Chapter 9: Setup Mode: Channel Configuration

This chapter explains how to configure a serial port.

Notes:

‹Current values display in parenthesis.

‹You must enter some values in hexadecimal notation. (See Appendix D: Binary to Hexadecimal Conversions).

Channel 1 (Option 1) and Channel 2 (Option 2)

Note: Channel 1 and Channel 2 have the same defaults except for the port number (10001 for Channel 1 and 10002 for Channel 2).

Select Channel 1 (option 1) or Channel 2 (option 2) from the Change Setup menu to define how the serial port responds to network and serial communications. The following sections describe the configurable parameters within the Channel configuration menu.

Figure 9-1. Serial Port Parameters

Baudrate

The unit and attached serial device, such as a Programmable Logic Controller (PLC), must agree on a speed or baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, and 230400 baud.

Baudrate (9600) ? _

XPress DR+ User Guide

69

Image 69
Contents XPress DR+ User Guide Lantronix Corporate Headquarters Technical Support Sales OfficesDate Rev Comments Contents Using DeviceInstaller Configuration Using Web ManagerContents Configuration Using Telnet or Serial Port Setup Mode Setup Mode Server ConfigurationSetup Mode Channel Configuration Expert Settings Option 5 Setup Mode Advanced SettingsMonitor Mode Firmware UpgradesTroubleshooting and Technical Support Appendix D Binary to Hexadecimal Conversions 108Figures Appendix F Warranty 115 Index 116Tables Purpose and Audience Using This GuideSummary of Chapters Chapter DescriptionAdditional Documentation Using This GuideProduct Description IntroductionXPress DR+ Front IntroductionNetwork Protocols Serial Tunneling Industrial Automation ProtocolsExample of Serial Tunneling XPress DR+ Application ExamplesHardware Address Addresses and Port NumbersIP Address Port NumbersLantronix Web Manager. See Configuration Using Web Manager Configuration MethodsPhysically Connecting the XPress DR+ Installation and HardwareWhats in the Box? What Must the User Provide?XPress DR+ Front Panel Installation and HardwareFront of XPress DR+ Serial InterfaceRJ45 Serial Connector Pinouts Screw Terminal Serial ConnectorsSerial Screw Terminal Pinout for RS422 4-Wire Serial Screw Terminal Pinout for RS485 2-WireDTE, 9-Pin XPress DR+ Female Serial RJ45 Pin RS-232 to Serial RJ45 Cable P/NEthernet Interface Signals Typical RJ45 ConnectorEthernet Interface Power Requirements Reset SwitchMulti-Drop Ethernet Connections LEDs RXD Activity LED TXD Activity LED Ethernet Link LEDEthernet Activity LED Dimensions Status MeaningXPress DR+ LED Functions Product Information Label Wall Mount BracketXPress DR+W Application ExamplesSerial Tunneling Network Ad Hoc Network Serial Tunneling InfrastructureXPress DR+W Ad Hoc XPress DR+W Connection Physically Connecting the XPress DR+WFront Panel Description Typical XPress DR+W ConfigurationXPress DR+W LED Functions Required Information for Initial ConfigurationServer Configuration Option Installing the XPress DR+W for Initial ConfigurationWlan Settings IP Address Subnet Mask GatewayBootP/DHCP/AutoIP options Network Mode XPress DR+W onlySet Gateway IP Address Options BitChange Telnet Configuration Password Wlan Configuration OptionNetmask Number of Bits for Host Part Change Dhcp Device NameTopology Network Name SsidAdhoc Network Channel Key Type Encryption Key HexPassphrase WPA Fixed or Automatic Data Rate WPA2/802.11iTransmission Data Rate Next StepsInstalling DeviceInstaller Using DeviceInstallerTo install DeviceInstaller Assigning an IP AddressViewing the Current Configuration Accessing the XPress DR+ Using DeviceInstallerUsing DeviceInstaller To view the units current settingsSetting Description Pins Supports ConfigurableSupports Http Setup Supports Dynamic IPConfiguration Using Web Manager Accessing XPress DR+ Using DeviceInstallerConfiguration Using Web Manager Lantronix Web Manager Network ConfigurationTo assign an IP address automatically Automatic IP Address ConfigurationAutoIP Dhcp Host NameStatic IP Address Configuration Server ConfigurationDefault Gateway To assign an IP address manuallyServer Configuration To configure the units device server settingsAdvanced Host List Configuration To configure the units host list0x77FE Server