MaxTech 28, 800 user manual MNP/V.42/V.42bis Commands

Page 11

%Ln

Set transmit level to -ndBm Default = 12.(n=0-15)

%M0

Autodetect V.34 and V.FC negotiation signals

%M1

Autodetect V.34 negotiation signals only

%M2

Autodetect V.FC negotiation signals only

%P0

Disable Power-on Auto-connect

%P1

Enable Power-on Auto-connect

%S0

Disable Call-back Security

%S1

Enable Call-back Security with password check

%S2

Enable Password check only

\P=x

Stores password x (x = ASCII characters 1 through

 

127 excluding “?”, maximum 7 characters) into non-

 

volatile RAM

 

 

MNP/V.42/V.42bis Commands

%An

Set auto-reliable fallback character to n (n = 0 to 127).

 

Requires the \C2 setting

%C0

Disable V.42bis/MNP Class 5 data compression

%C1

Enable V.42bis/MNP Class 5 data compression

\A0

64-character maximum MNP block size

\A1

128-character maximum MNP block size

\A2

192-character maximum MNP block size

\A3

256-character maximum MNP block size

\Bn

Send a 1/10 second line break to the modem (n = 1- 9).

 

At normal connect, the default is 3

\C0

Do not buffer data during LAPM/MNP

 

handshaking

\C1

Buffer all data for 4 seconds, until receiving 200

 

characters or until a packet is detected

\C2

Do not buffer data; switch to normal mode when

 

fallback character is detected

\E0

Do not echo data during a normal link

\E1

Echo data during a normal link

\G0

Disable DCE flow control

\G1

Enable DCE flow control

\J0

Disable serial port data rate adjustment (keep high

 

data rate between DTE and modem, regardless of

 

modem-to-modem data rate)

\J1

Enable serial port data rate adjustment so serial data

 

rate automatically adjusts to match the modem-to-

 

modem data rate

 

 

10

Image 11
Contents MAN018 Rev Unpacking Your Modem Section Two InstallationHardware Installation Section One IntroductionSoftware Installation/Configuration Common Serial Ports Male connectorCOM Port and Interrupt Settings Devices in your computer cannot share an IRQ with SW1 SettingsWhere To Go From Here Using the Fax Capabilities of the ModemTesting Your Modem After Installation Using Your ModemBold text Command Function Executing CommandsCommand Structure Basic AT CommandsDS=n Commands are echoedLow speaker volume Touch-tone dialingExtended AT Commands US setting for off-hook-to-on-hook ratio Guard tone disabledModem is set up for dial-up line operation Disable originate-only modeMNP/V.42/V.42bis Commands Section Four S Registers Section Five Result Codes S Registers Function Range/units DefaultExtended Response Codes Connect 19200/V42BIS Modem dials but does not connect Section Six TroubleshootingModem does not respond to commands Modem does not dialHigh pitch tone is heard whenever you answer the phone Modem makes a connection but no data appears on your screen42bis/V.42/MNP2-5 does not work FCC Compliance Section Eight Support and ServiceSection Nine FCC , DOC & Other Notices DOC Compliance Information FCC Class B StatementDisclaimer, Copyright, And Other Notices