Maretron FPM100 Appendix A - NMEA 2000 Interfacing, Page A1, PGN 130314 - Actual Pressure

Page 23
Appendix A – NMEA 2000® Interfacing

®

Appendix A – NMEA 2000® Interfacing

FPM100 NMEA 2000® Periodic Data Transmitted PGNs

PGN 130314 – Actual Pressure

The FPM100 uses this PGN to provide a regular transmission of various pressures. The factory default for periodic transmission rate is once every two seconds. The transmission of this PGN can be disabled (see PGN 126208 – NMEA Request Group Function – Transmission Periodic Rate).

Field 1:SID – The sequence identifier field is used to tie related PGNs together. For example, the FPM100 will transmit identical SIDs for 130312 (Temperature) and 130311 (Environmental Parameters) to indicate that the readings are linked together (i.e., the data from each PGN was taken at the same time although they are reported at slightly different times).

2:Pressure Instance – The FPM100 sets this field to identify a particular pressure measurement from the source specified in Field 3. Every pressure measurement from a given source type on the network should have a distinct instance value, so that monitoring devices and displays can identify which measurement is which.

3:Pressure Source – This field is used to indicate the type of pressure measurement being taken. Possible values for this field include Atmospheric Pressure, Water Pressure, Steam Pressure, Compressed Air Pressure, Hydraulic Pressure, and 16 User Defined pressure sources.

4:Pressure – This field is used to indicate the pressure, whose source is specified in field 2, in units of 0.1 Pa.

6:Reserved bits – The FPM100 sets all bits in this field to a value of “1”.

PGN 127505 – Fluid Level

The FPM100 uses this PGN to indicate the attached tank’s fluid instance, fluid type, fluid level, and tank capacity.

Field 1: Fluid Instance – This field is used to identify the tank number and ranges between 0 and 15. There can be up to 16 tanks of a given type as defined by the Fluid Type field. This field is programmable through the NMEA command PGN. The FPM100 ships from the factory with a default value of zero.

2:Fluid Type – This field identifies the type of fluid contained within the tank. Currently the defined fluid types are fuel, fresh water, wastewater, live well, oil, and black water. This field is programmable through the NMEA command PGN. The FPM100 ships from the factory with a default value of 0x0 indicating “Fuel”.

3:Fluid Level – This field is used to indicate the current fluid level in percentage. The value transmitted in this field depends on the distance from the sender to the top of the fluid or tank bottom.

4:Tank Capacity – This field is used to indicate the tank capacity. This field is programmable through the NMEA command PGN. The FPM100 ships from the factory with a default value of 0xFFFFFFFF indicating “Data Not Available”.

5:Reserved – This field is reserved by NMEA; therefore, the FPM100 sets all bits to a logic 1.

Revision 1.3

Appendix A – NMEA 2000® Interfacing

Page A1
Image 23
Contents Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryFPM100 User’s Manual PageTable of Contents Table of Appendices Table of Figures1.2 Firmware Revision 1.3 Features1 General 1.1 Introduction1.5 Quick Install 1.4 FPM100 Accessories1.6.2 Accuracy of Tank Level Measurement 1.6 Theory of OperationFigure 1 - Graph of Transducer Accuracy vs. Tank Depth 2 Installation2.1 Unpacking the Box 2.4.1 Pressure Measurement Applications 2.2 Choosing a Mounting Location2.3 Mounting the FPM100 2.4 Mounting the Pressure TransducerFigure 4 - Fluid Level Measurement with Pressure Transducer 2.4.2 Tank Level Measurement ApplicationsTank Fitting Ball Valve Pressure Transducer 2.5.1 NMEA 2000 Connection2.5.2 Pressure Transducer Connections Figure 6 - NMEA 2000 Connector Face ViewsPin # Signal Name Figure 7 - Pressure Transducer Connection Diagram3.2.1 Configuring Instance 3 Configuring the FPM1003.1 Configuring Channel Mode 3.2 Configuring a Channel in Pressure/Vacuum Mode3.2.4 Configuring Pressure at 20mA 3.3 Configuring a Channel in Tank Mode3.2.2 Configuring Label 3.2.3 Configuring Pressure at 4mA3.3.5 Tank Levels Calibration 3.3.2 Configuring Pressure at 4mA3.3.3 Configuring Pressure at 20mA 3.3.4 Configuring Tank Capacity3.3.5.2 Custom Calibration 3.3.6 Configuring Tank NumberFigure 8 - Empty Tank Depth and Full Tank Depth Parameters 3.3.5.1.3 Fluid Density3.3.8 Configuring Data Damping Period 4 Maintenance3.3.7 Configuring Tank Type Troubleshooting Procedure 5 TroubleshootingSymptom Specifications Pressure/Vacuum Mode 6 Technical SpecificationsFigure 9 - Troubleshooting Guide Specifications Tank Level ModeEnvironmental 7 Technical SupportElectrical MechanicalFigure 10 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingFPM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing