Lantronix Ethernet DisConnTime Inactivity Timeout, Packing Interval, Trailing Characters, Option

Page 62

Setup Mode: Channel Configuration

Table 7-9. Pack Control Options

 

 

 

 

 

 

 

 

 

 

 

 

 

Option

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

Packing Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 12 msec

 

 

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

Interval: 52 msec

 

 

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

Interval: 250 msec

 

 

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

Interval: 5 sec

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

Trailing Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

One

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

 

 

Two

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

 

 

Send Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Byte Send Character Sequence

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Immediately After Send chars

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Interval

Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is between successive network segments containing data. For alternate packing, the default interval is 12 ms.

Trailing Characters

In some applications, CRC, Checksum, or other trailing characters follow the end-of- sequence character; this option helps to adapt frame transmission to the frame boundary. The default setting is 00 (none).

Send Characters

‹If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2-byte sequence; if this option is not enabled, the unit interprets them independently. The default setting is 0 (disabled).

‹If Send Immediately After Characters is not set, any characters already in the serial buffer are included in the transmission after a "transmit" condition is found. If this option is set, the unit sends immediately after recognizing the transmit condition (sendchar or timeout). The default setting is 0.

Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.

DisConnTime (Inactivity Timeout)

Use this parameter to set an inactivity timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds.

WiBox2100E User Guide

62

Image 62
Contents WiBox2100E User Guide Lantronix Corporate Headquarters Technical Support Sales OfficesContents Setup Mode Server Configuration ContentsSetup Mode Advanced Settings List of Tables ComplianceList of Figures Serial Tunneling Infrastructure Network ExampleChapter Summary Using This GuidePurpose and Audience Using This Guide Additional DocumentationName Model Part Numbers IntroductionApplications Introduction Application ExamplesSerial Tunneling Network Ad Hoc Network Serial Tunneling InfrastructureAd Hoc WiBox Connection Configuration MethodsProtocol Support WiBox with EthernetHardware Address Wlan SettingsAddresses and Port Numbers IP AddressSerial Connector Pinouts DB9M DTE Serial ConnectorRS-485 2-Wire Pinouts WBX2100E Network InterfaceWiBox LEDs Ethernet Connector PinoutsLEDs Technical Specifications Hardware Address 00-20-4a Quick StartRequired Information IP Address Subnet Mask GatewayWPA Enabled Y/N WPA Key Type hex or passphrase? Installing and Configuring the WiBoxWEP Enabled Y/N? WEP Key 64 bit or 128 bit? Quick StartSyntax is SetZone IP address zone abbreviation WEP Using Device Installer To install the DeviceInstallerViewing the Current Configuration To view the WiBox’s configuration settingsWebPort Firmware UpgradeableRate Supports Wired Ethernet Maximum Baud RateQuick Start Web-Manager Configuration Accessing Web-Manager through a Web BrowserNetwork Configuration Web-Manager ConfigurationAuto-IP Automatic IP Address ConfigurationSelect Obtain IP address automatically Dhcp Host NameEthernet Configuration Server ConfigurationStatic IP Address Configuration Select Use the following IP configurationAdvanced To configure the WiBox’s device server settingsServer Configuration CPU Performance Mode Hostlist ConfigurationTo configure the WiBox’s hostlist Http Server PortRetry Settings Channel 1 and Channel 2 ConfigurationSerial Settings Host InformationChannel Port SettingsDisable Serial Port ProtocolPack Control Flush Input Buffer Serial to NetworkConnect Protocol Connection Settings TCPFlush Output Buffer Network to Serial At Time of DisconnectConnect Mode Passive Connection Connect Mode Active ConnectionEndpoint Configuration Common OptionsConnection Settings UDP Disconnect ModeDatagram Mode Datagram TypeDevice Address Table Wlan ConfigurationTo configure the WiBox’s Wlan settings Network Name Wireless Network ConfigurationWireless Network Security Network Type Select Infrastructure or Ad Hoc ChannelWPA Options Advanced SettingsWEP Options Updating Settings Applying DefaultsTelnet Connection Telnet or Serial Port Setup Mode ConfigurationAccessing Setup Mode To establish a Telnet connectionTo exit Setup Mode Exiting Setup ModeTelnet or Serial Port Setup Mode Configuration Serial Port ConnectionNetwork Mode Setup Mode Server ConfigurationServer Configuration Option IP AddressSet Gateway IP Address Change Telnet Configuration PasswordSetup Mode Server Configuration Netmask Number of Bits for Host PartDhcp Name Baudrate Setup Mode Channel ConfigurationChannel 1 Option Mode Option Interface ModeSetup Mode Channel Configuration Common I/F Mode Setting Binary HexFlow Control Option Hex Connect ModePort Number Port Numbers Reserved forIncoming Connection Connect Mode OptionConnect Mode Options ResponseActive Startup Incoming ConnectionResponse Manual Connection Manual Connection Address ExampleConnection To enable the hostlistAutostart Automatic HostlistModem Mode Datagram TypeFull Verbose 11. Modem Mode MessagesMessage Meaning Numeric ResponseModem Mode Commands Send the Escape Sequence +++ in Modem ModeModem Mode Function Command Auto Increment Source PortRemote IP Address Disconnect Mode OptionDisconnect Mode Options Remote PortFlush Mode Buffer Flushing Pack ControlTrailing Characters DisConnTime Inactivity TimeoutPacking Interval Send CharactersSend Characters Channel Port PasswordWlan Settings Telnet Terminal TypeSecurity Network Name SsidAdhoc Network Channel Fixed or Automatic Data Rate Transmission Data RateEnable Power Management TCP Keepalive time in seconds Setup Mode Advanced SettingsExpert Settings Option CPU Performance ARP Cache timeout in secondsDisable Monitor Mode at bootup Http Port NumberSecurity Settings Disable Web Setup Disable Port 77FE HexDisable Web Server Disable Echo PortsGenerally, one of two situations applies Channel 2 Configuration Default SettingsChannel 1 Configuration Enable Power Management Expert SettingsSecurity Settings Channel SecurityExit Configuration Mode Entering Monitor Mode via the Network Port Monitor ModeEntering Monitor Mode via the Serial Port Monitor Mode CommandsResponse Meaning Monitor ModeCommand Response Codes G0, G1, ....,Ge, GfObtaining Firmware Reloading Firmware Using Tftp Graphical User InterfaceUpdating Firmware ROM FileUpdating Firmware Network UpgradeUsing Tftp Command Line Interface To download new firmware from a computerWlan Country Setting Syntax is SetZone IP address zone abbreviationMethod Wireless BridgingConfiguring the WiBox in Bridging Mode Troubleshooting Problems and Error Messages TroubleshootingDiagnostic LED States Problem/Message Reason SolutionLater, there is only one setting for WiBox2100E only Caps Lock is not onTechnical Support Technical Support Europe, Middle East, and AfricaConversion Table Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorBinary to Hexadecimal Conversions Compliance Compliance InformationCanada Industry Canada Notice Regulatory InformationUSA Federal Communications Commission FCC Notice ComplianceAntenna Notice Europe R&TTE Directive 99/5/EC, Wireless NoticeAustralia & New Zealand Wireless Notice Exposure of Humans to RF FieldsCompliance Warranty

