Lantronix Ethernet manual Network Upgrade, Using Tftp Command Line Interface, Updating Firmware

Page 78

Updating Firmware

Figure 10-1. TFTP Window

After the firmware has been loaded and stored, which takes approximately 8 seconds, the unit performs a power reset.

Using TFTP: Command Line Interface

To download new firmware from a computer:

1.Enter the following from a TFTP command line interface:

tftp –i <ip address> put <local filename> <destination file name>

The following examples demonstrate the TFTP command sequence to download the .rom file and the .cob file:

tftp –i 192.168.1.111 put wbxg_6102.rom W7

tftp –i 192.168.1.111 put wbx_webm_1403.cob WEB1

2.In the Remote file name field, enter the current internal operational code or WEB1 for the internal Web interface.

Network Upgrade

Use the command: tftp –i <ip address> put <wbx rom filename> W7 or

the Device Installer upgrade feature. DI 4.0.0.4 and later support the W7 destination file.

Recovering the Firmware Using the Serial Port and DeviceInstaller

If for some reason the firmware is damaged, you can recover the firmware file by using DeviceInstaller to download the *.ROM file over the serial port.

To recover firmware:

1.Connect the COM interface of your PC to serial port 1 of the WiBox.

2.Start DeviceInstaller. If your PC has more than one network adapter, a message displays. Select an adapter and click the OK button.

WiBox2100E User Guide

78

Image 78
Contents WiBox2100E User Guide Lantronix Corporate Headquarters Technical Support Sales OfficesContents Setup Mode Server Configuration ContentsSetup Mode Advanced Settings List of Tables ComplianceList of Figures Serial Tunneling Infrastructure Network ExampleUsing This Guide Purpose and AudienceChapter Summary Using This Guide Additional DocumentationIntroduction ApplicationsName Model Part Numbers Application Examples Serial Tunneling NetworkIntroduction Ad Hoc Network Serial Tunneling InfrastructureAd Hoc WiBox Connection Configuration MethodsProtocol Support WiBox with EthernetHardware Address Wlan SettingsAddresses and Port Numbers IP AddressSerial Connector Pinouts DB9M DTE Serial ConnectorRS-485 2-Wire Pinouts WBX2100E Network InterfaceEthernet Connector Pinouts LEDsWiBox LEDs Technical Specifications Hardware Address 00-20-4a Quick StartRequired Information IP Address Subnet Mask GatewayWPA Enabled Y/N WPA Key Type hex or passphrase? Installing and Configuring the WiBoxWEP Enabled Y/N? WEP Key 64 bit or 128 bit? Quick StartSyntax is SetZone IP address zone abbreviation WEP Using Device Installer To install the DeviceInstallerViewing the Current Configuration To view the WiBox’s configuration settingsWebPort Firmware UpgradeableRate Supports Wired Ethernet Maximum Baud RateQuick Start Web-Manager Configuration Accessing Web-Manager through a Web BrowserNetwork Configuration Web-Manager ConfigurationAuto-IP Automatic IP Address ConfigurationSelect Obtain IP address automatically Dhcp Host NameEthernet Configuration Server ConfigurationStatic IP Address Configuration Select Use the following IP configurationTo configure the WiBox’s device server settings Server ConfigurationAdvanced CPU Performance Mode Hostlist ConfigurationTo configure the WiBox’s hostlist Http Server PortRetry Settings Channel 1 and Channel 2 ConfigurationSerial Settings Host InformationChannel Port SettingsDisable Serial Port ProtocolPack Control Flush Input Buffer Serial to NetworkConnect Protocol Connection Settings TCPFlush Output Buffer Network to Serial At Time of DisconnectConnect Mode Passive Connection Connect Mode Active ConnectionEndpoint Configuration Common OptionsConnection Settings UDP Disconnect ModeDatagram Mode Datagram TypeWlan Configuration To configure the WiBox’s Wlan settingsDevice Address Table Network Name Wireless Network ConfigurationWireless Network Security Network Type Select Infrastructure or Ad Hoc ChannelAdvanced Settings WEP OptionsWPA Options Updating Settings Applying DefaultsTelnet Connection Telnet or Serial Port Setup Mode ConfigurationAccessing Setup Mode To establish a Telnet connectionTo exit Setup Mode Exiting Setup ModeTelnet or Serial Port Setup Mode Configuration Serial Port ConnectionNetwork Mode Setup Mode Server ConfigurationServer Configuration Option IP AddressSet Gateway IP Address Change Telnet Configuration PasswordSetup Mode Server Configuration Netmask Number of Bits for Host PartDhcp Name Setup Mode Channel Configuration Channel 1 OptionBaudrate Mode Option Interface ModeSetup Mode Channel Configuration Common I/F Mode Setting Binary HexFlow Control Option Hex Connect ModePort Number Port Numbers Reserved forIncoming Connection Connect Mode OptionConnect Mode Options ResponseIncoming Connection ResponseActive Startup Manual Connection Manual Connection Address ExampleConnection To enable the hostlistAutostart Automatic HostlistModem Mode Datagram TypeFull Verbose 11. Modem Mode MessagesMessage Meaning Numeric ResponseModem Mode Commands Send the Escape Sequence +++ in Modem ModeModem Mode Function Command Auto Increment Source PortRemote IP Address Disconnect Mode OptionDisconnect Mode Options Remote PortFlush Mode Buffer Flushing Pack ControlTrailing Characters DisConnTime Inactivity TimeoutPacking Interval Send CharactersSend Characters Channel Port PasswordWlan Settings Telnet Terminal TypeNetwork Name Ssid Adhoc Network ChannelSecurity Fixed or Automatic Data Rate Transmission Data RateEnable Power Management Setup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds CPU Performance ARP Cache timeout in secondsDisable Monitor Mode at bootup Http Port NumberSecurity Settings Disable Web Setup Disable Port 77FE HexDisable Web Server Disable Echo PortsGenerally, one of two situations applies Default Settings Channel 1 ConfigurationChannel 2 Configuration Enable Power Management Expert SettingsSecurity Settings Channel SecurityExit Configuration Mode Entering Monitor Mode via the Network Port Monitor ModeEntering Monitor Mode via the Serial Port Monitor Mode CommandsResponse Meaning Monitor ModeCommand Response Codes G0, G1, ....,Ge, GfObtaining Firmware Reloading Firmware Using Tftp Graphical User InterfaceUpdating Firmware ROM FileUpdating Firmware Network UpgradeUsing Tftp Command Line Interface To download new firmware from a computerWlan Country Setting Syntax is SetZone IP address zone abbreviationWireless Bridging Configuring the WiBox in Bridging ModeMethod Troubleshooting Problems and Error Messages TroubleshootingDiagnostic LED States Problem/Message Reason SolutionLater, there is only one setting for WiBox2100E only Caps Lock is not onTechnical Support Technical Support Europe, Middle East, and AfricaConversion Table Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorBinary to Hexadecimal Conversions Compliance Compliance InformationCanada Industry Canada Notice Regulatory InformationUSA Federal Communications Commission FCC Notice ComplianceAntenna Notice Europe R&TTE Directive 99/5/EC, Wireless NoticeAustralia & New Zealand Wireless Notice Exposure of Humans to RF FieldsCompliance Warranty

