14 | 12 |
13 | 11 |
14 | 11 |
13 | 12 |
13 | 11 |
14 | 12 |
| Index Pulse |
| Home Switch |
| Negative Limit Switch |
Figure 7.8: Homing on the Home Switch and Index Pulse - Negative Initial Move
Methods 15 and 16: Reserved
These methods are reserved for future expansion of the homing mode.
Methods 17 to 30: Homing without an Index Pulse
These methods are similar to methods 1 to 14 except that the home position is not dependent on the index pulse but only Dependent on the relevant home or limit switch transitions. For example methods 19 and 20 are similar to methods 3 and 4 as shown in the following diagram.
19
19
20
20
Home Switch
Figure 7.9: Homing without an Index Pulse
Methods 31 and 32: Reserved
These methods are reserved for future expansion of the homing mode.
46 | MDrivePlus CANopen R020507 |