Lantronix manual Wlan Configuration XPress DR+W only, Device Address Table

Page 58

 

 

Chapter 6: Configuration Using Web Manager

Endpoint Configuration

 

 

 

Local Port

Enter the local port number.

 

 

 

 

 

 

Remote Port

Enter the port number of the remote device.

 

 

 

 

 

Remote Host

Enter the IP address of the remote device.

 

 

 

 

 

Device Address Table

The table is enabled when Datagram Type is set to FD. Enter

 

 

values between 1 and 255 to identify units on the local

 

 

network of device servers.

 

 

Note: Lantronix Tech Support supports Datagram type 01.

 

 

Datagram Type FD is for OEM use.

 

3.When finished, click the OK button.

4.To save and reboot, click Apply Settings on the main menu.

WLAN Configuration (XPress DR+W only)

Once you have initially configured the wireless unit's network and WLAN settings, you can modify them in Web Manager. For information on initial configuration, see Chapter 4: XPress DR+W.

Without adequate protection, a wireless LAN is susceptible to access by unauthorized users.

The XPress DR+W WLAN Settings menu permits the following actions:

‹Configuration of the wireless network profile available for activation

‹Configuration of the wireless network security settings

‹Configuration of advanced settings such as radio power management

Note: Due to regulations, the country-specific setting has been removed from the setup menu and Web Manager. However, we provide a separate utility for changing the Country/Zone setting. The utility is called SetZone and is included on the XPress DR+W CD. It is also available for download from the Lantronix web site.

The syntax is SetZone <IP address> [<zone abbreviation>]

Leaving the zone blank causes the utility to report the current setting only. Following are valid zone abbreviations. These settings are consistent with IEEE802.11b/g zones:

US=United States

CA=Canada

FR=France

SP=Spain

JP=Japan

OT=Others, such as Europe (excluding France), Asia, Africa, and Australia

XPress DR+ User Guide

58

Image 58
Contents XPress DR+ User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersDate Rev Comments Contents Configuration Using Web Manager Using DeviceInstallerContents Setup Mode Server Configuration Configuration Using Telnet or Serial Port Setup ModeSetup Mode Channel Configuration Setup Mode Advanced Settings Expert Settings Option 5Troubleshooting and Technical Support Firmware UpgradesMonitor Mode Appendix D Binary to Hexadecimal Conversions 108Appendix F Warranty 115 Index 116 FiguresTables Summary of Chapters Using This GuidePurpose and Audience Chapter DescriptionUsing This Guide Additional DocumentationIntroduction Product DescriptionIntroduction XPress DR+ FrontIndustrial Automation Protocols Network Protocols Serial TunnelingXPress DR+ Application Examples Example of Serial TunnelingIP Address Addresses and Port NumbersHardware Address Port NumbersConfiguration Methods Lantronix Web Manager. See Configuration Using Web ManagerWhats in the Box? Installation and HardwarePhysically Connecting the XPress DR+ What Must the User Provide?Installation and Hardware XPress DR+ Front PanelSerial Interface Front of XPress DR+Serial Screw Terminal Pinout for RS422 4-Wire Screw Terminal Serial ConnectorsRJ45 Serial Connector Pinouts Serial Screw Terminal Pinout for RS485 2-WirePin RS-232 to Serial RJ45 Cable P/N DTE, 9-Pin XPress DR+ Female Serial RJ45Typical RJ45 Connector Ethernet Interface SignalsEthernet Interface Reset Switch Power RequirementsMulti-Drop Ethernet Connections RXD Activity LED TXD Activity LED Ethernet Link LED LEDsEthernet Activity LED Status Meaning DimensionsXPress DR+ LED Functions Wall Mount Bracket Product Information LabelApplication Examples XPress DR+WSerial Tunneling Network Serial Tunneling Infrastructure Ad Hoc NetworkXPress DR+W Physically Connecting the XPress DR+W Ad Hoc XPress DR+W ConnectionTypical XPress DR+W Configuration Front Panel DescriptionRequired Information for Initial Configuration XPress DR+W LED FunctionsWlan Settings Installing the XPress DR+W for Initial ConfigurationServer Configuration Option IP Address Subnet Mask GatewaySet Gateway IP Address Network Mode XPress DR+W onlyBootP/DHCP/AutoIP options Options BitNetmask Number of Bits for Host Part Wlan Configuration OptionChange Telnet Configuration Password Change Dhcp Device NameNetwork Name Ssid TopologyAdhoc Network Channel Hex Key Type Encryption KeyPassphrase WPA WPA2/802.11i Fixed or Automatic Data RateNext Steps Transmission Data RateTo install DeviceInstaller Using DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressUsing DeviceInstaller Accessing the XPress DR+ Using DeviceInstallerViewing the Current Configuration To view the units current settingsSetting Description Supports Http Setup Supports ConfigurablePins Supports Dynamic IPAccessing XPress DR+ Using DeviceInstaller Configuration Using Web ManagerConfiguration Using Web Manager Network Configuration Lantronix Web ManagerAutoIP Automatic IP Address ConfigurationTo assign an IP address automatically Dhcp Host NameDefault Gateway Server ConfigurationStatic IP Address Configuration To assign an IP address manuallyTo configure the units device server settings Server ConfigurationAdvanced To configure the units host list Host List Configuration0x77FE Server Port MTU Size Retry Settings Channel ConfigurationSerial Settings To configure the channel’s serial settingsPort Settings ChannelFlush Input Buffer Serial to Network Pack ControlFlush Output Buffer Network to Serial Connection Settings TCP To configure a channel’s TCP settings Endpoint Configuration Connect Mode Passive Connection Connect Mode Active Connection Connect ProtocolTo configure a channel’s UDP settings Connection Settings UDPDisconnect Mode Common OptionsDatagram Mode Datagram TypeWlan Configuration XPress DR+W only Device Address TableTo configure the XPress DR+W’s Wlan settings Wlan Settings Ad Hoc Network TypeNetwork Type Wireless Network ConfigurationNetwork Name Ssid ChannelWEP Options Wireless Network SecurityWPA Options Advanced Settings Applying SettingsApplying Factory Defaults WPA2/802.11i OptionsConfiguration Using Telnet or Serial Port Setup Mode Accessing Setup ModeSerial Port Connection Configuration Using Telnet or Serial Port Setup ModeTo establish a Telnet connection Exiting Setup Mode To exit setup modeSetup Mode Server Configuration Setup Mode Server Configuration Dhcp Name Channel 1 Option 1 and Channel 2 Option Setup Mode Channel ConfigurationBaudrate Mode Option Interface ModeSetup Mode Channel Configuration Common I/F Mode Setting Binary HexFlow Control Option Hex FlowPort Number Port Numbers Reserved forConnect Mode Connect Mode OptionResponse Incoming ConnectionActive Startup Connection Autostart AutomaticHostlist Datagram Type Modem ModeTo enable the hostlist Directed UDPMessage Meaning Modem Mode Function Command Modem Mode CommandsAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeRemote IP Address Remote Port Disconnect Mode OptionDisconnect Mode Options DisConnModePack Control Flush Mode Buffer FlushingOption Trailing Characters DisConnTime Inactivity TimeoutPacking Interval Send CharactersSend Characters Channel Port PasswordWlan Settings XPress DR+W Only Telnet Terminal TypeTopology 0=Infrastructure, 1=Adhoc 0 ? WEP WEP64 or 13 WEP128 bytes and limits the number of key TX Data rate 0=fixed, 1=auto fallback 1 ? Enable Power Management ARP Cache timeout in seconds Setup Mode Advanced SettingsExpert Settings Option Disable Monitor Mode at bootupSetup Mode Advanced Settings Security Settings OptionEnable alternate MAC Http Port NumberDisable Tftp Firmware Upgrade Disable SnmpDisable Telnet Setup Disable Port 77FE HexDefault Settings Option Wlan Settings XPress DR+W only Expert SettingsSecurity Settings Topology AdHoc Network NameObtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface ROM FileFirmware Upgrades Using Tftp Command Line InterfaceTo recover firmware Firmware Upgrades Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsMonitor Mode Commands Monitor ModeCommand Command Name Function G0, G1, ....,Ge, GfCommand Response Codes Response MeaningProblem/Message Reason Solution Troubleshooting and Technical SupportProblems and Error Messages Problems and Error MessagesTroubleshooting and Technical Support XPress DR+ User Guide 101 Technical Support Technical Support Europe, Middle East, and AfricaAppendix a Technical Specifications XPress DR+ and XPress DR+W SpecificationsXPress DR+W Wireless Specifications Appendix a Technical SpecificationsCategory Ieee 802.11b/g Lantronix P/N Description Appendix B Lantronix Cables and AdaptersApplications Appendix C Alternative Methods of Assigning an IP Address AutoIPAppendix C Alternative Methods of Assigning an IP Address ARP and TelnetTo assign a temporary IP address Conversion Table Appendix D Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorAppendix D Binary to Hexadecimal Conversions Electromagnetic Emissions and Immunity XPress DR+ Appendix E Compliance InformationDeclaration of Conformity Emissions ImmunityRadio Appendix E Compliance InformationElectromagnetic Emissions and Immunity XPress DR+W USA Federal Communications Commission FCC Notice XPress DR+W Regulatory InformationCanada Industry Canada Notice Antenna Notice Europe R&TTE Directive 99/5/EC, Wireless NoticeExposure of Humans to RF Fields Australia & New Zealand Wireless Notice Appendix F Warranty Index