Manual Connection

Attempts to connect when directed by a command string received from the serial port. The first character of the command string must be a C (ASCII 0x43), and the last character must be either a carriage return (ASCII 0x0D) or a line feed (0x0A). No blanks or space characters may be in the command string. Between the first and last command string characters must be a full or partial destination IP address and may be a destination port number.

The IP address must be in standard decimal-dot notation and may be a partial address, representing the least significant 1, 2, or 3 bytes of the remote IP address. The period is required between each pair of IP address numbers.

If present, the port number must follow the IP address, must be presented as a decimal number in the range 1-65535, and must be preceded by a forward slash (ASCII 0x2F). The slash separates the IP address and the port number. If you omit the port number from a command string, the internally stored remote port number starts a connection.

If a partial IP address is presented in a command string, it is interpreted to be the least significant bytes of the IP address and uses the internally stored remote IP address to provide the most significant bytes of the IP address. If the IP address entered is 0.0.0.0/0, the device server enters Monitor Mode.

For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23.

Figure 7-2. Manual Connection Address Example

 

Command String

 

Result if remote IP is 129.1.2.3 and remote port is 1234

 

 

 

 

 

C121.2.4.5/1

 

Complete override; connection is started with host 121.2.4.5,

 

 

port 1.

 

 

 

 

 

 

 

 

C5

 

Connects to 129.1.2.5, port 1234.

 

 

 

 

 

C28.10/12

 

Connects to 129.1.28.10, port 12.

 

 

 

 

 

C0.0.0.0/0

 

Enters Monitor Mode.

 

 

 

 

WiBox2100E User Guide

55

Image 55
Contents WiBox2100E User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersContents Contents Setup Mode Server ConfigurationSetup Mode Advanced Settings Compliance List of TablesSerial Tunneling Infrastructure Network Example List of FiguresPurpose and Audience Using This GuideChapter Summary Additional Documentation Using This GuideApplications IntroductionName Model Part Numbers Serial Tunneling Network Application ExamplesIntroduction Serial Tunneling Infrastructure Ad Hoc NetworkWiBox with Ethernet Configuration MethodsProtocol Support Ad Hoc WiBox ConnectionIP Address Wlan SettingsAddresses and Port Numbers Hardware AddressDB9M DTE Serial Connector Serial Connector PinoutsWBX2100E Network Interface RS-485 2-Wire PinoutsLEDs Ethernet Connector PinoutsWiBox LEDs Technical Specifications IP Address Subnet Mask Gateway Quick StartRequired Information Hardware Address 00-20-4aQuick Start Installing and Configuring the WiBoxWEP Enabled Y/N? WEP Key 64 bit or 128 bit? WPA Enabled Y/N WPA Key Type hex or passphrase?Syntax is SetZone IP address zone abbreviation WEP To install the DeviceInstaller Using Device InstallerTo view the WiBox’s configuration settings Viewing the Current ConfigurationMaximum Baud Rate Firmware UpgradeableRate Supports Wired Ethernet WebPortQuick Start Accessing Web-Manager through a Web Browser Web-Manager ConfigurationWeb-Manager Configuration Network ConfigurationDhcp Host Name Automatic IP Address ConfigurationSelect Obtain IP address automatically Auto-IPSelect Use the following IP configuration Server ConfigurationStatic IP Address Configuration Ethernet ConfigurationServer Configuration To configure the WiBox’s device server settingsAdvanced Http Server Port Hostlist ConfigurationTo configure the WiBox’s hostlist CPU Performance ModeHost Information Channel 1 and Channel 2 ConfigurationSerial Settings Retry SettingsProtocol Port SettingsDisable Serial Port ChannelFlush Input Buffer Serial to Network Pack ControlAt Time of Disconnect Connection Settings TCPFlush Output Buffer Network to Serial Connect ProtocolConnect Mode Active Connection Connect Mode Passive ConnectionCommon Options Endpoint ConfigurationDisconnect Mode Connection Settings UDPDatagram Type Datagram ModeTo configure the WiBox’s Wlan settings Wlan ConfigurationDevice Address Table Network Type Select Infrastructure or Ad Hoc Channel Wireless Network ConfigurationWireless Network Security Network NameWEP Options Advanced SettingsWPA Options Applying Defaults Updating SettingsTo establish a Telnet connection Telnet or Serial Port Setup Mode ConfigurationAccessing Setup Mode Telnet ConnectionSerial Port Connection Exiting Setup ModeTelnet or Serial Port Setup Mode Configuration To exit Setup ModeIP Address Setup Mode Server ConfigurationServer Configuration Option Network ModeNetmask Number of Bits for Host Part Change Telnet Configuration PasswordSetup Mode Server Configuration Set Gateway IP AddressDhcp Name Channel 1 Option Setup Mode Channel ConfigurationBaudrate Common I/F Mode Setting Binary Hex Interface ModeSetup Mode Channel Configuration Mode OptionPort Numbers Reserved for Connect ModePort Number Flow Control Option HexResponse Connect Mode OptionConnect Mode Options Incoming ConnectionResponse Incoming ConnectionActive Startup Manual Connection Address Example Manual ConnectionHostlist To enable the hostlistAutostart Automatic ConnectionDatagram Type Modem ModeNumeric Response 11. Modem Mode MessagesMessage Meaning Full VerboseAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeModem Mode Function Command Modem Mode CommandsRemote Port Disconnect Mode OptionDisconnect Mode Options Remote IP AddressPack Control Flush Mode Buffer FlushingSend Characters DisConnTime Inactivity TimeoutPacking Interval Trailing CharactersTelnet Terminal Type Channel Port PasswordWlan Settings Send CharactersAdhoc Network Channel Network Name SsidSecurity Transmission Data Rate Fixed or Automatic Data RateEnable Power Management Expert Settings Option Setup Mode Advanced SettingsTCP Keepalive time in seconds Http Port Number ARP Cache timeout in secondsDisable Monitor Mode at bootup CPU PerformanceSecurity Settings Disable Echo Ports Disable Port 77FE HexDisable Web Server Disable Web SetupGenerally, one of two situations applies Channel 1 Configuration Default SettingsChannel 2 Configuration Channel Security Expert SettingsSecurity Settings Enable Power ManagementExit Configuration Mode Monitor Mode Commands Monitor ModeEntering Monitor Mode via the Serial Port Entering Monitor Mode via the Network PortG0, G1, ....,Ge, Gf Monitor ModeCommand Response Codes Response MeaningROM File Using Tftp Graphical User InterfaceUpdating Firmware Obtaining Firmware Reloading FirmwareTo download new firmware from a computer Network UpgradeUsing Tftp Command Line Interface Updating FirmwareSyntax is SetZone IP address zone abbreviation Wlan Country SettingConfiguring the WiBox in Bridging Mode Wireless BridgingMethod Troubleshooting Problem/Message Reason Solution TroubleshootingDiagnostic LED States Problems and Error MessagesLater, there is only one setting for Caps Lock is not on WiBox2100E onlyTechnical Support Europe, Middle East, and Africa Technical SupportScientific Calculator Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableBinary to Hexadecimal Conversions Compliance Information ComplianceCompliance Regulatory InformationUSA Federal Communications Commission FCC Notice Canada Industry Canada NoticeExposure of Humans to RF Fields Europe R&TTE Directive 99/5/EC, Wireless NoticeAustralia & New Zealand Wireless Notice Antenna NoticeCompliance Warranty