Ethernet specifications

Lantronix Ethernet technology is a pivotal component in modern networking, facilitating seamless communication and connectivity across a multitude of devices. Renowned for its reliability and innovation, Lantronix offers a diverse range of products and solutions that cater to various industries, from healthcare to industrial automation.

One of the standout features of Lantronix Ethernet devices is their ability to enable remote access and management of equipment. This is particularly beneficial in scenarios where physical access is limited or impractical. With secure remote management, organizations can monitor, control, and configure devices from virtually anywhere, streamlining operations and reducing downtime.

Lantronix Ethernet products utilize advanced technologies such as Serial to Ethernet conversion, which allows legacy serial devices to communicate over an IP network. This feature is essential for companies looking to modernize their infrastructure without the need for a complete overhaul of existing equipment. By bridging the gap between old and new technologies, Lantronix ensures that organizations can extend the lifespan of their investments.

Another key characteristic of Lantronix Ethernet solutions is their robustness and security. Designed to withstand various environmental conditions, these devices are suitable for deployment in harsh environments, making them ideal for industrial applications. Additionally, robust encryption protocols and security features help safeguard sensitive data, ensuring that only authorized personnel can access the system.

Scalability is also a significant advantage of Lantronix Ethernet technology. As businesses grow and evolve, their networking needs often change. Lantronix products are designed to scale easily, allowing organizations to add new devices and functionality without disrupting existing operations. This flexibility enables businesses to adapt to new challenges and opportunities as they arise.

Moreover, Lantronix places a strong emphasis on ease of integration. With extensive support for various communication protocols and interfaces, their Ethernet solutions can be quickly and effectively integrated into existing systems, minimizing deployment time and maximizing efficiency.

In conclusion, Lantronix Ethernet technology represents a comprehensive solution for modern networking needs. With features such as remote management, serial communication capabilities, security, scalability, and ease of integration, Lantronix stands out as a leader in the connectivity landscape, empowering businesses to optimize operations and enhance productivity. Whether in industrial environments or remote locations, Lantronix Ethernet solutions deliver the reliability and performance required in today’s fast-paced digital world.