MaxTech 28, 800 user manual Section Five Result Codes, S Registers Function Range/units Default

Page 13

 

 

Table 4-1 S - Registers

 

Register

Function

Range/units Default

S0

Auto-answer Ring

0-255/rings

0

S1

Ring counter

0-255/rings

0

S2

Escape code character

0-127/ASCII

43

S3

Carriage return character

0-127/ASCII

13

S4

Line feed character

0-127/ASCII

10

S5

Backspace character

0-32, 127/ASCII

8

S6

Dial tone wait time

2-255 /seconds

2

S7

Remote carrier wait time

1-255/seconds

50

S8

Comma pause time

0-255/seconds

2

S9

Carrier detect response time 1-255/0.1 second

6

S10

Carrier loss time

1-255/0.1second

14

S11

Touch-tone dialing speed

50-255/0.001 second 95

S12

Escape character guard time 0-255/0.02 second

50

S13

Reserved

 

 

S14

Echo, response, dialing,

Bit-mapped register

138

 

originate/answer

 

 

S15

Reserved

 

 

S16

Modem tests

Bit-mapped register

0

S17

Reserved

 

 

S18

Length of modem tests

0-255 /seconds

0

S19-20Reserved

 

 

S21

CTS, DTR, DCD, DSR

Bit-mapped register

4

 

and Long Space Disconnect

 

 

S22

Speaker and response

Bit-mapped register

117

S23

Remote Digital Loopback

Bit-mapped register

55

 

Request, data rate, parity

 

 

S24

Sleep mode timer

0-255/ seconds

0

S25

DTR delay

0-255 /0.01 second

5

S26

RTS/CTS delay interval

0-255 /0.01 second

1

S27

Asynchronous/Bell

Bit-mapped register

73

 

CCITT Modes

 

 

S28

Make/break ratio

Bit-mapped register

0

 

 

 

 

 

Section Five - Result Codes

BASIC RESPONSE CODES

OK

0

NO DIALTONE

6

CONNECT

1

BUSY

7

RING

2

NO ANSWER

8

NO CARRIER

3

CONNECT 2400

10

ERROR

4

CONNECT 4800

11

CONNECT 1200

5

CONNECT 7200

12

12

Image 13
Contents MAN018 Rev Hardware Installation Section Two InstallationSection One Introduction Unpacking Your ModemSoftware Installation/Configuration Common Serial Ports Male connectorCOM Port and Interrupt Settings Devices in your computer cannot share an IRQ with SW1 SettingsTesting Your Modem After Installation Using the Fax Capabilities of the ModemUsing Your Modem Where To Go From HereCommand Structure Executing CommandsBasic AT Commands Bold text Command FunctionLow speaker volume Commands are echoedTouch-tone dialing DS=nExtended AT Commands Modem is set up for dial-up line operation Guard tone disabled Disable originate-only mode US setting for off-hook-to-on-hook ratioMNP/V.42/V.42bis Commands Section Four S Registers Section Five Result Codes S Registers Function Range/units DefaultExtended Response Codes Connect 19200/V42BIS Modem does not respond to commands Section Six TroubleshootingModem does not dial Modem dials but does not connect42bis/V.42/MNP2-5 does not work Modem makes a connection but no data appears on your screenHigh pitch tone is heard whenever you answer the phone Section Nine FCC , DOC & Other Notices Section Eight Support and ServiceFCC Compliance DOC Compliance Information FCC Class B StatementDisclaimer, Copyright, And Other Notices