Ethernet specifications

Lantronix Ethernet technology is a pivotal component in modern networking, facilitating seamless communication and connectivity across a multitude of devices. Renowned for its reliability and innovation, Lantronix offers a diverse range of products and solutions that cater to various industries, from healthcare to industrial automation.

One of the standout features of Lantronix Ethernet devices is their ability to enable remote access and management of equipment. This is particularly beneficial in scenarios where physical access is limited or impractical. With secure remote management, organizations can monitor, control, and configure devices from virtually anywhere, streamlining operations and reducing downtime.

Lantronix Ethernet products utilize advanced technologies such as Serial to Ethernet conversion, which allows legacy serial devices to communicate over an IP network. This feature is essential for companies looking to modernize their infrastructure without the need for a complete overhaul of existing equipment. By bridging the gap between old and new technologies, Lantronix ensures that organizations can extend the lifespan of their investments.

Another key characteristic of Lantronix Ethernet solutions is their robustness and security. Designed to withstand various environmental conditions, these devices are suitable for deployment in harsh environments, making them ideal for industrial applications. Additionally, robust encryption protocols and security features help safeguard sensitive data, ensuring that only authorized personnel can access the system.

Scalability is also a significant advantage of Lantronix Ethernet technology. As businesses grow and evolve, their networking needs often change. Lantronix products are designed to scale easily, allowing organizations to add new devices and functionality without disrupting existing operations. This flexibility enables businesses to adapt to new challenges and opportunities as they arise.

Moreover, Lantronix places a strong emphasis on ease of integration. With extensive support for various communication protocols and interfaces, their Ethernet solutions can be quickly and effectively integrated into existing systems, minimizing deployment time and maximizing efficiency.

In conclusion, Lantronix Ethernet technology represents a comprehensive solution for modern networking needs. With features such as remote management, serial communication capabilities, security, scalability, and ease of integration, Lantronix stands out as a leader in the connectivity landscape, empowering businesses to optimize operations and enhance productivity. Whether in industrial environments or remote locations, Lantronix Ethernet solutions deliver the reliability and performance required in today’s fast-paced digital world.