Lantronix Ethernet manual Installing and Configuring the WiBox, Quick Start, Case-sensitive

Page 20

Quick Start

WLAN SSID:

________________ (case-sensitive)

WEP Enabled Y/N?

_______

WEP Key 64 bit or 128 bit? _______

WEP Key:

____________________________

(Entered in HEX format (0-9 A-F) xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx)

or

 

WPA Enabled Y/N:

____________________________

WPA Key Type hex or passphrase? _______

WPA Key:

____________________________

Installing and Configuring the WiBox

Complete the following steps to connect and initially configure the WiBox. Initial configuration is done using the Setup Mode’s Change Setup menu.

Figure 3-1. WiBox Connected for Configuration

1.Connect one end of the supplied DB9F – DB9F null modem serial cable to the WiBox’s serial port 1.

2.Connect the other end of the DB9 serial cable to a terminal or a PC’s serial COM port.

3.On the PC, open a terminal emulation application (e.g. HyperTerminal). The default serial settings are 9600 baud, 8 bits, not parity, 1 stop bit, and no flow control (9600, 8, N, 1).

4.Enter Setup Mode by simultaneously connecting the power supply and holding down the x key. Upon connection, the following information displays:

MAC address 00204A8178A4

Software version V6.1.0.2 (040519)

Press Enter for Setup Mode

5. Press Enter within 5 seconds to display the Change Setup menu.

WiBox2100E User Guide

20

Image 20
Contents WiBox2100E User Guide Lantronix Corporate Headquarters Technical Support Sales OfficesContents Setup Mode Server Configuration ContentsSetup Mode Advanced Settings List of Tables ComplianceList of Figures Serial Tunneling Infrastructure Network ExampleChapter Summary Using This GuidePurpose and Audience Using This Guide Additional DocumentationName Model Part Numbers IntroductionApplications Introduction Application ExamplesSerial Tunneling Network Ad Hoc Network Serial Tunneling InfrastructureConfiguration Methods Protocol SupportAd Hoc WiBox Connection WiBox with EthernetWlan Settings Addresses and Port NumbersHardware Address IP AddressSerial Connector Pinouts DB9M DTE Serial ConnectorRS-485 2-Wire Pinouts WBX2100E Network InterfaceWiBox LEDs Ethernet Connector PinoutsLEDs Technical Specifications Quick Start Required InformationHardware Address 00-20-4a IP Address Subnet Mask GatewayInstalling and Configuring the WiBox WEP Enabled Y/N? WEP Key 64 bit or 128 bit?WPA Enabled Y/N WPA Key Type hex or passphrase? Quick StartSyntax is SetZone IP address zone abbreviation WEP Using Device Installer To install the DeviceInstallerViewing the Current Configuration To view the WiBox’s configuration settingsFirmware Upgradeable Rate Supports Wired EthernetWebPort Maximum Baud RateQuick Start Web-Manager Configuration Accessing Web-Manager through a Web BrowserNetwork Configuration Web-Manager ConfigurationAutomatic IP Address Configuration Select Obtain IP address automaticallyAuto-IP Dhcp Host NameServer Configuration Static IP Address ConfigurationEthernet Configuration Select Use the following IP configurationAdvanced To configure the WiBox’s device server settingsServer Configuration Hostlist Configuration To configure the WiBox’s hostlistCPU Performance Mode Http Server PortChannel 1 and Channel 2 Configuration Serial SettingsRetry Settings Host InformationPort Settings Disable Serial PortChannel ProtocolPack Control Flush Input Buffer Serial to NetworkConnection Settings TCP Flush Output Buffer Network to SerialConnect Protocol At Time of DisconnectConnect Mode Passive Connection Connect Mode Active ConnectionEndpoint Configuration Common OptionsConnection Settings UDP Disconnect ModeDatagram Mode Datagram TypeDevice Address Table Wlan ConfigurationTo configure the WiBox’s Wlan settings Wireless Network Configuration Wireless Network SecurityNetwork Name Network Type Select Infrastructure or Ad Hoc ChannelWPA Options Advanced SettingsWEP Options Updating Settings Applying DefaultsTelnet or Serial Port Setup Mode Configuration Accessing Setup ModeTelnet Connection To establish a Telnet connectionExiting Setup Mode Telnet or Serial Port Setup Mode ConfigurationTo exit Setup Mode Serial Port ConnectionSetup Mode Server Configuration Server Configuration OptionNetwork Mode IP AddressChange Telnet Configuration Password Setup Mode Server ConfigurationSet Gateway IP Address Netmask Number of Bits for Host PartDhcp Name Baudrate Setup Mode Channel ConfigurationChannel 1 Option Interface Mode Setup Mode Channel ConfigurationMode Option Common I/F Mode Setting Binary HexConnect Mode Port NumberFlow Control Option Hex Port Numbers Reserved forConnect Mode Option Connect Mode OptionsIncoming Connection ResponseActive Startup Incoming ConnectionResponse Manual Connection Manual Connection Address ExampleTo enable the hostlist Autostart AutomaticConnection HostlistModem Mode Datagram Type11. Modem Mode Messages Message MeaningFull Verbose Numeric ResponseSend the Escape Sequence +++ in Modem Mode Modem Mode Function CommandModem Mode Commands Auto Increment Source PortDisconnect Mode Option Disconnect Mode OptionsRemote IP Address Remote PortFlush Mode Buffer Flushing Pack ControlDisConnTime Inactivity Timeout Packing IntervalTrailing Characters Send CharactersChannel Port Password Wlan SettingsSend Characters Telnet Terminal TypeSecurity Network Name SsidAdhoc Network Channel Fixed or Automatic Data Rate Transmission Data RateEnable Power Management TCP Keepalive time in seconds Setup Mode Advanced SettingsExpert Settings Option ARP Cache timeout in seconds Disable Monitor Mode at bootupCPU Performance Http Port NumberSecurity Settings Disable Port 77FE Hex Disable Web ServerDisable Web Setup Disable Echo PortsGenerally, one of two situations applies Channel 2 Configuration Default SettingsChannel 1 Configuration Expert Settings Security SettingsEnable Power Management Channel SecurityExit Configuration Mode Monitor Mode Entering Monitor Mode via the Serial PortEntering Monitor Mode via the Network Port Monitor Mode CommandsMonitor Mode Command Response CodesResponse Meaning G0, G1, ....,Ge, GfUsing Tftp Graphical User Interface Updating FirmwareObtaining Firmware Reloading Firmware ROM FileNetwork Upgrade Using Tftp Command Line InterfaceUpdating Firmware To download new firmware from a computerWlan Country Setting Syntax is SetZone IP address zone abbreviationMethod Wireless BridgingConfiguring the WiBox in Bridging Mode Troubleshooting Troubleshooting Diagnostic LED StatesProblems and Error Messages Problem/Message Reason SolutionLater, there is only one setting for WiBox2100E only Caps Lock is not onTechnical Support Technical Support Europe, Middle East, and AfricaBinary to Hexadecimal Conversions Converting Binary to HexadecimalConversion Table Scientific CalculatorBinary to Hexadecimal Conversions Compliance Compliance InformationRegulatory Information USA Federal Communications Commission FCC NoticeCanada Industry Canada Notice ComplianceEurope R&TTE Directive 99/5/EC, Wireless Notice Australia & New Zealand Wireless NoticeAntenna Notice Exposure of Humans to RF FieldsCompliance Warranty

