Tank Fitting

®

Tank Fitting

Ball Valve

Pressure Transducer

2.Figure5 Connecting5 - Tank Mountingthe FPM100of the Pressure Transducer with Recommended Ball Value

The FPM100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer to Section 2.5.1), and 2) the pressure transducer connections, which are described in Section 2.5.2.

2.5.1 NMEA 2000® Connection

The NMEA 2000® connector can be found on the side of the enclosure. The NMEA 2000® connector is a round five pin male connector (see Figure 6). You connect the FPM100 to an NMEA 2000® network using a Maretron NMEA 2000® cable (or an NMEA 2000® compatible cable) by connecting the female end of the cable to the FPM100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000® network in the same manner. The FPM100 is designed such that you can plug or unplug it from an NMEA 2000® network while the power to the network is connected or disconnected. Please follow recommended practices for installing NMEA 2000® network products.

Revision 1.3

Page 7

Image 11
Contents Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryFPM100 User’s Manual PageTable of Contents Table of Appendices Table of Figures1.2 Firmware Revision 1.3 Features1 General 1.1 Introduction1.5 Quick Install 1.4 FPM100 Accessories1.6.2 Accuracy of Tank Level Measurement 1.6 Theory of OperationFigure 1 - Graph of Transducer Accuracy vs. Tank Depth 2 Installation2.1 Unpacking the Box 2.4.1 Pressure Measurement Applications 2.2 Choosing a Mounting Location2.3 Mounting the FPM100 2.4 Mounting the Pressure TransducerFigure 4 - Fluid Level Measurement with Pressure Transducer 2.4.2 Tank Level Measurement ApplicationsTank Fitting Ball Valve Pressure Transducer 2.5.1 NMEA 2000 Connection2.5.2 Pressure Transducer Connections Figure 6 - NMEA 2000 Connector Face ViewsPin # Signal Name Figure 7 - Pressure Transducer Connection Diagram3.2.1 Configuring Instance 3 Configuring the FPM1003.1 Configuring Channel Mode 3.2 Configuring a Channel in Pressure/Vacuum Mode3.2.4 Configuring Pressure at 20mA 3.3 Configuring a Channel in Tank Mode3.2.2 Configuring Label 3.2.3 Configuring Pressure at 4mA3.3.5 Tank Levels Calibration 3.3.2 Configuring Pressure at 4mA3.3.3 Configuring Pressure at 20mA 3.3.4 Configuring Tank Capacity3.3.5.2 Custom Calibration 3.3.6 Configuring Tank NumberFigure 8 - Empty Tank Depth and Full Tank Depth Parameters 3.3.5.1.3 Fluid Density3.3.8 Configuring Data Damping Period 4 Maintenance3.3.7 Configuring Tank Type Troubleshooting Procedure 5 TroubleshootingSymptom Specifications Pressure/Vacuum Mode 6 Technical SpecificationsFigure 9 - Troubleshooting Guide Specifications Tank Level ModeEnvironmental 7 Technical SupportElectrical MechanicalFigure 10 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingFPM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing