TECHNICAL SPECIFICATIONS
Power: | 230 VAC 50 Hz, 7 Watt |
Backup battery: | 1x 9V 6LR61 alkaline block battery |
Backup time: | 1 week typ |
Supply current : | <30 mA |
120 kHz ± 2 kHz / 2.5 | |
Signal sensitivity: | 15 mVpp min, 50 mVpp max at 120 kHz |
Signal / noise ratio | 1,35 : 1 |
1 pulse burst at 0, 60 and 120 degrees. | |
All units Off, All Lights On, On, Off, Dim, Bright, | |
| All Lights Off, Extended Code 1 type 0, Extended |
| Code 1 type 3, Hail Acknowledge, |
| Status Request, RF commands |
All units Off, All Lights On, On, Off, Dim, Bright, | |
| All Lights Off, Extended Code 1 type 3, Hai |
| l Request, |
| RF commands |
Present | |
Input impedance: | > 180 Ohm |
RF Range: | 30 meters (note: the unit should be mounted at |
| a height of 1metre for best performance and |
| located away from any sources of RF interference |
| such as computers, monitors, etc). |
RF Power: | 10 mW (maximum) |
RF receiver frequency: | 433,92 MHz |
RF transmitter frequency: | 433,92 MHz |
Ambient temperature: | |
| (storage) |
Weight: | 20 grams |
Dimensions: | 66.7 (w) x 113.5 (L) x 45.3 (H) |
Specifications may be modified without prior notice.
ENGLISH
Environmental Information for Customers in the European Union
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help
prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
CM15Pro™ + ActiveHome Pro™ | 11 |