Chapter 9: Setup Mode: Channel Configuration

Send Characters

Enter up to two characters in hexadecimal representation in sendchar.

SendChar 1 ( 0) ? _

SendChar 2 ( 0) ? _

If the unit receives a character on the serial line that matches one of these characters, it sends the character immediately, along with any awaiting characters, to the TCP connection. This action minimizes the response time for specific protocol characters on the serial line (for example, ETX, EOT). Setting the first sendchar to 00 disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control on page 80).

Telnet Terminal Type

This parameter displays only if you enabled the terminal type option in Disconnect Mode. With this option enabled, you can use the terminal name for the Telnet terminal type. Enter only one name.

With terminal type option enabled, the unit also reacts to the EOR (end of record) and binary options, useful for applications like terminal emulation to IBM hosts.

Channel (Port) Password

This parameter appears only if the channel (port) password option is enabled in Disconnect Mode. With this option enabled, you can set a password on the serial port.

WLAN Settings (XPress DR+W Only)

Note: To use DeviceInstaller for communication to an XPress DR+W over a wireless network, you must first configure the network and WLAN settings using a serial connection. See Chapter 4:XPress DR+W.

Before the XPress DR+W can communicate on an 802.11b/g wireless network, the WLAN settings must match the wireless network. By default, the XPress DR+W is set to Ad Hoc network mode, and its wireless Network Name (SSID) is LTRX_IBSS.

Note: Due to regulations, the country-specific setting has been removed from the setup menu and Web Manager. We provide a separate utility for changing the Country/Zone setting. The utility is called SetZone and is included in the XPress DR+W package. It is also available for download from the Lantronix web site (www.lantronix.com).

The syntax is SetZone <IP address> [<zone abbreviation>]

Leaving the zone blank causes the utility to report the current setting only.

Following are valid zone abbreviations. These settings are consistent with

IEEE802.11b/g zones:

