Lantronix Ethernet manual Send the Escape Sequence +++ in Modem Mode, Auto Increment Source Port

Page 59

Setup Mode: Channel Configuration

If this sequence is not followed, the unit remains in data transfer mode.

 

 

 

7-6. Modem Mode Commands

 

 

 

 

 

Modem Mode

 

Function

 

Command

 

 

 

 

 

 

 

ATDTx.x.x.x,pppp or

 

Makes a connection to an IP address (x.x.x.x) and a remote port

 

ATDTx.x.x.x/pppp

 

number (pppp).

 

 

 

 

 

ATDTx.x.x.x

 

Makes a connection to an IP address (x.x.x.x) and the remote port

 

 

number defined within the unit.

 

 

 

 

 

 

 

 

ATD0.0.0.0

 

Forces the unit into Monitor Mode if a remote IP address and port

 

 

number are defined within the unit.

 

 

 

 

 

 

 

 

ATD

 

Forces the unit into Monitor Mode if a remote IP address and port

 

 

number are not defined within the unit.

 

 

 

 

 

 

 

 

ATDx.x.x.x

 

Makes a connection to an IP address (x.x.x.x) and the remote port

 

 

number defined within the unit.

 

 

 

 

 

 

 

 

ATH

 

Hangs up the connection (Entered as +++ATH ).

 

 

 

 

 

 

 

Enables or disables connections from the network going to the serial

 

 

 

port.

 

 

 

n=0 disables the ability to make a connection from the network to

 

ATS0=n

 

the serial port.

 

 

 

n=1-9 enables the ability to make a connection from the network to

 

 

 

the serial port.

 

 

 

n>1-9 is invalid.

 

 

 

 

 

 

 

Enables or disables character echo and responses.

 

ATEn

 

n=0 disables character echo and responses.

 

 

 

n=1 enables character echo and responses.

 

 

 

 

 

 

 

Enables numeric response or full verbose.

 

ATVn

 

n=0 enables numeric response.

 

 

 

n=1 enables full verbose.

 

 

 

 

Note: The unit recognizes these AT commands as single commands such as ATE0 or ATV1; it does not recognize compound commands such as ATE0V.

Send the Escape Sequence (+++) in Modem Mode

Send ‘+++’ in Modem Mode (Y) ? _

Disable or enable the WiBox’s ability to send the escape sequence. The default setting is Y (Yes) (send the escape sequence).

Auto Increment Source Port

Auto increment source port (N) ? _

Y (Yes) auto increment the source port. The WiBox increments the port number used with each new connection.

