Maretron 1.4 FPM100 Accessories, Quick Install, FPM100 User’s Manual, Page, Revision

Page 6
1.4FPM100 Accessories

FPM100 User’s Manual

o16 programmable tank types including Fuel, Fresh Water, Waste Water o Programmable tank number(s) up to 16 per tank type

o Programmable tank capacity

1.4FPM100 Accessories

Maretron offers the following accessories for the FPM100:

PT-V-0-1BAR-01 Pressure Transducer Vacuum to 1 Bar (14.5 PSI)

PT-0-3PSI-01 Pressure Transducer 0 to 3 PSI (0.21 bar)

PT-0-5PSI-01 Pressure Transducer 0 to 5 PSI (0.34 bar)

PT-0-10PSI-01 Pressure Transducer 0 to 10 PSI (0.69 bar)

PT-0-50PSI-01 Pressure Transducer 0 to 50 PSI (3.45 bar)

PT-0-100PSI-01 Pressure Transducer 0 to 100 PSI (6.89 bar)

PT-0-300PSI-01 Pressure Transducer 0 to 300 PSI (20.68 bar)

PT-0-500PSI-01 Pressure Transducer 0 to 500 PSI (34.47 bar)

PT-0-1000PSI-01 Pressure Transducer 0 to 1000 PSI (68.95 bar)

PT-0-3000PSI-01 Pressure Transducer 0 to 3000 PSI (206.84 bar)

PT-0-5000PSI-01 Pressure Transducer 0 to 5000 PSI (344.74 bar)

PT-SNUB-01

Pressure Snubber

WARNING

Maretron pressure transducers are not approved for use with gasoline. If you wish to use the FPM100 to monitor pressures or levels of gasoline, you must obtain a pressure transducer that is approved for use with gasoline.

1.5 Quick Install

Installing the Maretron FPM100 involves the following steps. Please refer to the individual sections for additional details.

1.Unpack the Box (Section 2.1)

2.Choose a Mounting Location (Section 2.2)

3.Mount the FPM100 (Section 2.3)

4.Connect the FPM100 (Section 2.4)

5.Configure or Program the Mode for each Channel (Section 3.1)

6.For each channel in Pressure/Vacuum mode:

oSet the channel’s instance (Section 3.2.1)

oSet the channel’s source (Section 3.2.5)

oConfigure the Pressure at 4mA (Section 3.2.3)

oConfigure the Pressure at 20mA (Section 3.2.4)

7.For each channel in Tank mode:

oConfigure or Program the Tank Type (Section 3.1)

oConfigure or Program the Tank Number (Section 3.3.6) o Configure or Program Tank Capacity (Section 3.3.4)

Page 2

Revision 1.3

Image 6
Contents Revision Copyright 2012 Maretron, LLP All Rights Reserved RevisionPage Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZPage Revision HistoryFPM100 User’s Manual RevisionTable of Contents Table of Figures Table of Appendices1.1 Introduction 1.3 Features1 General 1.2 Firmware Revision1.4 FPM100 Accessories 1.5 Quick Install1.6 Theory of Operation 1.6.2 Accuracy of Tank Level Measurement2 Installation 2.1 Unpacking the BoxFigure 1 - Graph of Transducer Accuracy vs. Tank Depth 2.4 Mounting the Pressure Transducer 2.2 Choosing a Mounting Location2.3 Mounting the FPM100 2.4.1 Pressure Measurement Applications2.4.2 Tank Level Measurement Applications Figure 4 - Fluid Level Measurement with Pressure Transducer2.5.1 NMEA 2000 Connection Tank Fitting Ball Valve Pressure TransducerFigure 7 - Pressure Transducer Connection Diagram Figure 6 - NMEA 2000 Connector Face ViewsPin # Signal Name 2.5.2 Pressure Transducer Connections3.2 Configuring a Channel in Pressure/Vacuum Mode 3 Configuring the FPM1003.1 Configuring Channel Mode 3.2.1 Configuring Instance3.2.3 Configuring Pressure at 4mA 3.3 Configuring a Channel in Tank Mode3.2.2 Configuring Label 3.2.4 Configuring Pressure at 20mA3.3.4 Configuring Tank Capacity 3.3.2 Configuring Pressure at 4mA3.3.3 Configuring Pressure at 20mA 3.3.5 Tank Levels Calibration3.3.5.1.3 Fluid Density 3.3.6 Configuring Tank NumberFigure 8 - Empty Tank Depth and Full Tank Depth Parameters 3.3.5.2 Custom Calibration4 Maintenance 3.3.7 Configuring Tank Type3.3.8 Configuring Data Damping Period 5 Troubleshooting SymptomTroubleshooting Procedure Specifications Tank Level Mode 6 Technical SpecificationsFigure 9 - Troubleshooting Guide Specifications Pressure/Vacuum ModeMechanical 7 Technical SupportElectrical Environmental8 Installation Template Figure 10 - Mounting Surface Template9 Maretron 2 Year Limited Warranty Warranty Return ProcedureAppendix A - NMEA 2000 Interfacing Appendix A - NMEA 2000 InterfacingFPM100 NMEA 2000 Periodic Data Transmitted PGNs Page A1