Lightwave Communications LDT-5525 manual Comments, Suggestions, and Problems

Page 13

WA R R A N T Y

Comments, Suggestions, and Problems

To ensure that you get the most out of your ILX Lightwave product, we ask that you direct any product operation or service related questions or comments to ILX Lightwave Customer Support. You may contact us in whatever way is most convenient:

Phone . . . . . . . . . . . . . . . . . . . . . . . . . . . (800) 459-9459 or (406) 586-1244

Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (406) 586-9405

On the web at: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ilx.custhelp.com

Or mail to:

ILX Lightwave Corporation

P. O. Box 6310

Bozeman, Montana, U.S.A 59771

www.ilxlightwave.com

When you contact us, please have the following information:

Model Number:

Serial Number:

End-user Name:

Company:

Phone:

Fax:

Description of what is connected to the ILX Lightwave instrument:

Description of the problem:

If ILX Lightwave determines that a return to the factory is necessary, you are issued a Return Authorization (RA) number. Please mark this number on the outside of the shipping box.

You or your shipping service are responsible for any shipping damage when returning the instrument to ILX Lightwave; ILX recommends you insure the shipment. If the original shipping container is not available, place your instrument

06_07

LDT-5525

xi

Image 13
Contents User’s Guide Page Table of Contents Appendix a Steinhart-Hart Equation Appendix C AD590 and LM335 Sensor Calibration Iv LDT-5525 List of Figures Vi LDT-5525 General Safety Considerations Safety Information and the ManualSafety Marking Symbols Safety SymbolsWarranty Claims for Shipping Damage When you contact us, please have the following information Comments, Suggestions, and ProblemsXii LDT-5525 Product Overview Introduction and SpecificationsDescription Model Number Available Options and AccessoriesOutput1 SpecificationsUser Calibration General Specifications LDT-5525 Operation AC Power ConsiderationsRack Mounting Introduction to the LDT-5525 Front Panel Power-Up SequenceAdjustments Sensor CAL Output Back Panel Controls and Connections Sensor Select SwitchBack Panel TEC Connector TEC ConnectorTEC Grounding Considerations Temperature Mode Operation General Operating ProceduresWarm-Up and Environmental Considerations External Safety Switch Operation Resistance Mode OperationBooster Operation General Operating Procedures LDT-5525 Calibration Overview Maintenance and TroubleshootingEnvironmental Conditions Recommended EquipmentWarm Up Thermistor Calibration Calibration AdjustmentsAD590 Sensor Calibration LM335 Sensor Calibration ITE Current Calibration Symptom Causes and Corrective Actions TroubleshootingTemperature, based on C1 and C2 Table A.1 Comparison of Curve Fitting Equations STEINHART-HART EquationThermistor R/T Curves Computer Program REM Print Using H$ I, TI, RI LDT-5525 Thermistor Range Sensing Current Thermistor SelectionTable B.2 10K Thermistor Temperature Range Selecting and Using Thermistors Temperature ResolutionSelecting the Sensing Current Thermistor Range AD590 Sensor AD590 and LM335 Sensor CalibrationFigure C.1 AD590 Nonlinearity LM335 Sensor0607 Two Point Calibration Method One Point Calibration MethodC1n = U + V * C1 and C2n = V * C2 LDT-5525