XPress DR+ User Guide

82

Image 82
Contents XPress DR+ User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersDate Rev Comments Contents Configuration Using Web Manager Using DeviceInstallerContents Setup Mode Server Configuration Configuration Using Telnet or Serial Port Setup ModeSetup Mode Channel Configuration Setup Mode Advanced Settings Expert Settings Option 5Troubleshooting and Technical Support Firmware UpgradesMonitor Mode Appendix D Binary to Hexadecimal Conversions 108Appendix F Warranty 115 Index 116 FiguresTables Summary of Chapters Using This GuidePurpose and Audience Chapter DescriptionUsing This Guide Additional DocumentationIntroduction Product DescriptionIntroduction XPress DR+ FrontIndustrial Automation Protocols Network Protocols Serial TunnelingXPress DR+ Application Examples Example of Serial TunnelingIP Address Addresses and Port NumbersHardware Address Port NumbersConfiguration Methods Lantronix Web Manager. See Configuration Using Web ManagerWhats in the Box? Installation and HardwarePhysically Connecting the XPress DR+ What Must the User Provide?Installation and Hardware XPress DR+ Front PanelSerial Interface Front of XPress DR+Serial Screw Terminal Pinout for RS422 4-Wire Screw Terminal Serial ConnectorsRJ45 Serial Connector Pinouts Serial Screw Terminal Pinout for RS485 2-WirePin RS-232 to Serial RJ45 Cable P/N DTE, 9-Pin XPress DR+ Female Serial RJ45Typical RJ45 Connector Ethernet Interface SignalsEthernet Interface Reset Switch Power RequirementsMulti-Drop Ethernet Connections RXD Activity LED TXD Activity LED Ethernet Link LED LEDsEthernet Activity LED Status Meaning DimensionsXPress DR+ LED Functions Wall Mount Bracket Product Information LabelApplication Examples XPress DR+WSerial Tunneling Network Serial Tunneling Infrastructure Ad Hoc NetworkXPress DR+W Physically Connecting the XPress DR+W Ad Hoc XPress DR+W ConnectionTypical XPress DR+W Configuration Front Panel DescriptionRequired Information for Initial Configuration XPress DR+W LED FunctionsWlan Settings Installing the XPress DR+W for Initial ConfigurationServer Configuration Option IP Address Subnet Mask GatewaySet Gateway IP Address Network Mode XPress DR+W onlyBootP/DHCP/AutoIP options Options BitNetmask Number of Bits for Host Part Wlan Configuration OptionChange Telnet Configuration Password Change Dhcp Device NameNetwork Name Ssid TopologyAdhoc Network Channel Hex Key Type Encryption KeyPassphrase WPA WPA2/802.11i Fixed or Automatic Data RateNext Steps Transmission Data RateTo install DeviceInstaller Using DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressUsing DeviceInstaller Accessing the XPress DR+ Using DeviceInstallerViewing the Current Configuration To view the units current settingsSetting Description Supports Http Setup Supports ConfigurablePins Supports Dynamic IPAccessing XPress DR+ Using DeviceInstaller Configuration Using Web ManagerConfiguration Using Web Manager Network Configuration Lantronix Web ManagerAutoIP Automatic IP Address ConfigurationTo assign an IP address automatically Dhcp Host NameDefault Gateway Server ConfigurationStatic IP Address Configuration To assign an IP address manuallyTo configure the units device server settings Server ConfigurationAdvanced To configure the units host list Host List Configuration0x77FE Server Port MTU Size Retry Settings Channel ConfigurationSerial Settings To configure the channel’s serial settingsPort Settings ChannelFlush Input Buffer Serial to Network Pack ControlFlush Output Buffer Network to Serial Connection Settings TCP To configure a channel’s TCP settingsEndpoint Configuration Connect Mode Passive ConnectionConnect Mode Active Connection Connect ProtocolTo configure a channel’s UDP settings Connection Settings UDPDisconnect Mode Common OptionsDatagram Mode Datagram TypeWlan Configuration XPress DR+W only Device Address TableTo configure the XPress DR+W’s Wlan settings Wlan Settings Ad Hoc Network TypeNetwork Type Wireless Network ConfigurationNetwork Name Ssid ChannelWEP Options Wireless Network SecurityWPA Options Advanced Settings Applying SettingsApplying Factory Defaults WPA2/802.11i OptionsConfiguration Using Telnet or Serial Port Setup Mode Accessing Setup ModeSerial Port Connection Configuration Using Telnet or Serial Port Setup ModeTo establish a Telnet connection Exiting Setup Mode To exit setup modeSetup Mode Server Configuration Setup Mode Server Configuration Dhcp Name Channel 1 Option 1 and Channel 2 Option Setup Mode Channel ConfigurationBaudrate Mode Option Interface ModeSetup Mode Channel Configuration Common I/F Mode Setting Binary HexFlow Control Option Hex FlowPort Number Port Numbers Reserved forConnect Mode Connect Mode OptionResponse Incoming ConnectionActive Startup Connection Autostart AutomaticHostlist Datagram Type Modem ModeTo enable the hostlist Directed UDPMessage Meaning Modem Mode Function Command Modem Mode CommandsAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeRemote IP Address Remote Port Disconnect Mode OptionDisconnect Mode Options DisConnModePack Control Flush Mode Buffer FlushingOption Trailing Characters DisConnTime Inactivity TimeoutPacking Interval Send CharactersSend Characters Channel Port PasswordWlan Settings XPress DR+W Only Telnet Terminal TypeTopology 0=Infrastructure, 1=Adhoc 0 ? WEP WEP64 or 13 WEP128 bytes and limits the number of key TX Data rate 0=fixed, 1=auto fallback 1 ? Enable Power Management ARP Cache timeout in seconds Setup Mode Advanced SettingsExpert Settings Option Disable Monitor Mode at bootupSetup Mode Advanced Settings Security Settings OptionEnable alternate MAC Http Port NumberDisable Tftp Firmware Upgrade Disable SnmpDisable Telnet Setup Disable Port 77FE HexDefault Settings Option Wlan Settings XPress DR+W only Expert SettingsSecurity Settings Topology AdHoc Network NameObtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface ROM FileFirmware Upgrades Using Tftp Command Line InterfaceTo recover firmware Firmware Upgrades Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsMonitor Mode Commands Monitor ModeCommand Command Name Function G0, G1, ....,Ge, GfCommand Response Codes Response MeaningProblem/Message Reason Solution Troubleshooting and Technical SupportProblems and Error Messages Problems and Error MessagesTroubleshooting and Technical Support XPress DR+ User Guide 101 Technical Support Technical Support Europe, Middle East, and AfricaAppendix a Technical Specifications XPress DR+ and XPress DR+W SpecificationsXPress DR+W Wireless Specifications Appendix a Technical SpecificationsCategory Ieee 802.11b/g Lantronix P/N Description Appendix B Lantronix Cables and AdaptersApplications Appendix C Alternative Methods of Assigning an IP Address AutoIPAppendix C Alternative Methods of Assigning an IP Address ARP and TelnetTo assign a temporary IP address Conversion Table Appendix D Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorAppendix D Binary to Hexadecimal Conversions Electromagnetic Emissions and Immunity XPress DR+ Appendix E Compliance InformationDeclaration of Conformity Emissions ImmunityRadio Appendix E Compliance InformationElectromagnetic Emissions and Immunity XPress DR+W USA Federal Communications Commission FCC Notice XPress DR+W Regulatory InformationCanada Industry Canada Notice Antenna Notice Europe R&TTE Directive 99/5/EC, Wireless NoticeExposure of Humans to RF Fields Australia & New Zealand Wireless Notice Appendix F Warranty Index