MaxTech 28, 800 user manual Extended AT Commands

Page 9

O1

Return to Data Mode and initiate an equalizer retrain

O2

Same as O1 with speed fall forward

O3

Same as O1 with speed fall backward

PSet Pulse dial as default

Q0

Modem sends responses

Q1

Modem does not send responses

Sr?

Read and display value in register r.

Sr=n

Set register r to value n (n = 0-255).

T

Set Tone Dial as default

V0

Numeric responses

V1

Word responses

X0

Hayes Smartmodem 300 compatible responses/blind

 

dialing

X1

Same as X0 plus all CONNECT responses/blind dialing

X2

Same as X1 plus dial tone detection

X3

Same as X1 plus busy detection/blind dialing

X4

All responses and dial tone and busy signal detection

Y0

Modem does not send or respond to break signals

Y1

Modem sends break signal for four seconds before

 

disconnecting

Z0

Reset and retrieve active profile 0

Z1

Reset and retrieve active profile 1

 

Extended AT Commands

&C0

Force Carrier Detect Signal High (ON)

&C1

Turn on CD when remote carrier is present

&D0

Modem ignores the DTR signal

&D1

Modem returns to Command Mode after DTR toggle

&D2

Modem hangs up, returns to the Command Mode after

 

DTR toggle

&D3

Resets modem after DTR toggle

&E0

Disable automatic fall forward/back

&E1

Enable automatic fall forward/back

&F0

Recall factory default configuration (V.42bis/

 

hardware flow control enabled)

&F1

Recall factory default with software flow control

 

enabled

&F2

Recall factory default with hardware flow control

 

enabled (same as &F)

&F3

Same as &F1 except for Macintosh computers (&F1

8

Image 9
Contents MAN018 Rev Hardware Installation Section Two InstallationSection One Introduction Unpacking Your ModemSoftware Installation/Configuration Common Serial Ports Male connectorCOM Port and Interrupt Settings Devices in your computer cannot share an IRQ with SW1 SettingsTesting Your Modem After Installation Using the Fax Capabilities of the ModemUsing Your Modem Where To Go From HereCommand Structure Executing CommandsBasic AT Commands Bold text Command FunctionLow speaker volume Commands are echoedTouch-tone dialing DS=nExtended AT Commands Modem is set up for dial-up line operation Guard tone disabledDisable originate-only mode US setting for off-hook-to-on-hook ratioMNP/V.42/V.42bis Commands Section Four S Registers Section Five Result Codes S Registers Function Range/units DefaultExtended Response Codes Connect 19200/V42BIS Modem does not respond to commands Section Six TroubleshootingModem does not dial Modem dials but does not connectModem makes a connection but no data appears on your screen 42bis/V.42/MNP2-5 does not workHigh pitch tone is heard whenever you answer the phone Section Eight Support and Service Section Nine FCC , DOC & Other NoticesFCC Compliance DOC Compliance Information FCC Class B StatementDisclaimer, Copyright, And Other Notices