Minicom Advanced Systems CMG-DCM manual Appendix B Sensor and digitizer types

Page 97

Operator's guide

Appendix B Sensor and digitizer types

These codes are used in situations where the DCM needs to know the response properties of sensors and digitizers, e.g. when compiling full SEED volumes.

If you are unsure about the code you should use, contact Gü ralp Systems.

Appendix B.1 Sensor response codes

Sensor

CMG-5T or 5TD, DC – 100 Hz response CMG-40T-1 or 6T-1, 1 s – 100 Hz response

CMG-40T-1 or 6T-1, 2 s – 100 Hz response

CMG-40T-1 or 6T-1, 10 s – 100 Hz response

CMG-40, 20 s – 50 Hz response CMG-40, 30 s – 50 Hz response CMG-3T or 3ESP, 30 s – 50 Hz response CMG-40, 60 s – 50 Hz response CMG-3T or 3ESP, 60 s – 50 Hz response CMG-3T or 3ESP, 100 s – 50 Hz response CMG-3T or 3ESP, 120 s – 50 Hz response CMG-3T, 360 s – 50 Hz response

CMG-3TB or 3V / 3ESP borehole, 30 s – 50 Hz response

CMG-3TB or 3V / 3ESP borehole, 100 s – 50 Hz response

CMG-3TB or 3V / 3ESP borehole, 120 s – 50 Hz response

Sensor type code

Units (V/A)

CMG-5_100HZ

A

CMG-40_1HZ_50HZ

V

CMG-40_1S_100HZ

V

CMG-40_2S_100HZ

V

CMG-

V

40_10S_100HZ

 

CMG-40_20S_50HZ

V

CMG-40_30S_50HZ

V

CMG-3_30S_50HZ

V

CMG-40_60S_50HZ

V

CMG-3_60S_50HZ

V

CMG-3_100S_50HZ

V

CMG-3_120S_50HZ

V

CMG-3_360S_50HZ

V

CMG-3B_30S_50HZ

V

CMG-

V

3B_100S_50HZ

 

CMG-

V

3B_120S_50HZ

 

December 2005

97

Image 97
Contents CMG-DCM Table of Contents December Inside the DCM Introduction CMG-DCM Inside the DCM Network services Serial port servicesSee .4, Connecting to a local network for full details Power supply Installing the CMG-DCMOverview Connecting over a serial link Connecting to a single computer192.168.0.x Connecting over EthernetConnecting over USB Using an internal modemConnecting to a local network Gcfgdbset option-namenew-value Connecting to the Internet Wi-FiSetting up the CMG-DCM Connecting digitizers and external hardwareWeb setup Setting up digitizers Using Scream General notes UsageDCM as a data store Gnblocks port-number Page CMG-DCM DCM as a GCF data source Accessing the DCM command line through gcfout Sensor arrays DCM as a network data hub Communicating with digitizers Configuring digitizers Data storage and retrieval Using miniSEED format Real-time data transmission CD1.0 and CD1.1 Troubleshooting DCM installations Cannot connect to the DCMs Scream! server Cannot see the DCMs Web site over Http or HttpsCannot Gcfping the DCMs Scream! server DCM is not receiving any data streams Can Gcfping the DCMs Scream! server, but no data appearsDCM is receiving streams, but they do not contain any data Use the Serial port configuration → port name Web page, or143032 up 34 min, load average 1.24, 1.32 General Configuration optionsDisk CMG-DCM Serial port configuration CMG-DCM Page Ethernet port Network configurationStatic routes DNS setup Incoming mail setup Outgoing mail setup Remote access Administrators PPP Mgetty Scream Data transferAutoDRM Scream! ClientHttp client Http serverCD1.0 CD1.1 CD1.1 subframe configuration DSS Server configuration Seed Page CMG-DCM Data Viewer ActionsStream list Icon barDigitizer Setup General digitizer settings Digitizer output control CMG-DCM Trigger criteria CMG-DCM Tap # Rate Bandwidth Samples/s Auxiliary Mux channels Sensor mass control Partition, and format disk Disk toolsCheck disk filesystem Flush flashCamera Disk filesRecent Log Entries Summary Network configurationData Out Port, Serial Port A, Serial Port B DNS configurationTamper lines Flash StatusDisk Status Software Versions Inside the DCM File systems CMG-DCM Command line tools Configuration Digitizer console access Data flow MonitoringDigitizer status Tamper lines Over the Internet Updating the DCMFrom the hard disk Removing support packagesFirmware Libgconfigdb Appendix A.1 Modular DCM units Appendix a Connector pinoutsPort a and B Data OUT portNetwork connector USB connectorDM/AM module output Appendix A.2 Integrated DCM unitsAppendix B.1 Sensor response codes Appendix B Sensor and digitizer typesDigitizer Appendix B.2 Digitizer type codes