Maretron FPM100 Technical Specifications, Troubleshooting Guide, Specifications Tank Level Mode

Page 19
Figure 9 – Troubleshooting Guide

®

Figure 9 – Troubleshooting Guide

If these steps do not solve your problem, please contact Maretron Technical Support (refer to Section 7 for contact information).

6 Technical Specifications

Specifications (Tank Level Mode)

ParameterValueComment

Accuracy

+/-1% FS

Exclusive of Pressure Transducer

Resolution

+/-0.33% FS

Over Full Pressure Transducer Range

Number of Tank Types

16

Fuel, Fresh Water, Waste water, Live well, Oil, etc.

Number of Tanks per Tank Type

16

16 Tanks per Tank Type Numbered 0-15

Support for Irregularly Shaped

Yes

Can be Calibrated for any Shape Tank

Tanks

 

 

Programmable Tank Capacity

Yes

Allows Displays to Calculate Amount Remaining

Specifications (Pressure/Vacuum Mode)

Parameter

Value

Comment

Accuracy

+/-1% FS

Exclusive of Pressure Transducer

Resolution

+/-0.33% FS

Over Full Pressure Transducer Range

Number of Pressure Source Types

21

Water Pressure, Atmospheric Pressure, Compressed Air

 

 

Pressure, Hydraulic Pressure, Steam Pressure, 16 User

 

 

Defined Sources

Certifications

Parameter

Comment

NMEA 2000

Level A

Maritime Navigation and Radiocommunication Equipment & Systems

IEC 61162-3

Maritime Navigation and Radiocommunication Equipment & Systems

Tested to IEC 60945

FCC and CE Mark

Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs) - See Appendix A for Details

DescriptionPGN #PGN NameDefault Rate

Periodic Data PGNs

127505

Fluid Level

0.4 Times/Second

 

130314

Actual Pressure

0.5 Times/Second

Response to Requested PGNs

126464

PGN List (Transmit and Receive)

N/A

 

126996

Product Information

N/A

 

126998

Configuration Information

N/A

Protocol PGNs

059392

ISO Acknowledge

N/A

 

059904

ISO Request

N/A

 

060928

ISO Address Claim

N/A

 

065240

ISO Address Command

N/A

 

126208

NMEA

N/A

Maretron Proprietary PGNs

128720

Configuration

N/A

Revision 1.3

Page 15

Image 19
Contents Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryFPM100 User’s Manual PageTable of Contents Table of Appendices Table of Figures1.2 Firmware Revision 1.3 Features1 General 1.1 Introduction1.5 Quick Install 1.4 FPM100 Accessories1.6.2 Accuracy of Tank Level Measurement 1.6 Theory of Operation2.1 Unpacking the Box 2 InstallationFigure 1 - Graph of Transducer Accuracy vs. Tank Depth 2.4.1 Pressure Measurement Applications 2.2 Choosing a Mounting Location2.3 Mounting the FPM100 2.4 Mounting the Pressure TransducerFigure 4 - Fluid Level Measurement with Pressure Transducer 2.4.2 Tank Level Measurement ApplicationsTank Fitting Ball Valve Pressure Transducer 2.5.1 NMEA 2000 Connection2.5.2 Pressure Transducer Connections Figure 6 - NMEA 2000 Connector Face ViewsPin # Signal Name Figure 7 - Pressure Transducer Connection Diagram3.2.1 Configuring Instance 3 Configuring the FPM1003.1 Configuring Channel Mode 3.2 Configuring a Channel in Pressure/Vacuum Mode3.2.4 Configuring Pressure at 20mA 3.3 Configuring a Channel in Tank Mode3.2.2 Configuring Label 3.2.3 Configuring Pressure at 4mA3.3.5 Tank Levels Calibration 3.3.2 Configuring Pressure at 4mA3.3.3 Configuring Pressure at 20mA 3.3.4 Configuring Tank Capacity3.3.5.2 Custom Calibration 3.3.6 Configuring Tank NumberFigure 8 - Empty Tank Depth and Full Tank Depth Parameters 3.3.5.1.3 Fluid Density3.3.7 Configuring Tank Type 4 Maintenance3.3.8 Configuring Data Damping Period Symptom 5 TroubleshootingTroubleshooting Procedure Specifications Pressure/Vacuum Mode 6 Technical SpecificationsFigure 9 - Troubleshooting Guide Specifications Tank Level ModeEnvironmental 7 Technical SupportElectrical MechanicalFigure 10 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingFPM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 Interfacing