WiBox2100E User Guide

59

Image 59
Contents WiBox2100E User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersContents Contents Setup Mode Server ConfigurationSetup Mode Advanced Settings Compliance List of TablesSerial Tunneling Infrastructure Network Example List of FiguresChapter Summary Using This GuidePurpose and Audience Additional Documentation Using This GuideName Model Part Numbers IntroductionApplications Introduction Application ExamplesSerial Tunneling Network Serial Tunneling Infrastructure Ad Hoc NetworkWiBox with Ethernet Configuration MethodsProtocol Support Ad Hoc WiBox ConnectionIP Address Wlan SettingsAddresses and Port Numbers Hardware AddressDB9M DTE Serial Connector Serial Connector PinoutsWBX2100E Network Interface RS-485 2-Wire PinoutsWiBox LEDs Ethernet Connector PinoutsLEDs Technical Specifications IP Address Subnet Mask Gateway Quick StartRequired Information Hardware Address 00-20-4aQuick Start Installing and Configuring the WiBoxWEP Enabled Y/N? WEP Key 64 bit or 128 bit? WPA Enabled Y/N WPA Key Type hex or passphrase?Syntax is SetZone IP address zone abbreviation WEP To install the DeviceInstaller Using Device InstallerTo view the WiBox’s configuration settings Viewing the Current ConfigurationMaximum Baud Rate Firmware UpgradeableRate Supports Wired Ethernet WebPortQuick Start Accessing Web-Manager through a Web Browser Web-Manager ConfigurationWeb-Manager Configuration Network ConfigurationDhcp Host Name Automatic IP Address ConfigurationSelect Obtain IP address automatically Auto-IPSelect Use the following IP configuration Server ConfigurationStatic IP Address Configuration Ethernet ConfigurationAdvanced To configure the WiBox’s device server settingsServer Configuration Http Server Port Hostlist ConfigurationTo configure the WiBox’s hostlist CPU Performance ModeHost Information Channel 1 and Channel 2 ConfigurationSerial Settings Retry SettingsProtocol Port SettingsDisable Serial Port ChannelFlush Input Buffer Serial to Network Pack ControlAt Time of Disconnect Connection Settings TCPFlush Output Buffer Network to Serial Connect ProtocolConnect Mode Active Connection Connect Mode Passive ConnectionCommon Options Endpoint ConfigurationDisconnect Mode Connection Settings UDPDatagram Type Datagram ModeDevice Address Table Wlan ConfigurationTo configure the WiBox’s Wlan settings Network Type Select Infrastructure or Ad Hoc Channel Wireless Network ConfigurationWireless Network Security Network NameWPA Options Advanced SettingsWEP Options Applying Defaults Updating SettingsTo establish a Telnet connection Telnet or Serial Port Setup Mode ConfigurationAccessing Setup Mode Telnet ConnectionSerial Port Connection Exiting Setup ModeTelnet or Serial Port Setup Mode Configuration To exit Setup ModeIP Address Setup Mode Server ConfigurationServer Configuration Option Network ModeNetmask Number of Bits for Host Part Change Telnet Configuration PasswordSetup Mode Server Configuration Set Gateway IP AddressDhcp Name Baudrate Setup Mode Channel ConfigurationChannel 1 Option Common I/F Mode Setting Binary Hex Interface ModeSetup Mode Channel Configuration Mode OptionPort Numbers Reserved for Connect ModePort Number Flow Control Option HexResponse Connect Mode OptionConnect Mode Options Incoming ConnectionActive Startup Incoming ConnectionResponse Manual Connection Address Example Manual ConnectionHostlist To enable the hostlistAutostart Automatic ConnectionDatagram Type Modem ModeNumeric Response 11. Modem Mode MessagesMessage Meaning Full VerboseAuto Increment Source Port Send the Escape Sequence +++ in Modem ModeModem Mode Function Command Modem Mode CommandsRemote Port Disconnect Mode OptionDisconnect Mode Options Remote IP AddressPack Control Flush Mode Buffer FlushingSend Characters DisConnTime Inactivity TimeoutPacking Interval Trailing CharactersTelnet Terminal Type Channel Port PasswordWlan Settings Send CharactersSecurity Network Name SsidAdhoc Network Channel Transmission Data Rate Fixed or Automatic Data RateEnable Power Management TCP Keepalive time in seconds Setup Mode Advanced SettingsExpert Settings Option Http Port Number ARP Cache timeout in secondsDisable Monitor Mode at bootup CPU PerformanceSecurity Settings Disable Echo Ports Disable Port 77FE HexDisable Web Server Disable Web SetupGenerally, one of two situations applies Channel 2 Configuration Default SettingsChannel 1 Configuration Channel Security Expert SettingsSecurity Settings Enable Power ManagementExit Configuration Mode Monitor Mode Commands Monitor ModeEntering Monitor Mode via the Serial Port Entering Monitor Mode via the Network PortG0, G1, ....,Ge, Gf Monitor ModeCommand Response Codes Response MeaningROM File Using Tftp Graphical User InterfaceUpdating Firmware Obtaining Firmware Reloading FirmwareTo download new firmware from a computer Network UpgradeUsing Tftp Command Line Interface Updating FirmwareSyntax is SetZone IP address zone abbreviation Wlan Country SettingMethod Wireless BridgingConfiguring the WiBox in Bridging Mode Troubleshooting Problem/Message Reason Solution TroubleshootingDiagnostic LED States Problems and Error MessagesLater, there is only one setting for Caps Lock is not on WiBox2100E onlyTechnical Support Europe, Middle East, and Africa Technical SupportScientific Calculator Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableBinary to Hexadecimal Conversions Compliance Information ComplianceCompliance Regulatory InformationUSA Federal Communications Commission FCC Notice Canada Industry Canada NoticeExposure of Humans to RF Fields Europe R&TTE Directive 99/5/EC, Wireless NoticeAustralia & New Zealand Wireless Notice Antenna NoticeCompliance Warranty

Ethernet specifications

Lantronix Ethernet technology is a pivotal component in modern networking, facilitating seamless communication and connectivity across a multitude of devices. Renowned for its reliability and innovation, Lantronix offers a diverse range of products and solutions that cater to various industries, from healthcare to industrial automation.

One of the standout features of Lantronix Ethernet devices is their ability to enable remote access and management of equipment. This is particularly beneficial in scenarios where physical access is limited or impractical. With secure remote management, organizations can monitor, control, and configure devices from virtually anywhere, streamlining operations and reducing downtime.

Lantronix Ethernet products utilize advanced technologies such as Serial to Ethernet conversion, which allows legacy serial devices to communicate over an IP network. This feature is essential for companies looking to modernize their infrastructure without the need for a complete overhaul of existing equipment. By bridging the gap between old and new technologies, Lantronix ensures that organizations can extend the lifespan of their investments.

Another key characteristic of Lantronix Ethernet solutions is their robustness and security. Designed to withstand various environmental conditions, these devices are suitable for deployment in harsh environments, making them ideal for industrial applications. Additionally, robust encryption protocols and security features help safeguard sensitive data, ensuring that only authorized personnel can access the system.

Scalability is also a significant advantage of Lantronix Ethernet technology. As businesses grow and evolve, their networking needs often change. Lantronix products are designed to scale easily, allowing organizations to add new devices and functionality without disrupting existing operations. This flexibility enables businesses to adapt to new challenges and opportunities as they arise.

Moreover, Lantronix places a strong emphasis on ease of integration. With extensive support for various communication protocols and interfaces, their Ethernet solutions can be quickly and effectively integrated into existing systems, minimizing deployment time and maximizing efficiency.

In conclusion, Lantronix Ethernet technology represents a comprehensive solution for modern networking needs. With features such as remote management, serial communication capabilities, security, scalability, and ease of integration, Lantronix stands out as a leader in the connectivity landscape, empowering businesses to optimize operations and enhance productivity. Whether in industrial environments or remote locations, Lantronix Ethernet solutions deliver the reliability and performance required in today’s fast-paced digital world.