Data on PrinterSave Text File To print dataTo edit a plot label Edit Plot LabelsHOT Plot Status BAR To Magnify a portion of the Data Graph Magnify ToolMagnify MAP Magnified Area Axis Labels To select a channel to graph Channel DataTo link plot lines Channels 4 & 5 After Linking Data Graph ∙ X-Data Cursors ∙ Data Plots∙ X-Cursor Data Table To activate the Help menu Help MenuTo list log files List Existing LOG Files on PrinterTo quit Appendix a KEY Functions