Ethernet specifications

Lantronix Ethernet technology is a pivotal component in modern networking, facilitating seamless communication and connectivity across a multitude of devices. Renowned for its reliability and innovation, Lantronix offers a diverse range of products and solutions that cater to various industries, from healthcare to industrial automation.

One of the standout features of Lantronix Ethernet devices is their ability to enable remote access and management of equipment. This is particularly beneficial in scenarios where physical access is limited or impractical. With secure remote management, organizations can monitor, control, and configure devices from virtually anywhere, streamlining operations and reducing downtime.

Lantronix Ethernet products utilize advanced technologies such as Serial to Ethernet conversion, which allows legacy serial devices to communicate over an IP network. This feature is essential for companies looking to modernize their infrastructure without the need for a complete overhaul of existing equipment. By bridging the gap between old and new technologies, Lantronix ensures that organizations can extend the lifespan of their investments.

Another key characteristic of Lantronix Ethernet solutions is their robustness and security. Designed to withstand various environmental conditions, these devices are suitable for deployment in harsh environments, making them ideal for industrial applications. Additionally, robust encryption protocols and security features help safeguard sensitive data, ensuring that only authorized personnel can access the system.

Scalability is also a significant advantage of Lantronix Ethernet technology. As businesses grow and evolve, their networking needs often change. Lantronix products are designed to scale easily, allowing organizations to add new devices and functionality without disrupting existing operations. This flexibility enables businesses to adapt to new challenges and opportunities as they arise.

Moreover, Lantronix places a strong emphasis on ease of integration. With extensive support for various communication protocols and interfaces, their Ethernet solutions can be quickly and effectively integrated into existing systems, minimizing deployment time and maximizing efficiency.

In conclusion, Lantronix Ethernet technology represents a comprehensive solution for modern networking needs. With features such as remote management, serial communication capabilities, security, scalability, and ease of integration, Lantronix stands out as a leader in the connectivity landscape, empowering businesses to optimize operations and enhance productivity. Whether in industrial environments or remote locations, Lantronix Ethernet solutions deliver the reliability and performance required in today’s fast-paced digital world.