Liebert GXT3-10000T220 user manual Device Overview, Overview of UPS devices and batteries

Page 9

Introduction and System Description

1.1Device Overview

The following table provides an overview of the various versions of the device:

Table 1

Overview of UPS devices and batteries

 

 

 

 

 

 

Type

Model #

Nominal power

 

 

 

UPS with Integrated Battery

Liebert® GXT3-10000T220

10000VA/90000W

Battery Cabinet

Liebert GXT3-240TBATTCE

Figure 2 Liebert® GXT3-10000T220front and rear views

Control Panel

Liquid Crystal

Display

Push Button

Controls

Ventilation

Louvers

External

Battery

Connector

Liebert IntelliSlot®

Communication

Card slot

USB Port

Dry Contacts

REPO

Hardwire Input and Output

Connectors (Protective Cover Shown)

Maintenance Bypass Breaker (cover removed for clarity)

Input

Circuit

Breaker

Bypass

Circuit

Breaker

Output

Circuit

Breaker

5

Image 9
Contents Liebert GXT3-10000T220 Page Table of Contents Communication MaintenanceImportant Safety Instructions Page Information for the Protection of the Environment Leakage CurrentLiebert GXT3-10000T220 control panel Introduction and System DescriptionType Model # Nominal power Device OverviewOverview of UPS devices and batteries Inspection Required Setup EquipmentUnpacking Unpacking the UPS and Site PreparationEnvironmental Conditions Access to AreaFloor Loading Inventory ListElectrical preparations InstallationSuggested Cable Sizes External Protection and Isolating DevicesExternal Electrical Connections Connecting Utility and LoadTerminal Blocks for UPS Rear Panel Cable Entry CoverJumper removed for clarity Input and Output Connection RequirementsConnecting Power Cables External Battery CabinetsCabinet Operation Block DiagramControl Panel Fault Battery UPS On BypassControls and Messages Lighted LEDs Flashing LEDMenu tree Displayed text-system block and main menu Battery setup parameters Battery Setup ParametersControl Test ReportFault Indicators Fault indicatorsFault Cause Corrective steps Initial UPS Startup Procedure UPS Shutdown ProcedureMaintenance Bypass Procedure Maintenance Breaker, Off Position Return from Maintenance BypassBattery Test Self-TestsCleaning Test, Replacement and Disposal of BatteriesMaintenance Replacement battery packCommunication Interface Port Any Mode ShutdownDry Contact CommunicationOn Battery Battery Mode ShutdownLow Battery Liebert IntelliSlot Communication CardsRemote Emergency Power Off Repo switch connection diagramLiebert MultiLink Troubleshooting Troubleshooting guideProblem Possible Cause Solution Liebert GXT3 specifications SpecificationsTypical battery run times for the Liebert GXT3-10000T230 Battery cabinet specificationsDimensions, W x D x H, in. mm Internal Battery ParametersProduct Warranty Registration Is t Ne tTwor k Care