Ethernet specifications

Lantronix Ethernet technology is a pivotal component in modern networking, facilitating seamless communication and connectivity across a multitude of devices. Renowned for its reliability and innovation, Lantronix offers a diverse range of products and solutions that cater to various industries, from healthcare to industrial automation.

One of the standout features of Lantronix Ethernet devices is their ability to enable remote access and management of equipment. This is particularly beneficial in scenarios where physical access is limited or impractical. With secure remote management, organizations can monitor, control, and configure devices from virtually anywhere, streamlining operations and reducing downtime.

Lantronix Ethernet products utilize advanced technologies such as Serial to Ethernet conversion, which allows legacy serial devices to communicate over an IP network. This feature is essential for companies looking to modernize their infrastructure without the need for a complete overhaul of existing equipment. By bridging the gap between old and new technologies, Lantronix ensures that organizations can extend the lifespan of their investments.

Another key characteristic of Lantronix Ethernet solutions is their robustness and security. Designed to withstand various environmental conditions, these devices are suitable for deployment in harsh environments, making them ideal for industrial applications. Additionally, robust encryption protocols and security features help safeguard sensitive data, ensuring that only authorized personnel can access the system.

Scalability is also a significant advantage of Lantronix Ethernet technology. As businesses grow and evolve, their networking needs often change. Lantronix products are designed to scale easily, allowing organizations to add new devices and functionality without disrupting existing operations. This flexibility enables businesses to adapt to new challenges and opportunities as they arise.

Moreover, Lantronix places a strong emphasis on ease of integration. With extensive support for various communication protocols and interfaces, their Ethernet solutions can be quickly and effectively integrated into existing systems, minimizing deployment time and maximizing efficiency.

In conclusion, Lantronix Ethernet technology represents a comprehensive solution for modern networking needs. With features such as remote management, serial communication capabilities, security, scalability, and ease of integration, Lantronix stands out as a leader in the connectivity landscape, empowering businesses to optimize operations and enhance productivity. Whether in industrial environments or remote locations, Lantronix Ethernet solutions deliver the reliability and performance required in today’s fast-paced digital world.