Liebert GXT3-10000T220 user manual Inspection, Required Setup Equipment, Unpacking

Page 10

Unpacking the UPS and Site Preparation

2.0UNPACKING THE UPS AND SITE PREPARATION

2.1Inspection

Upon receiving your Liebert® GXT3-10000T220, examine the packaging for any signs of mishandling or damage. While removing shipping materials, inspect the UPS for damage. If any damage is noted, notify your local Liebert representative and your carrier.

2.2Required Setup Equipment

The following tools are required to set up your Liebert GXT3-10000T220:

pallet jack

utility knife or scissors

screwdrivers—Phillips and straight blade

2.3Unpacking

Exercise care when removing the packaging to avoid damaging the UPS. Check all packaging to ensure that no items are discarded. Remove the packaging following the sequence in Figure 3.

! WARNING

The UPS is heavy and will roll when on an incline. When removing the unit from its shipping pallet, use at least two persons.

1.Using a pallet jack, move the Liebert GXT3-10000T220 near its installation site.

2.Unlock all the snaps securing the shipping case to the shipping pallet.

3.Lift the shipping case off the UPS.

4.Remove the EPE packing cushions from around the Liebert GXT3-10000T220.

5.Remove the ramp from the front and slip into the slot on the front of the shipping pallet.

6.Roll the UPS off the shipping pallet.

Figure 3 Unpacking

Plywood

Case

Packing Cushion

(EPE)

GXT3 T220

UPS

Ramp in slot

on shipping pallet

Unlock

Ramp

Storage

If the UPS will be stored, it must be placed indoors in a clean, dry area. Protect all the equipment, including its batteries, from extreme temperatures, high humidity, spills and other damaging conditions. Refer to Table 9 for permissible environmental conditions for storage.

Handling

The equipment must be kept upright at all times and handled with care. It may be damaged if dropped or subjected to severe impact.

6

Image 10
Contents Liebert GXT3-10000T220 Page Table of Contents Maintenance CommunicationImportant Safety Instructions Page Leakage Current Information for the Protection of the EnvironmentIntroduction and System Description Liebert GXT3-10000T220 control panelDevice Overview Type Model # Nominal powerOverview of UPS devices and batteries Unpacking Required Setup EquipmentInspection Unpacking the UPS and Site PreparationFloor Loading Access to AreaEnvironmental Conditions Inventory ListSuggested Cable Sizes InstallationElectrical preparations External Protection and Isolating DevicesTerminal Blocks for UPS Connecting Utility and LoadExternal Electrical Connections Rear Panel Cable Entry CoverInput and Output Connection Requirements Jumper removed for clarityExternal Battery Cabinets Connecting Power CablesCabinet Block Diagram OperationControls and Messages Lighted LEDs Fault Battery UPS On BypassControl Panel Flashing LEDMenu tree Displayed text-system block and main menu Control Battery Setup ParametersBattery setup parameters Test ReportFault indicators Fault IndicatorsFault Cause Corrective steps UPS Shutdown Procedure Initial UPS Startup ProcedureMaintenance Bypass Procedure Battery Test Return from Maintenance BypassMaintenance Breaker, Off Position Self-TestsMaintenance Test, Replacement and Disposal of BatteriesCleaning Replacement battery packDry Contact Any Mode ShutdownCommunication Interface Port CommunicationLow Battery Battery Mode ShutdownOn Battery Liebert IntelliSlot Communication CardsRepo switch connection diagram Remote Emergency Power OffLiebert MultiLink Troubleshooting guide TroubleshootingProblem Possible Cause Solution Specifications Liebert GXT3 specificationsDimensions, W x D x H, in. mm Battery cabinet specificationsTypical battery run times for the Liebert GXT3-10000T230 Internal Battery ParametersProduct Warranty Registration Twor k Ne tIs t Care