MaxTech 28 Executing Commands, Command Structure, Basic AT Commands, Bold text Command Function

Page 7

commonly asked questions and problems.

Section Three - AT Command Set

3.1 Executing Commands

Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Com- mand Mode until you dial a number and establish a connec- tion. Commands may be sent to your modem from a PC running communication software or any other terminal de- vices.

Your modem is capable of data communication at rates of: 300, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, and 115200 bps. Make sure your COM port baud rate settings in your communications software is set to one of the above speeds.

3.2 Command Structure

All commands sent to the modem must begin with AT and end with ENTER. All commands may be typed in either upper or lower case, but not mixed. To make the command line more readable, spaces may be inserted between com- mands. If you omit a parameter from a command that requires one, it is just like specifying a parameter of 0. Example:

ATH [ENTER]

This command causes your modem to hang up.

3.3 Basic AT Commands

In the following listings, all default settings are printed

in bold text.

Command Function

AManually answer incoming call.

A/

Repeat last command executed. Do not precede A/

 

with AT or follow with ENTER.

B0

CCITT mode

B1

Bell mode

B2

Autoscan mode

B3

CCITT V.23 mode only

B4

300 bps connection only

B5

1200 bps connection only

6

Image 7
Contents MAN018 Rev Unpacking Your Modem Section Two InstallationHardware Installation Section One IntroductionSoftware Installation/Configuration Common Serial Ports Male connector COM Port and Interrupt Settings Devices in your computer cannot share an IRQ with SW1 SettingsWhere To Go From Here Using the Fax Capabilities of the ModemTesting Your Modem After Installation Using Your ModemBold text Command Function Executing CommandsCommand Structure Basic AT CommandsDS=n Commands are echoedLow speaker volume Touch-tone dialingExtended AT Commands US setting for off-hook-to-on-hook ratio Guard tone disabledModem is set up for dial-up line operation Disable originate-only modeMNP/V.42/V.42bis Commands Section Four S Registers Section Five Result Codes S Registers Function Range/units DefaultExtended Response Codes Connect 19200/V42BIS Modem dials but does not connect Section Six TroubleshootingModem does not respond to commands Modem does not dial42bis/V.42/MNP2-5 does not work Modem makes a connection but no data appears on your screenHigh pitch tone is heard whenever you answer the phone Section Nine FCC , DOC & Other Notices Section Eight Support and ServiceFCC Compliance DOC Compliance Information FCC Class B StatementDisclaimer, Copyright, And Other Notices