Maretron Technical Support, Electrical, Mechanical, Environmental, FPM100 User’s Manual, Page

Page 20
Electrical

FPM100 User’s Manual

Electrical

Parameter

Value

Operating Voltage

9 to 32 Volts

Power Consumption

400mA

Load Equivalence Number (LEN)

8

Reverse Battery Protection

Yes

Load Dump Protection

Yes

Comment

DC Voltage

Maximum Current Drain

NMEA 2000® Spec. (1LEN = 50mA) Indefinitely

Energy Rated per SAE J1113

Mechanical

Parameter

Value

Size

3.50” x 4.20” x 2.03”

 

(88.9mm x 106.7mm x 51.6mm)

Weight

13 oz. (368.5 g)

Comment

Including Flanges for Mounting

Environmental

Parameter

IEC 60945 Classification

Degree of Protection

Operating Temperature

Storage Temperature

Relative Humidity

Vibration

Solar Radiation

Corrosion (Salt Mist)

Electromagnetic Emission

Electromagnetic Immunity

Safety Precautions

Value

Exposed

IP64

-25°C to 55°C -40°C to 70°C

93%RH @40° per IEC60945-8.2

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Conducted and Radiated Emission per IEC 60945-9

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

7 Technical Support

If you require technical support for Maretron products, you can reach us in any of the following ways:

Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

support@maretron.com

World Wide Web:

http://www.maretron.com

Mail:

Maretron, LLP

 

Attn: Technical Support

 

9014 N. 23rd Ave Suite 10

 

Phoenix, AZ 85021 USA

Page 16

Revision 1.3

Image 20
Contents Revision PageRevision Copyright 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZRevision History FPM100 User’s ManualPage RevisionTable of Contents Table of Figures Table of Appendices1.3 Features 1 General1.1 Introduction 1.2 Firmware Revision1.4 FPM100 Accessories 1.5 Quick Install1.6 Theory of Operation 1.6.2 Accuracy of Tank Level MeasurementFigure 1 - Graph of Transducer Accuracy vs. Tank Depth 2 Installation2.1 Unpacking the Box 2.2 Choosing a Mounting Location 2.3 Mounting the FPM1002.4 Mounting the Pressure Transducer 2.4.1 Pressure Measurement Applications2.4.2 Tank Level Measurement Applications Figure 4 - Fluid Level Measurement with Pressure Transducer2.5.1 NMEA 2000 Connection Tank Fitting Ball Valve Pressure TransducerFigure 6 - NMEA 2000 Connector Face Views Pin # Signal NameFigure 7 - Pressure Transducer Connection Diagram 2.5.2 Pressure Transducer Connections3 Configuring the FPM100 3.1 Configuring Channel Mode3.2 Configuring a Channel in Pressure/Vacuum Mode 3.2.1 Configuring Instance3.3 Configuring a Channel in Tank Mode 3.2.2 Configuring Label3.2.3 Configuring Pressure at 4mA 3.2.4 Configuring Pressure at 20mA3.3.2 Configuring Pressure at 4mA 3.3.3 Configuring Pressure at 20mA3.3.4 Configuring Tank Capacity 3.3.5 Tank Levels Calibration3.3.6 Configuring Tank Number Figure 8 - Empty Tank Depth and Full Tank Depth Parameters3.3.5.1.3 Fluid Density 3.3.5.2 Custom Calibration3.3.8 Configuring Data Damping Period 4 Maintenance3.3.7 Configuring Tank Type Troubleshooting Procedure 5 TroubleshootingSymptom 6 Technical Specifications Figure 9 - Troubleshooting GuideSpecifications Tank Level Mode Specifications Pressure/Vacuum Mode7 Technical Support ElectricalMechanical Environmental8 Installation Template Figure 10 - Mounting Surface Template9 Maretron 2 Year Limited Warranty Warranty Return ProcedureAppendix A - NMEA 2000 Interfacing FPM100 NMEA 2000 Periodic Data Transmitted PGNsAppendix A - NMEA 2000 Interfacing Page A1