MaxTech 800, 28 user manual Section Four S Registers

Page 12

\Kn

Set break control (n= 0-5). Default is 5

\N0

Normal data-link only

\N1

Direct data-link only

\N2

MNP data link only

\N3

MNP or Normal data link

\N4

V.42 data link only

\N5

V.42 or MNP data link only

\N6

V.42/MNP/Normal data link

\O

Initiate reliable link during a normal link

\Q0

Turn off flow control

\Q1

XON/XOFF software flow control

\Q2

CTS signal unidirectional hardware flow control

\Q3

RTS/CTS signal bi-directional hardware flow

 

control

\Q4

Unidirectional XON/XOFF software flow control

 

(modem to host)

\Tn

Inactivity timer (n = 0 to 90 minutes). Default is 0

\U

Accept reliable link during a normal link

\V0

Report DCE speed but do not send extended responses

\V1

Report DCE speed with extended responses

\V2

Report DTE speed but do not send extended responses

\V3

Report DTE speed with extended responses

\X0

Process XON/XOFF but don’t pass through

\X1

Process XON/XOFF and pass through

\Y

Switch to reliable link from normal link

\Z

End the reliable connection and switch to normal

 

operation

 

 

Section Four - S Registers

Your modem has 29 registers, designated S0 through S28. Table 4-1 shows the registers, their functions, and their default values. Some registers can have their values changed by commands. If you use a command to change a register value, the command remains in effect until you turn off or reset your modem. Your modem then reverts to the operating characteristics specified in its non-volatile memory. Refer to Section 3 for information on how to use the AT commands to manipulate the S registers.

11

Image 12
Contents MAN018 Rev Section Two Installation Hardware InstallationSection One Introduction Unpacking Your ModemCommon Serial Ports Male connector Software Installation/ConfigurationCOM Port and Interrupt Settings SW1 Settings Devices in your computer cannot share an IRQ withUsing the Fax Capabilities of the Modem Testing Your Modem After InstallationUsing Your Modem Where To Go From HereExecuting Commands Command StructureBasic AT Commands Bold text Command FunctionCommands are echoed Low speaker volumeTouch-tone dialing DS=nExtended AT Commands Guard tone disabled Modem is set up for dial-up line operationDisable originate-only mode US setting for off-hook-to-on-hook ratioMNP/V.42/V.42bis Commands Section Four S Registers S Registers Function Range/units Default Section Five Result CodesExtended Response Codes Connect 19200/V42BIS Section Six Troubleshooting Modem does not respond to commandsModem does not dial Modem dials but does not connectModem makes a connection but no data appears on your screen 42bis/V.42/MNP2-5 does not workHigh pitch tone is heard whenever you answer the phone Section Eight Support and Service Section Nine FCC , DOC & Other NoticesFCC Compliance FCC Class B Statement DOC Compliance InformationDisclaimer, Copyright, And Other Notices