Lantronix XPress DR+ manual Incoming Connection, Response, Active Startup

Page 73

Chapter 9: Setup Mode: Channel Configuration

Connect Mode Option

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

Modem Response Only (Numeric)

 

 

0

0

1

1

1

1

 

 

 

 

 

 

 

 

 

Modem Response Only (Verbose)

 

 

0

0

1

1

1

0

 

 

 

 

 

 

 

 

 

a) Incoming Connection

Never Accept Incoming

Rejects all external connection attempts.

 

 

Accept with DTR Active

Accepts external connection requests only when the DTR input

 

is asserted. Cannot be used with Modem Mode.

Always Accept

Accepts any incoming connection when a connection is not

 

already established. Default setting.

b) Response

Character Response

A single character is transmitted to the serial port when there is a change in connection state:

C = connected, D = disconnected, N = host unreachable.

Single character mode specifies the character response. The IP address of the host connecting to the unit displays when the unit is in verbose mode. This option is overridden when the Active Start Modem Mode or Active Start Host List is in effect. Default setting is Nothing (quiet).

c) Active Startup

No Active Startup

Does not attempt to initiate a connection under any

 

circumstance. Default setting.

 

 

With Any Character

Attempts to connect when any character is received from the

 

serial port.

With DTR Active

Attempts to connect when the DTR input changes from not

 

asserted to asserted.

With a Specific Start

Attempts to connect when it receives a specific start character

Character

from the serial port. The default start character is carriage return.

Manual Connection

Attempts to connect when directed by a command string

 

received from the serial port. The first character of the command

 

string must be a C (ASCII 0x43), and the last character must be

 

either a carriage return (ASCII 0x0D) or a line feed (0x0A). No

 

blanks or space characters may be in the command string.

 

Between the first and last command string characters must be a

 

full or partial destination IP address and may be a destination

 

port number.

 

The IP address must be in standard decimal-dot notation and

 

may be a partial address, representing the least significant 1, 2,

 

or 3 bytes of the remote IP address. The period is required

 

between each pair of IP address numbers.

 

If present, the port number must follow the IP address, must be

 

presented as a decimal number in the range 1-65535, and must

 

be preceded by a forward slash (ASCII 0x2F). The slash

 

separates the IP address and the port number. If you omit the

 

port number from a command string, the internally stored remote

 

port number starts a connection.

XPress DR+ User Guide

73

Image 73
Contents XPress DR+ User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersDate Rev Comments Contents Configuration Using Web Manager Using DeviceInstallerContents Setup Mode Server Configuration Configuration Using Telnet or Serial Port Setup ModeSetup Mode Channel Configuration Expert Settings Option 5 Setup Mode Advanced SettingsMonitor Mode Firmware UpgradesTroubleshooting and Technical Support Appendix D Binary to Hexadecimal Conversions 108Figures Appendix F Warranty 115 Index 116Tables Purpose and Audience Using This GuideSummary of Chapters Chapter DescriptionAdditional Documentation Using This GuideProduct Description IntroductionXPress DR+ Front IntroductionNetwork Protocols Serial Tunneling Industrial Automation ProtocolsExample of Serial Tunneling XPress DR+ Application ExamplesHardware Address Addresses and Port NumbersIP Address Port NumbersLantronix Web Manager. See Configuration Using Web Manager Configuration MethodsPhysically Connecting the XPress DR+ Installation and HardwareWhats in the Box? What Must the User Provide?XPress DR+ Front Panel Installation and HardwareFront of XPress DR+ Serial InterfaceRJ45 Serial Connector Pinouts Screw Terminal Serial ConnectorsSerial Screw Terminal Pinout for RS422 4-Wire Serial Screw Terminal Pinout for RS485 2-WireDTE, 9-Pin XPress DR+ Female Serial RJ45 Pin RS-232 to Serial RJ45 Cable P/NTypical RJ45 Connector Ethernet Interface SignalsEthernet Interface Reset Switch Power RequirementsMulti-Drop Ethernet Connections RXD Activity LED TXD Activity LED Ethernet Link LED LEDsEthernet Activity LED Status Meaning DimensionsXPress DR+ LED Functions Product Information Label Wall Mount BracketApplication Examples XPress DR+WSerial Tunneling Network Serial Tunneling Infrastructure Ad Hoc NetworkXPress DR+W Ad Hoc XPress DR+W Connection Physically Connecting the XPress DR+WFront Panel Description Typical XPress DR+W ConfigurationXPress DR+W LED Functions Required Information for Initial ConfigurationServer Configuration Option Installing the XPress DR+W for Initial ConfigurationWlan Settings IP Address Subnet Mask GatewayBootP/DHCP/AutoIP options Network Mode XPress DR+W onlySet Gateway IP Address Options BitChange Telnet Configuration Password Wlan Configuration OptionNetmask Number of Bits for Host Part Change Dhcp Device NameNetwork Name Ssid TopologyAdhoc Network Channel Hex Key Type Encryption KeyPassphrase WPA Fixed or Automatic Data Rate WPA2/802.11iTransmission Data Rate Next StepsInstalling DeviceInstaller Using DeviceInstallerTo install DeviceInstaller Assigning an IP AddressViewing the Current Configuration Accessing the XPress DR+ Using DeviceInstallerUsing DeviceInstaller To view the units current settingsSetting Description Pins Supports ConfigurableSupports Http Setup Supports Dynamic IPAccessing XPress DR+ Using DeviceInstaller Configuration Using Web ManagerConfiguration Using Web Manager Lantronix Web Manager Network ConfigurationTo assign an IP address automatically Automatic IP Address ConfigurationAutoIP Dhcp Host NameStatic IP Address Configuration Server ConfigurationDefault Gateway To assign an IP address manuallyTo configure the units device server settings Server ConfigurationAdvanced To configure the units host list Host List Configuration0x77FE Server Port MTU Size Serial Settings Channel ConfigurationRetry Settings To configure the channel’s serial settingsChannel Port SettingsFlush Input Buffer Serial to Network Pack ControlFlush Output Buffer Network to Serial To configure a channel’s TCP settings Connection Settings TCPConnect Mode Active Connection Connect Mode Passive ConnectionEndpoint Configuration Connect ProtocolDisconnect Mode Connection Settings UDPTo configure a channel’s UDP settings Common OptionsDatagram Type Datagram ModeDevice Address Table Wlan Configuration XPress DR+W onlyWlan Settings Ad Hoc Network Type To configure the XPress DR+W’s Wlan settingsNetwork Name Ssid Wireless Network ConfigurationNetwork Type ChannelWEP Options Wireless Network SecurityWPA Options Applying Factory Defaults Applying SettingsAdvanced Settings WPA2/802.11i OptionsAccessing Setup Mode Configuration Using Telnet or Serial Port Setup ModeSerial Port Connection Configuration Using Telnet or Serial Port Setup ModeTo establish a Telnet connection To exit setup mode Exiting Setup ModeSetup Mode Server Configuration Setup Mode Server Configuration Dhcp Name Channel 1 Option 1 and Channel 2 Option Setup Mode Channel ConfigurationBaudrate Setup Mode Channel Configuration Interface ModeMode Option Common I/F Mode Setting Binary HexPort Number FlowFlow Control Option Hex Port Numbers Reserved forConnect Mode Option Connect ModeResponse Incoming ConnectionActive Startup Connection Autostart AutomaticHostlist To enable the hostlist Modem ModeDatagram Type Directed UDPMessage Meaning Modem Mode Commands Modem Mode Function CommandAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeRemote IP Address Disconnect Mode Options Disconnect Mode OptionRemote Port DisConnModePack Control Flush Mode Buffer FlushingOption Packing Interval DisConnTime Inactivity TimeoutTrailing Characters Send CharactersWlan Settings XPress DR+W Only Channel Port PasswordSend Characters Telnet Terminal TypeTopology 0=Infrastructure, 1=Adhoc 0 ? WEP WEP64 or 13 WEP128 bytes and limits the number of key TX Data rate 0=fixed, 1=auto fallback 1 ? Enable Power Management Expert Settings Option Setup Mode Advanced SettingsARP Cache timeout in seconds Disable Monitor Mode at bootupEnable alternate MAC Security Settings OptionSetup Mode Advanced Settings Http Port NumberDisable Telnet Setup Disable SnmpDisable Tftp Firmware Upgrade Disable Port 77FE HexDefault Settings Option Security Settings Expert SettingsWlan Settings XPress DR+W only Topology AdHoc Network NameUsing Tftp Graphical User Interface Firmware UpgradesObtaining Firmware Reloading Firmware ROM FileFirmware Upgrades Using Tftp Command Line InterfaceTo recover firmware Firmware Upgrades Entering Monitor Mode Using the Serial Port Monitor ModeEntering Monitor Mode Using the Network Port Monitor Mode CommandsCommand Command Name Function Monitor ModeMonitor Mode Commands G0, G1, ....,Ge, GfResponse Meaning Command Response CodesProblems and Error Messages Troubleshooting and Technical SupportProblem/Message Reason Solution Problems and Error MessagesTroubleshooting and Technical Support XPress DR+ User Guide 101 Technical Support Europe, Middle East, and Africa Technical SupportXPress DR+ and XPress DR+W Specifications Appendix a Technical SpecificationsXPress DR+W Wireless Specifications Appendix a Technical SpecificationsCategory Ieee 802.11b/g Lantronix P/N Description Appendix B Lantronix Cables and AdaptersApplications AutoIP Appendix C Alternative Methods of Assigning an IP AddressAppendix C Alternative Methods of Assigning an IP Address ARP and TelnetTo assign a temporary IP address Converting Binary to Hexadecimal Appendix D Binary to Hexadecimal ConversionsConversion Table Scientific CalculatorAppendix D Binary to Hexadecimal Conversions Declaration of Conformity Appendix E Compliance InformationElectromagnetic Emissions and Immunity XPress DR+ Emissions ImmunityRadio Appendix E Compliance InformationElectromagnetic Emissions and Immunity XPress DR+W USA Federal Communications Commission FCC Notice XPress DR+W Regulatory InformationCanada Industry Canada Notice Antenna Notice Europe R&TTE Directive 99/5/EC, Wireless NoticeExposure of Humans to RF Fields Australia & New Zealand Wireless Notice Appendix F Warranty Index