NETGEAR SC101 manual No Central Storage Device was Found in SmartWizard

Page 16

“No Central Storage Device was Found” in SmartWizard

First, check these items:

At least 1 hard disk must be plugged into the SC101.

Hard disks must be ATA6 or later, and configured as "Cable Select" (CS).

Use a wired connection to configure and modify the SC101.

If there is still a problem, see the table below.

No Central Storage

Action

Device was Found

 

 

Check the Power LED.

The Power LED light should be lit solid green.

 

If it flashes green three times periodically, then something is

 

 

wrong with the response from the DHCP server.

Was the computer or

The SC101 takes more than 2 minutes to reboot.

SC101 recently

If there are many partitions it takes longer.

rebooted?

Wait a few minutes after rebooting before running the SCM to

 

 

locate the disks.

 

Make sure to shut down and restart in the correct order. See

 

 

How To’s or the User Manual.

Are the Microsoft

These freeware utilities can conflict with the SC101.

Security, Socketwatch,

Run the utility again, and remove it (Source to uninstall

or Socketlock utilities

 

utilities).

installed?

 

 

 

 

For more information about problems with these utilities, see

 

reference.

Which firewall is

The SC101 automatically works with the Windows XP

used?

 

Personal Firewall.

 

For other firewalls such as Trend Micro Personal Firewall and

 

 

Norton Firewall, disable the firewall or open UDP port 20001.

Check the LAN

The computer and the SC101 must be connected to the same

connections and subnet

 

LAN and subnet (and not across different routers.

setup.

 

 

 

For example, these two IP addresses are not in the same

 

 

subnet: 255.255.0.0 for the computer and 255.255.255.0 for

 

 

the SC101.

Have the hard disks

Use the UT commands to see a list of partitions that were

been partitioned?

 

created. See Using the UT Command and the SC101

 

Command Line Interface.

 

If there is only the Root partition, this means that you have not

 

 

partitioned your hard disks.

 

 

Create a new partition as described in section "If a partition

 

 

has never been seen on a particular computer" in this article.

Wireless network

To keep a wireless connection between your computers and the

 

SC101, there must regularly be a small amount of data throughput.

 

The SC101 may drop off when operating at the limits of wireless

 

range.

IP address from DHCP

See Using the UT Command and the SC101 Command Line

server.

Interface to confirm that the SC101 got an IP address from the

16

Image 16
Contents Netgear SC101 Revised Troubleshooting Guide Page Troubleshooting Tips Viewing and Accessing DrivesWindows Disk Management Unallocated Partitions Page Page Page Cannot See Partition Old Firmware Problem If a partition has never been seen on a particular computer Click Attach DrivePrerequisites Cannot Create a MirrorIii. Click Attach Drive Check LED Lights URL Link LED Indicators HardwareLink or FritzBox Routers Light Light State What It Means What You Should DoLAN Connection Defragmenting Hard Disk Problems and Drive Errors Hard Disk Problem ActionSCM Installation SolutionTo customize font settings SCM SoftwareError Messages Error Message Meaning and ActionNo Central Storage Device was Found in SmartWizard No Central Storage Action Device was FoundNo Central Storage Device was Found Action Symptoms SmartSync Pro Activation ErrorCause Error Drive attachment failed when Attach Partition Fails SymptomSystem Requirements About the SC101Heat and the SC101 SC101 Performance How does heat affect the Storage Central performance?New Technology File System Ntfs Self-certifying File System SFSSAN and Network Attached Storage NAS SC101 Command Line Interface CLI for Advanced Users Using CLI CommandsType cd c\Program Files\NETGEAR\SC101 Type ut listall, then EnterUnique Name Command utfull getpart Fixing Corrupted Characters00 00 00 00 00 00 00 00 02 00 02 00 00 00 0A 00 00 00 00 00 00 00 00 01 00 01 00 00 00 0ATo disable the Promise drivers and install the SCM Utility Type sc config ftsata2 start= disabledData recovery with SFSExtract.exe Removing an Unusable Drive with ut.exeTo remove an unusable drive from the SC101 Type cd C\Program Files\NETGEAR\SC101 Manager UtilityType SFSExtract Single drive target
Related manuals
Manual 2 pages 44.73 Kb Manual 54 pages 17.75 Kb