Port MTU Size Serial Settings Channel ConfigurationRetry Settings To configure the channel’s serial settingsChannel Port SettingsPack Control Flush Input Buffer Serial to NetworkFlush Output Buffer Network to Serial To configure a channel’s TCP settings Connection Settings TCPConnect Mode Active Connection Connect Mode Passive ConnectionEndpoint Configuration Connect ProtocolDisconnect Mode Connection Settings UDPTo configure a channel’s UDP settings Common OptionsDatagram Type Datagram ModeDevice Address Table Wlan Configuration XPress DR+W onlyWlan Settings Ad Hoc Network Type To configure the XPress DR+W’s Wlan settingsNetwork Name Ssid Wireless Network ConfigurationNetwork Type ChannelWireless Network Security WEP OptionsWPA Options Applying Factory Defaults Applying SettingsAdvanced Settings WPA2/802.11i OptionsAccessing Setup Mode Configuration Using Telnet or Serial Port Setup ModeConfiguration Using Telnet or Serial Port Setup Mode Serial Port ConnectionTo establish a Telnet connection To exit setup mode Exiting Setup ModeSetup Mode Server Configuration Setup Mode Server Configuration Dhcp Name Setup Mode Channel Configuration Channel 1 Option 1 and Channel 2 OptionBaudrate Setup Mode Channel Configuration Interface ModeMode Option Common I/F Mode Setting Binary HexPort Number FlowFlow Control Option Hex Port Numbers Reserved forConnect Mode Option Connect ModeIncoming Connection ResponseActive Startup Autostart Automatic ConnectionHostlist To enable the hostlist Modem ModeDatagram Type Directed UDPMessage Meaning Modem Mode Commands Modem Mode Function CommandSend the Escape Sequence +++ in Modem Mode Auto Increment Source PortRemote IP Address Disconnect Mode Options Disconnect Mode OptionRemote Port DisConnModeFlush Mode Buffer Flushing Pack ControlOption Packing Interval DisConnTime Inactivity TimeoutTrailing Characters Send CharactersWlan Settings XPress DR+W Only Channel Port PasswordSend Characters Telnet Terminal TypeTopology 0=Infrastructure, 1=Adhoc 0 ? WEP WEP64 or 13 WEP128 bytes and limits the number of key TX Data rate 0=fixed, 1=auto fallback 1 ? Enable Power Management Expert Settings Option Setup Mode Advanced SettingsARP Cache timeout in seconds Disable Monitor Mode at bootupEnable alternate MAC Security Settings OptionSetup Mode Advanced Settings Http Port NumberDisable Telnet Setup Disable SnmpDisable Tftp Firmware Upgrade Disable Port 77FE HexDefault Settings Option Security Settings Expert SettingsWlan Settings XPress DR+W only Topology AdHoc Network NameUsing Tftp Graphical User Interface Firmware UpgradesObtaining Firmware Reloading Firmware ROM FileUsing Tftp Command Line Interface Firmware UpgradesTo recover firmware Firmware Upgrades Entering Monitor Mode Using the Serial Port Monitor ModeEntering Monitor Mode Using the Network Port Monitor Mode CommandsCommand Command Name Function Monitor ModeMonitor Mode Commands G0, G1, ....,Ge, GfResponse Meaning Command Response CodesProblems and Error Messages Troubleshooting and Technical SupportProblem/Message Reason Solution Problems and Error MessagesTroubleshooting and Technical Support XPress DR+ User Guide 101 Technical Support Europe, Middle East, and Africa Technical SupportXPress DR+ and XPress DR+W Specifications Appendix a Technical SpecificationsAppendix a Technical Specifications XPress DR+W Wireless SpecificationsCategory Ieee 802.11b/g Appendix B Lantronix Cables and Adapters Lantronix P/N DescriptionApplications AutoIP Appendix C Alternative Methods of Assigning an IP AddressARP and Telnet Appendix C Alternative Methods of Assigning an IP AddressTo assign a temporary IP address Converting Binary to Hexadecimal Appendix D Binary to Hexadecimal ConversionsConversion Table Scientific CalculatorAppendix D Binary to Hexadecimal Conversions Declaration of Conformity Appendix E Compliance InformationElectromagnetic Emissions and Immunity XPress DR+ Emissions ImmunityAppendix E Compliance Information RadioElectromagnetic Emissions and Immunity XPress DR+W XPress DR+W Regulatory Information USA Federal Communications Commission FCC NoticeCanada Industry Canada Notice Europe R&TTE Directive 99/5/EC, Wireless Notice Antenna NoticeExposure of Humans to RF Fields Australia & New Zealand Wireless Notice Appendix F Warranty Index